18
Frequency inverters
Varispeed V7 IP65
200 V
400 V
A
Line filters *
* V7 IP65 types are built-in filter inverters.
Specifications
Model
1x200 V
0.55 Kw
3.0 A
CIMR-V7TZB0P405
1.1 Kw
5.0 A
CIMR-V7TZB0P705
1.5 Kw
8.0 A
CIMR-V7TZB1P505
2.2 Kw
11.0 A
CIMR-V7TZB2P205
Specifications
Model
3x400 V
0.55 Kw
1.8 A
CIMR-V7TZ40P405
1.1 Kw
3.4 A
CIMR-V7TZ40P705
1.5 Kw
4.8 A
CIMR-V7TZ41P505
2.2 Kw
5.5 A
CIMR-V7TZ42P205
3.0 Kw
7.2 A
CIMR-V7TZ43P005
4.0 Kw
9.2 A
CIMR-V7TZ44P005
Inverter
Line filter
Voltage
Model CIMR-V7AZ
Schaffner
Rasmi
Rated current (A)
Weight (kg)
3-Phase 200 VAC
20P1 / 20P2 / 20P4 / 20P7
3G3MV-PFI2010-SE
3G3MV-PFI2010-E
10
0.8
21P5 / 22P2
3G3MV-PFI2020-SE
3G3MV-PFI2020-E
20
1.0
24P0
3G3MV-PFI2030-SE
3G3MV-PFI2030-E
30
1.1
25P5 / 27P5
-
3G3MV-PFI2050-E
50
2.3
Single-Phase 200 VAC
B0P1 / B0P2 / B0P4
3G3MV-PFI1010-SE
3G3MV-PFI1010-E
10
0.6
B0P7 / B1P5
3G3MV-PFI1020-SE
3G3MV-PFI1020-E
20
1.0
B2P2
3G3MV-PFI1030-SE
3G3MV-PFI1030-E
30
1.1
B4P0
3G3MV-PFI1040-SE
3G3MV-PFI1040-E
40
1.2
3-Phase 400 VAC
40P2 / 40P4
3G3MV-PFI3005-SE
3G3MV-PFI3005-E
5
1.0
40P7 / 41P5 / 42P2
3G3MV-PFI3010-SE
3G3MV-PFI3010-E
10
1.0
40P4
3G3MV-PFI3020-SE
3G3MV-PFI3020-E
15
1.1
45P5 / 47P5
3G3MV-PFI3030-SE
3G3MV-PFI3030-E
30
2.3
Varispeed V7
19
B
Communication cards
C
PLC option card
D
Option frame accessory for V7 IP65
Type
Model
1
1.
Option frame accessory is needed for V7 IP65 types when communications option units are used.
Description
Function
C
om
m
un
ic
at
io
n
op
tio
n
bo
ar
d
3G3MV-PDRT2
DeviceNet option card
2
2.
For V7 IP65 types with DeviceNet communication, SI-N1/V7 should be used.
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through DeviceNet communication with the
host controller.
SI-P1/V7
PROFIBUS-DP option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through PROFIBUS-DP communication
with the host controller.
SI-S1/V7
Can open option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through CANopen communication with the
host controller.
3G3MV-PCORT21
Can open gateway
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through CANopen communication with the
host controller.
SI-T1/V7
MECHATROLINK-II
option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through MECHATROLINK-II communica-
tion with the host controller.
• High speed motion bus.
• Host controller: TrajeXia, MCH or MP series.
3
3.
Please refer to TrajeXia, MCH or MP series section for host controller technical information.
Type
Model
1
1.
Option frame accessory is needed on V7 IP65 types when PLC option unit is used.
Description
Function
P
LC
o
pt
io
n
3G3MV-P10CDT-E
3G3MV-P10CDT3-E
PLC option
• Full PLC featrues, wireless installation and seamless access to the inverter parameters and
analogue/digital inputs and outputs.
• Standard OMRON tools can be used for programming
• Calendar / clock
PLC option with
RS 422/485
• Same features as standard models with RS 422/485 support.
Type
Model
Description
Function
O
pt
io
n
fr
am
e
V7TZ-FR1
Option frame
• Frame accessory is needed when communication option unit or PLC option unit are used
with Varispeed V7 IP65.
Varispeed V7