91
RFID System
User's Manual
Section 3
V600 Commands
Section 3
Commands
WRITE (WT)
This command writes data to the RF Tag. If the RF Tag is not in the interrogation zone, an error
response (end code: 72 = RF Tag non-existent) will be returned.
Processing Area Number: 1
Processing Area Number: 2
Data setting
Sets the code format used to send responses for write data.
A: ASCII
H: Hexadecimal
When multiple processing areas are used, ASCII and hexadecimal can be specified at the same
time within a single command frame.
Processing area number
setting
Specifies the processing area number.
Setting range: 1 to 9, A (A = 10)
Write area start address
Specifies the start address of the area in the RF Tag to be written to in 4-digit hexadecimal.
Setting range: 0000 to FFFF hex
When multiple processing areas are used, specify the areas in order starting from the smallest
address. The same area cannot be specified twice.
Number of write bytes
When multiple processing areas are used, specifies the number of bytes to be written to the RF Tag
in 2-digit hexadecimal. The maximum number of bytes that can be written at one time is 256 bytes,
as follows:
•
ASCII: 256 bytes (256 characters)
•
Hexadecimal: 256 bytes (512 characters)
Setting range: 01 to FF hex
When multiple processing areas are used, set so that the total number of bytes to be written for all
areas is within 256 bytes, as follows:
Area (1) bytes +...+ Area (N) bytes
≤
256 bytes
Write data
Specifies the write data from the RF Tag.
The characters in ASCII indicate the number of write bytes and the characters in hexadecimal indi-
cate the number of write bytes x 2.
End code
Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to
Command
×
×
W
T
×
×
A / H
1
×
×
2
1
1
4
2
C R
n
×
×
Command
code
Data
setting
Processing
area
number
setting
Write data
Write area
start address
Terminator
×
×
W
T
×
×
A / H
2
×
×
2
1
1
4
2
…
×
×
n
2
C R
A / H
1
×
×
×
×
×
×
4
2
…
×
×
n
Command
code
Data
setting
Processing
area
number
setting
Number of
write bytes
Write area
start address
Area (1) setting
Write data
Terminator
Area (2) setting
Data
setting
Number of
write bytes
Write area
start address
Write data
Response
W
T
0
0
2
2
2
C R
Command
code
Terminator
End code