INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
1.To ensure safety, be absolutely sure to follow the instructions
below:
(1) NEVER use the product in an environment where combustible
or explosive gas is present.
(2) If abnormal odor or noise occurs, if the outside surface is
excessively hot, or if the product emits fume, immediately
stop the operation and power OFF the product.
(3) IF the product is accidentally dropped or damaged,
immediately power it OFF and contact your nearestOMRON
representative for technical support.
6.Part 15 of the FCC Rules
For a Class A digital device or peripheral, the instructions furnished
the user shall include the following or simillar statement, placed in
a prominent location in the text of the manual:
NOTE : This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment genarates,
user, and can radiate radio frequency enegy and, if not installed and
used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
© OMRON Corporation
2003
All Rights Reserved.
PRECAUTIONS ON SAFETY
■
Dimensions
* Be sure to limit the tightening torque for the M4 screws
to 1.2 N-m or less.
(Unit: mm)
-- Document conventions -- symbols (signal words) and their
meanings
Throughout this document, the signal and associated symbols
(icons) are used to allow the operator to use this unit. The
statements marked with signal words describe important
safety-related instructions that must be strictly observed. The
symbols and meanings are as given below:
Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury or in property damage.
CAUTION
CAUTION
Never use AC adapter other than V600-A20.
If you use other AC adapter, it may cause
malfunction, injury and fire.
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
1.About environments of installation
Do not install or leave the product to a location such as:
(1) Location subjected to direct sunlight
(2) Location where corrosive gas, dust, metal dust, salty air is
present
(3) Location where the operating temperature can exceed or drop
below a range defined in the specification
(4) Location where temperature change is great, and can lead to
dew condensation
(5) Location with higher humidity, and can lead to dew
condensation
(6) Location where vibration or impact whose magnitude greater
than specified can be directly transmitted to the product proper
(7) Location where splash pf water, oil or chemical product is
present
2.About installation
(1) This product operators on the 125kHz frequency band to
communicate with an ID tag. Certain transceivers, motors,
monitors, and power supplies (power ICs) can emit a radio
frequency wave (noise) that can adversely affect
communications with an ID tag. When planning to use the
product near such a source, study the possible result in
advance.
(2) To minimize the possible noise interference, earth-ground
(class D earth work) a metal object that will be located around
the product.
3.About wiring work
(1) Before starting a wiring work or disconnecting a cable, be sure
to power OFF the product
(2) Do not run the cable for the product in a conduit common to a
high voltage line and a power supply line.
(3) To avoid static-induced failure, wear a wrist band or equivalent
means to release a static charge before touching a terminal or a
signal line within a connector.
4.About thread glue
(1) A thread glue can deteriorate and lead to crack on a resin part.
Thus, do not apply a thread glue to the threading on a resin
part or to resin-made washers.
5.About cleaning
(1) NEVER use an organic solvent such as thinner or benzene, as
it will attack resin components or case coating.
■
Interface specifications
1
8
1
11
Characteristic
Specification
Connector
specification
9-pin D-SUB connector socket
Communication
standard
RS-233C
Synchronization
Asynchronous mode, start-stop synchronization
Communication
control standard
OMRON original 1:1 protocol
Band rate (fixed)
9,600 bps
Character format
(fixed)
Start bit Data bit Parity bit Stop bit
Total
Even
Error control
Even parity
■
RS-232C connector pin arrangement
No.
1
2
3
4
5
6
7
8
9
Signal name
Send data
Receive data
Request send
Clear to send
Signal ground
Symbol
SD
RD
RS
CS
SG
Comment
Normally ON
Direction
Input
Output
−
(1) Connector pin number is writen in D-SUB connector.
Cable
PVC (oil-resistant)
Filler resin
Epoxy resin
Case material
ABS resin
■
General specifications
Characteristic
Supply voltage
Protection rating
Insulation
resistance
Dielectric
Shock resistance
Vibration
resistance
Weight
Ambient
humidity
Ambient
temperature
Current consumption
Specification
5VDC,
+
5%,
−
5% (supplied from V600-A20)
200 mA max
IP67 (IEC 60529), IP67g (JEM 1030)
(The connector is not resistant to water or oil.)
300m/s
2
, 3 times each in 6 directions
About 210g (Cable length is 2m)
1000V AC (50/60Hz, for 1 min.)
leak current consumption 1mA max.
(between all connector terminals and case)
50MΩ
min. (500V DC for appliance)
(between all connector terminals and case)
Operating: 25 to 85%RH, Storage: 25 to 95%RH
(No freezing, No dew condensation)
Operating:
−
10
℃
to
+
55
℃,
Storage:
−
25
℃
to
+
65
℃
(No freezing, No dew condensation)
10 to 150Hz, 1.5mm double amplitude,
with 4 sweeps of 8min each in 3 directions
Applied standards R&TTE / FCC Part15 Subpart C
Carrier detection
CD
Internally connected to DR
−
Data set ready
DR
Output
−
−
Internally connected
to each other
OMRON Corporation
Suitability for Use
EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0 Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A
Phone:1-847-843-7900 Telephone Consultation
1-800-55-OMRON Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE LTD
83 Clemenceau Avenue,#11-01 UE Square,Singapore 239920
Phone : 65-6-835-3011 /Fax :65-6-835-2711
n
THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or
regulations that apply to the combination of the products in the customer's
application or use of the product.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
10
5
5
28
±
0.1
28
±
0.1
27
±
0.2
2-M4 OR 4.5dia.
CENTER OF COIL
MOUNTING SCREW HOLES
15
23
11
13
18
5
32
45.5
45
14dia.
20
6
27
53
40
OPERATION INDICATOR
4-R1
BUSH
2-4.5dia.(MOUNTING HOLES)
2-10dia.
When installed from the reverse side,
insert the attached nuts into the holes "A".
ATTACHED
NUTS FOR M4
A
VINYL INSULATED ROUND CODE 6dia.
STANDARD LENGTH 2M
VINYL INSULATED FLAT CODE (1.8dia.x2)
STANDARD LENGTH 0.19M
CONNECTOR:EIAJ RC5320A JSAP2(RECEPTACLE)
9PIN D-SUB CONNECTOR
Model
V700-HMD11
ID System Reader/Writer
V700-HMD11-R
*1) In dimensions of V700-HMD11-R, the cord is different from V700-HMD11.
The cord of V700-HMD11-R is as follow;
" ROBOT INSTRUMENTAL CABLE 5.7dia. STANDARD LENGTH 2m"