manualshive.com logo in svg
background image

ZG2 Short Manual

Tutorial

This chapter shows step by step how to set up the ZG2 profile sensor to perform a 
measurement. Below you can find the 7 steps to follow. More detailed description of 
each step is given then on the following pages.

1) Initialization (optional):

Initialize the sensor as a first step to start with default values.

2) Mount the sensor head:

Mount the sensor head that you can see the yellow profile line on the LCD screen.

3) „Teach“ a profile:

The stored profile is used for the setting of the measurement region and position
correction.

4) Select a measurement item:

The ZG2 has19 different measurement items and 1 calculation item for flexible 
inspection of all kinds of measurements.The ZG2 can perform up to 8 tasks at the
same time without increase of measurement cycle time.

5) Set the measurement region for the measurement item:

The functioning of measurement items is based on characteristic points which are
defined by a horizontal or vertical regions along the profile line.

6) Optimize the image settings regarding cycle time and accuracy:

The ZG2 has multiple modes for the control of the laser power as well as multiple 
filters for image improvement.

7) Setup position compensation (optional):

The ZG2 can compensate horizontal, vertical and slope postion variations.

T

u

to

ri

a

l

Содержание ZG2 Series

Страница 1: ...Smart Sensor 2 D Profile Measuring Sensor ZG2 Short Manual Setting tutorial V1 0...

Страница 2: ...DS8T ZG2 WDS3VT 0 5m or 2m cable length Data Storage Unit ZG2 DSU41 ZG2 DSU11 Sensor Controller ZG2 WDC41A ZG2 WDC11A Parallel Output Unit ZG RPD41 ZG RPD11 RS232 cable ZS XPT2 for PLC ZS XRS2 for PC...

Страница 3: ...function is active 4 Trigger Indicator turns on while trigger input is active 5 LCD Screen color graphic LCD 6 Menu Switch selects standard or expert menu 7 Mode Switch selects set or run mode 8 Cont...

Страница 4: ...ZG2 Short Manual Overview Overview...

Страница 5: ...an be attached to the left side Channel assigment is always as shown above regardless of the presence of a ZG2 DSUxx The Data Storage Unit ZG2 DSUxx can be used for logging measurement results logging...

Страница 6: ...ion 4 Select a measurement item The ZG2 has19 different measurement items and 1 calculation item for flexible inspection of all kinds of measurements The ZG2 can perform up to 8 tasks at the same time...

Страница 7: ...After initialization the laser power mode is set to Multi Mode s page xx and the measurement item for task 1 to Height1 On the LCD screen you can see the profile in real time The red cross and the va...

Страница 8: ...bank can be changed in run mode via digital input terminal RS232 or USB Move the sensor head until the profile can be seen on the LCD screen in RUN mode The red cross and the mm value on the screen re...

Страница 9: ...tought profile is stored until the next teaching also if the sensor is powered down After teaching 2 additional menu items appear on the screen above 3 SENS 4 CORECT Remark In the menu 2 IMAGE you can...

Страница 10: ...on appears Here you can select one of the 8 tasks by pushing the corresponding number key and or using the cursor keys and pressing the SET key The selected task also is also shown in the bottom line...

Страница 11: ...ment region automatically Press key 1 for the selection of 1ITEM Now you can select a new item from a set of 19 different items Use the number and or the cursor keys for the selection of the desired i...

Страница 12: ...he custom setting for finetuning in a second step If the menu switch is set to STD the 4 AUTO menu is not available Please select 4 AUTO by pressing the key 4 Now the TRIMMING screen is displayed You...

Страница 13: ...reen The result is shown in red color if the result is above the high threshold or below the low threshold In this case also the corresponding task LED is off If the result is between the high and low...

Отзывы: