84
SEC
TI
O
N
6
M
a
inte
na
nc
e
a
nd Ins
p
e
c
tion
Electromagnetic Inductive RFID System
User's Manual
SECTION 6
Appendices
Maintenance and Inspection
To maintain the CF Reader/Writer in optimum condition, daily or periodic inspections are required.
The CF Reader/Writer mainly consists of semiconductor components, which have a long life. The following
malfunctions, however, may occur depending on the environment and operating conditions.
(1) Deterioration of elements due to overvoltage or overcurrent
(2) Deterioration of elements due to long-term stress caused by operation in locations with high ambient
temperatures
(3) Deterioration of insulation or imperfect connector contact due to humidity or dust
(4) Imperfect connector contact or corrosion of elements due to corrosive gas.
Inspection item
Inspection details
Criteria
Required equip-
ment
Fluctuation in power supply
voltage
Check at the power supply terminal block
that the criteria area satisfied.
Within the specifications for power sup-
ply voltage.
Tester
Check whether instantaneous power fail-
ure occurs frequently and whether volt-
age fluctuates considerably.
Within allowable voltage fluctuation
range.
Power supply
analyzer
Ambient envi-
ronment
Temperature
Check if within specifications.
Within the specifications.
Lowest tempera-
ture thermometer
Hygrometer
Humidity
Vibration and
shock
Check for vibration or shock from
machines.
Dust
Check for adherence or sedimentation of
dust or foreign matter.
No dust or foreign matter.
Corrosive gas
Check for discoloration or corrosion in
metal parts.
Mounting state
Check that the CF Reader/Writer is com-
pletely inserted.
There is no looseness.
The CF must be a Type II.
Phillips screw-
driver
Check that the protective cover is firmly
mounted.
The cover must be secured by screws.