background image

13

EN

11 Trouble shooting

Note:

If a malfunction has occurred and you need to repair your 
unit, all settings and measurement results are deleted. We 
recommend you to record measurement results.

Phenomenon

Cause

Rectification

Blinks or appears

continuously.

Battery weak or 

exhausted.

Insert a new 3V lithium 

battery type CR2032 

(refer to Chapter 9.1).

Nothing is 

displayed.

Polarities of 

battery (+ and -) 

aligned in wrong 

directions.

Insert battery in correct 

alignment (refer to 

Chapter 9.1).

Battery weak or 

exhausted.

Insert a new 3V lithium 

battery type CR2032 

(refer to Chapter 9.1).

Energy saving 

function active.

Press either of 

 

or  

(refer to Chapter 

7.2).

Displayed values 

are incorrect.

The unit is 

attached 

incorrectly.

Follow instructions (refer 

to Chapter 6.2).

You are walking 

at inconsistent 

pace.

Cases where the unit may 

not be able to count steps 

accurately (refer to 

Chapter 7.2).

Settings are 

wrong.

Change settings (refer to 

Chapter 5.1).

The display is unusual or the buttons 

do not operate normally.

Remove the battery then 

insert it again (refer to 

Chapter 9.1).

HJ-203-E_A_M.book  13 ページ  2011年12月19日 月曜日 午後3時40分

Содержание Walking style III

Страница 1: ...Step counter Walking style Instruction Manual 1 Mode d emploi 17 Gebrauchsanweisung 33 Manuale di istruzioni 49 IM HJ 203 E 02 10 2011 9062598 0B EN FR DE IT...

Страница 2: ......

Страница 3: ...ry it Use it every day for an easy way to monitor your health The OMRON Walking style III Features Calories burned Fat burned The intensity of your walking is measured and the amount of calories and f...

Страница 4: ...should get in your eyes immediately rinse with plenty of clean water Consult a doctor immediately If battery fluid should get on your skin or clothing immediately rinse with plenty of clean water Do...

Страница 5: ...nit with a thin sturdy stick that will not break easily Note Do not press the button with a sharp point This could cause damage After the following display the hour flashes Note If no settings are mad...

Страница 6: ...ber of steps e g 7 1 meter divided by 10 steps 0 71 m This completes the setup Adjusting the setting 1 Press the SET button on the back of the unit with a thin sturdy stick that will not break easily...

Страница 7: ...lip the strap to the edge of your bag Neck 1 Attach a commercially available string strap or key cord to the unit and hang it from your neck Note A neck strap is not included 6 3 Actual use of the OMR...

Страница 8: ...the displays rotates when using the activity mode 2 Start walking The display changes with each press of to display the step count distance calories burned fat burned and the time in that order 3 Pre...

Страница 9: ...ked during a day Calories display Additional energy burned during a day Resting metabolism additional energy burned total energy consumption for one day Assists you with your diet Fat burned during a...

Страница 10: ...efined walking event Time display Step taken during the self defined walking event Distance walkedduring the self defined walking event Additional energy burned during the self defined walking event R...

Страница 11: ...d or placed upside down or if the main unit is perpendicular to the ground Irregular movement When the unit is placed in a bag that moves irregularly because it hits your foot or clothes When the unit...

Страница 12: ...view the measurement results The display changes with each press of as shown below Keep pressed to automatically change the display until the current display is displayed Press to return to the curre...

Страница 13: ...d battery is for trial use This battery can run out within 1 5 years 9 1 Replacing the battery 1 Loosen the screw of the battery cover on the back of the unit and remove the battery cover by pulling i...

Страница 14: ...ations not approved by OMRON HEALTHCARE will void the user warranty Do not subject the unit to strong shocks or vibrations drop it step on it or leave it at an angle Do not immerse the unit or any of...

Страница 15: ...rt battery in correct alignment refer to Chapter 9 1 Battery weak or exhausted Insert a new 3V lithium battery type CR2032 refer to Chapter 9 1 Energy saving function active Press either of or refer t...

Страница 16: ...R2032 Battery life Approx 1 5 years when used for 4 hours a day Note Supplied battery is for trial use This battery can run out within 1 5 years Measurement range Steps 0 to 99 999 steps Distance walk...

Страница 17: ...Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal This product does no...

Отзывы: