manualshive.com logo in svg
background image

Model

V680-HAM42-PRT

PROFIBUS ID Slave

Observe the following precautions to ensure safe usage of the product.
 1. Installation and Storage Environment

Do not use the Products in environments subject to oil.

 2. Installation and Removing

Do not connect the power supply in reverse.

Do not never use the AC power supply.

Do not perform wiring incorrectly or short-circuit the load. Doing so may 

result in rupture or damage from burning.

Do not install the Products near any equipment that generates a large 

amount of heat (such as heaters,transformers, and large-capacity 
resistors).

Make sure that all cable connectors with locking mechanisms are locked 

before using the cable.

If multiple Antennas are mounted near each other, communications 

performance may decrease due tomutual interference. Refer to Reference 
Data in Section 7 Appendices of User’s Manual and check to make sure 
there is no mutual interference.

To remove the Unit from DIN rail, catch a tool on the hook and gently 

PRECAUTION FOR SAFE USE

 1. Installation and Storage Environment

Do not use or store the Product in the following locations.

Locations subject to corrosive gases, dust, dirt, metal powder, or salt.

Locations where the specified ambient temperature and ambient humidity 

range is exceeded.

Locations subject to extreme temperature changes that may result in 

condensation.

Locations where the product would be directly subjected to vibration or 

shock exceeding   specifications.

Locations where liquid and foreign body might invade in this product 

such as outside boards.

・Locations subject to contact with water, oil, or chemicals.

2. Installation

The Products communicate with Tags using the 13.56-MHz frequency 

band. Some transceivers,   motors, inverters, and switching power 
supplies generate noise that can affect communications with   the Tags 
and cause errors. If such devices are located near the Tags, always test 
operation in   advance to confirm whether the system will be affected.

Observe the following precautions to minimize the effects of normal noise.

(1)Ground all metal objects in the vicinity of the Products to 100 

Ω

 or 

less.

(2)Do not use the Products near high-voltage or high-current lines.

Always bundle the cables connected to the power supply terminals and 

the ground terminal and   connect the enclosed ferrite core 
(ZCAT2032-0930 manufactured by TDK).

Do not pull on the cables with excessive strength.

Make sure that the ID Slave is provided with sufficient ventilation space.

Please do not connect with the PROFIBUS connector excluding a 

PROFIBUS cable.

Turn OFF the Controller power supply before mounting or removing a 

connector.

3. Using

Make sure the power supplied by the DC power supply unit is within the 

rated power supply voltage    (24 VDC +10%/−15%) before using the 

Product.

PRECAUTION FOR CORRECT USE

(Unit 

 mm)

Node Address Switch

remove the Unit.

3. Using

・Do not attempt to disassemble, repair, or modify any Product.

・Do not allow water or pieces of wire to enter from openings in the 

case. Doing so may cause fire or electric shock.

・Turn OFF the Controller power supply before mounting or 

removing an Antenna.

・If an error is detected in any Product, immediately stop operation 

and turn OFF the power supply. Consult with an OMRON 

representative.

4. Cleaning

・Do not clean the Products with paint thinner, benzene, acetone, or 

kerosene.

5. Disposing

・Dispose of the Products as industrial waste.

Specifications

Supply voltage

24 VDC (-15% to +10%)

 

ripple

(p−p)

10% is contained.

Power consumption 4W max
Ambient operating
 temperature

At operation

-10 to 55

No freezing.There is no dew formation.

At preservation

-25 to 65

No freezing.There is no dew formation.

At operation,At preservation

25 to 85

RH

No freezing.There is no dew formation.

  The ambient temperature of 85%RH is 40

 or less

.

Insulation resistans 20M

Ω

 min.

with 500 VDC megohmmeter

Between power supply terminals (except for grand) and casing
Between power supply terminals (except for grand) and grand

Withstand voltage 1000VAC,50/60Hz,1min

Between power supply terminals (except for grand) and casing
500VAC,50/60Hz,1min
Between power supply terminals (except for grand) and grand

Vibration resistanse 10 to 150 Hz, double amplitude: 0.2 mm, Acceleration: 150m/s

2

,

with 10 sweep of 8 min each in 3 directions

Shock resistance

Mechanical durability: 150m/s

2

, 3times each in 6 directions

Dimensions

65

 × 

65 

×

 65 mm (excluding protruding parts)

Degree of protection IEC60529Standard  IP20  (Panel-mounting) 

Material

PC/ABS resin

Weight

Approx. 150 g

Mounting method

DIN rail

Ambient operating
 humidity

Accessory

Ferrite core (TDK:ZCAT2032-0930) 

1 pcs  

C

onnector (PHOENIX CONTACT:FKC2.5/5-ST-5.08-RFAUM) 

1 pcs

Instruction Sheet  1 sheet
Description of Regulations and Standard 1 sheet

Description

Setting method

Characteristic

Setting range

Setting method

Left rotary switch is a grider of ten.

Right rotary switch is a grider of one. 

00

63

The setting in the factory when shipping it is 00.

The node address of PROFIBUS is set.

Mode Switch

The operation mode is set.

Name

The setting is prohibited.(It becomes a mode setting error.)

No.

0

1
2
3
4

5

6

7
8

9

Run mode

The setting is prohibited.(It becomes a mode setting error.)

NOISE

TEST

RUN


The setting is prohibited.(It becomes a mode setting error.)

Normal operation.
Test lead execution on page 1

of 4 bytes

The environment measurement of the noise in the antenna surroundings .

Abbreviation

Description

Communication Test

Noise measurement

The setting is prohibited.(It becomes a mode setting error.)
The setting is prohibited.(It becomes a mode setting error.)

The setting is prohibited.(It becomes a mode setting error.)


The setting is prohibited.(It becomes a mode setting error.)

SAFRTY PRECATIONS

5

1

9

6

1
2
3
4
5

CNTR-P

RxD/TxD-P

DGND

Name

PINNo.

6
7
8
9

VP

RxD/TxD-N

Control signal for repeaters (direction control) 

Receive/Transmit data - plus (B wire)

Data ground (reference potentia for VP)

Description

Supply voltage of the terminator resistance (5Vdc)

Receive/Transmit data - minus (A wire)

1.5

16

20

10

6

18

21.5

42

18.25

32.5

5.1

22.6

3-SWITCH

CONNECTOR

12-OPERATION

INDICATOR

65

5 5 5

65

4

12

CONNECTOR

CONNECTOR

65

28.5

(3.7)

(12)

35.2

5

4.8

9.5 dia.

(6.1

)

Meaning of Signal Words

Warning

WARNING

These Products are not designed to be used either directly 
or indirectly in applications that detect human presence for 
the purpose of maintaining safety. Do not use these 
Products as a sensing means for protecting human lives.

InIndicates a potentially hazardous situation 

which, if not avoided, will result in minor or 

moderateinjury, or may result in serious injury 

or death. Additionally, there may be significant

property damage.

WARNING

Meaning of Alert Symbols

Indicates general prohibitions for which there is no 

specific symbol.

1. Rating performance

2. Installation

3. Name and functions

4. Dimensions

Recommended DIN Track
OMRON PFP-100N2
(track length: 1m)

1. First hook the ID Slave on part A, then press the ID Slave in direction B to 

mount it to the DIN Track.

2. To disconnect the ID Slave from the DIN Track, pull the mounting hook 

downwards, and then lift the ID Slave upwards.

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

V680-HAM42-PRT

OMRON

OMRON Corporation

SOURCE : 24VDC 0.2A

MADE IN JAPAN

X10 1

X10 0

MS

BF

T/R

NORM/ERR

7

3

6

2

5

1

4

0

NODE ADDRESS

MODE

RUN

TEST

NOISE

(2)Data indicator (2colored LED)

DATA:DATA code (Green)
ERC:Error code (Red)

(3)Mode Switch

regulates function mode

(4)Node Address Switch

node address setting (00

63)

(7)PROFIBUS  connector

Connect to the PROFIBUS Master Unit

(5)Power supply terminal

24VDC power supply is supplied.
Attached connector type:FKC2.5/3-ST-5.08-RF
(PHOENIX CONTACT)
Use wire size of AWG 12-22 with strip length of 
10 mm. Recommended source is S8VS-03024 
(OMRON).

(6)Antenna connector

1
2
3

GND

0V

+24V

Name

1
2

PIN No.

3

Ground terminal

24 VDC input terminals

Function

(1)Status indicator

MS:Machine status
BF:Bus Failure
T/R:Transmission status
NORM/ERR:Communication status

Connectable Antennas

V680-HS63-W
V680-HS65-W

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

V680-HAM42-PRT

OMRON

OMRON Corporation

SOURCE : 24VDC 0.2A

MADE IN JAPAN

X10 1

X10 0

MS

BF

T/R

NORM/ERR

7

3

6

2

5

1

4

0

NODE ADDRESS

MODE

RUN

TEST

NOISE

DIN Track

End Plate

End Plate

Mounting Hook

© OMRON Corporation  

2011

  All Rights Reserved.

INSTRUCTION SHEET

Thank  you  for  selecting  OMRON  product.  This  sheet  pri-

marily  describes  precautions  required  in  installing  and

operating the product.

Before operating the product, read the sheet thoroughly to

acquire sufficient knowledge of the product. For your con-

venience, keep the sheet at your disposal.

Cable length

Radiated magnetic
field strength

13,56MHz

maximum 20 dBμA/m at 10 meters

Suitability for Use

s

Omron Companies shall not be responsible for conformity with any standards, 
codes or regulations which apply to the combination of the Product in the 

Buyer’s application or use of the Product. At Buyer’s request, Omron will 

provide applicable third party certification documents identifying ratings and 
limitations of use which apply to the Product. This information by itself is not 
sufficient for a complete determination of the suitability of the Product in 
combination with the end product, machine, system, or other application or 
use. Buyer shall be solely responsible for determining appropriateness of the 

particular Product with respect to Buyer’s application, product or system. 

Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 

SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND 

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 

EQUIPMENT OR SYSTEM.

S

ee also Product catalog for Warranty and Limitation of Liability.

O c t ,   2 0 1 4

D

OMRON Corporation

      Industrial Automation Company

 Contact:  www.ia.omron.com

Tokyo, JAPAN

OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A.

Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 

Alexandra Technopark, 

Singapore 119967

Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower, 

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON EUROPE B.V.
Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen, Germany

Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

Regional Headquarters

Manu

facturer:

  Omron Corporation,
  Shiokoji Horikawa, Shimogyo

-ku,

  Ky

oto 600-8530 JAPA

N

TR

ACEABILITY INFORMA

TION:

Importe in EU

:

  Omron Europe B.V.
  

Wegalaan 67-69

  2132 JD Hoofddorp,
  The Netherlands

Отзывы: