manualshive.com logo in svg
background image

CIDRW SYSTEM

V640 SERIES

USER'S MANUAL

Cat. No. Z308-E1-02

AMPLIFIER UNITS

V640-HAM11-ETN

V640-HAM11-L-ETN

CIDRW HEADS

V640-HS61

V640-HS62

Содержание V640-HAM11-ETN

Страница 1: ...CIDRW SYSTEM V640 SERIES USER S MANUAL Cat No Z308 E1 02 AMPLIFIER UNITS V640 HAM11 ETN V640 HAM11 L ETN CIDRW HEADS V640 HS61 V640 HS62...

Страница 2: ...series CIDRW System Allow the CIDRW System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems Please read and understand the contents of this m...

Страница 3: ...CTION 6 SECTION 7 Table of Contents Precautions in Using the Products Product Outline Installation and Connections Wiring Preparing for Communications Reading from Writing to ID Tags Browser Interface...

Страница 4: ...NED OR RATED FOR ENSURING SAFETY OF PERSONS AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated produc...

Страница 5: ...blish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Di...

Страница 6: ...les to suppress RF interference FCC Part15 subpart B NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part15 of the FCC Rules These li...

Страница 7: ...French Par la pr sente Omron d clare que lappareil V640 HAM11 ETN V640 HAM11 L ETN est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Swedish H rm...

Страница 8: ...AM11 ETN V640 HS61 CMIIT ID 2010DJ5965 V640 HAM11 L ETN V640 HS62 Amplifier Unit CIDRW Head OMR V640 HAM11 ETN V640 HAM11 ETN V640 HS61 OMR V640 HAM11 L E V640 HAM11 L ETN V640 HS62 Amplifier Unit CID...

Страница 9: ...he information provided in all safety precautions The following signal words are used in this manual Meanings of Alert Symbols Alert Statements in this Manual Indicates a potentially hazardous situati...

Страница 10: ...please perform it after switching off this product Provide enough space around this product for ventilation Please avoid installing this product near the machinery a heater a transformer large capacit...

Страница 11: ...olarity when connecting to the power supply terminals Do not run high voltage lines and power lines though the same conduit To avoid static induced failure wear a wrist band or equivalent means to rel...

Страница 12: ...ended 0 6N m When multiple CIDRW Heads are mounted next to each other communications performance could be impaired by mutual interference Read and follow the information in this manual on mutual inter...

Страница 13: ...he product is used incorrectly data or the equipment itself could be destroyed Indicates summaries of points of particular importance relating to product performance e g points to note during operatio...

Страница 14: ...12 INTRODUCTION Precautions in using the product CIDRW System User s Manual INTRODUCTION MEMO...

Страница 15: ...Outline 13 What Is a CIDRW System 14 Features 15 System Configuration 16 Component Names and Functions 17 Flowchart for Getting Started 20 SECTION 2 Installation and Connections Wiring 23 Installatio...

Страница 16: ...6 Troubleshooting 69 Troubleshooting 70 SECTION 7 Appendix 77 Specifications and Dimensions 78 Connection Examples 82 Characteristic Data According to Conditions of Use 83 ID Tag Memory Maps 113 Regu...

Страница 17: ...ON 1 Product Outline 15 CIDRW System User s Manual SECTION 1 Product Outline What Is a CIDRW System 16 Features 17 System Configuration 18 Component Names and Functions 19 Flowchart for Getting Starte...

Страница 18: ...eviation is used throughout this manual Reading and writing information such as models process instructions lots and inspection results to and from ID Tags makes it possible to manage work instruction...

Страница 19: ...fier Unit is equipped with Ethernet The host device is connected through a LAN cable and controls the Amplifier Units using TCP IP The Amplifier Units provide a Web browser function that allows commun...

Страница 20: ...IP address of the Amplifier Unit can be either set on this DIP switch or the desired IP address can be set in ROM If pins 1 to 5 on the DIP switch are all turned OFF the IP address that is set in ROM...

Страница 21: ...mmunications with the host device or during communications with an ID Tag 5 NORM indicator green Turns ON when the communications finish with no error 6 ERROR indicator red Turns ON when an error occu...

Страница 22: ...ed on the OPERATING indicator Refer to page 34 Refer to V640 HAM11 ETN and V640 HAM11 L ETN Amplifier Units for information on the OPERATING indicator for communi cations results Refer to page 19 Alwa...

Страница 23: ...me Function 1 Antenna Used to communicate with ID Tags 2 Antenna center This is the center of the communications area 3 Connector Connect to an Amplifier Unit No Name Function 1 Antenna Used to commun...

Страница 24: ...9 Refer to page 34 Refer to page 35 Refer to page 36 Installation Connection and Wiring Setting the Communications Conditions for Amplifier Units Test for Communications with the Host Device ID Tag CI...

Страница 25: ...SECTION 1 Product Outline Refer to page 38 Refer to page 72 List of Error Messages Refer to page 72 Amplifier Unit Indicators Refer to page 73 Operation Check Flowchart Communications Test with Actual...

Страница 26: ...24 SECTION 1 Flowchart for Getting Started CIDRW System User s Manual SECTION 1 Product Outline MEMO...

Страница 27: ...2 Installation and Connections Wiring 25 CIDRW System User s Manual SECTION 2 Installation and Connections Wiring Installation 26 Amplifier Unit 26 CIDRW Head 27 Connections and Wiring 29 Amplifier U...

Страница 28: ...Installation and Connections Wiring Installation Amplifier Unit Use spring washers and flat washers with the four M4 screws when mounting the Amplifier Unit Tighten the M4 screws with a torque not exc...

Страница 29: ...communications Data Reading and Writing The communications distances for reading and writing are not the same the distance is shorter for writing Therefore when data is to be both read and written tak...

Страница 30: ...communications restricting the communications area The noise levels in the vicinity of the CIDRW Head can be determined with the environmental NOISE MEASUREMENT command applies only when SECS is not u...

Страница 31: ...nnector and insert the cable connector Hold the fixed part of the connector while making this insertion 2 After inserting the connector fully home turn the fixed part clockwise to lock it Disconnectin...

Страница 32: ...le or straight LAN cable The shape and dimensions of plugs and jacks for Ethernet connectors are specified in ISO IEC 8877 1992 JIS X 5110 1996 To prevent faulty connections for connectors the jack on...

Страница 33: ...onnector pins Power Supply Use a power supply that satisfies the following conditions The maximum power consumption of the Amplifier Unit is 150 mA at 24 VDC V640 HAM11 V3 400 mA at 24 VDC V640 HAM11...

Страница 34: ...32 SECTION 2 Connections and Wiring CIDRW System User s Manual SECTION 2 Installation and Connections Wiring MEMO...

Страница 35: ...SECTION 3 Preparing for Communications 33 CIDRW System User s Manual SECTION 3 Preparing for Communications Setting the Communications Conditions for Amplifier Units 34 Communications Test 35...

Страница 36: ...to make the setting effective Disabled OFF IP address Always OFF Not used in this CIDRW system Test Mode Always OFF Not used in this CIDRW system IP Address IP address DIP switch 1 2 3 4 5 Setting in...

Страница 37: ...o confirm that the host device and Amplifier Unit are connected correctly Refer to Host Communications Specifications Refer to page 81 A test is preformed for the Amplifier Unit using the data 1234567...

Страница 38: ...the ID Tag will be as follows ID Tag contents Page 1 12h 34h 56h 78h 90h 12h 34h 56h Page 2 Page 3 11h 22h 33h 44h 55h 66h 77h 88h Page 4 Response code Page 1 Page 3 CR 0 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4...

Страница 39: ...Reading from Writing to ID Tags Command Response Format 38 READ 39 WRITE 40 SAME WRITE 42 BYTE WRITE 43 TEST 44 NAK 45 GET PARAMETER 45 GET LAST COMMAND 50 GET COMMUNICATIONS HISTORY 50 CLEAR COMMUNIC...

Страница 40: ...s for an ID Tag can be specified p 42 BYTE WRITE 0400 When this command is received the system communicates with the ID Tag and writes data to the area specified by a first address and number of bytes...

Страница 41: ...the CIDRW Head or the CIDRW Head is unable to detect the ID Tag due to environmental factors e g noise 7B Outside write area error A write operation was not completed normally because the ID Tag was i...

Страница 42: ...h 56h Page 2 Page 3 11h 22h 33h 44h 55h 66h 77h 88h Page 4 Response code Page 1 Page 3 CR 0 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 0Dh Command 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0...

Страница 43: ...ages that are to be read to 1 and setting the other bits to 0 then converting the result to a hexadecimal character string Write data The data to be written to the specified pages is specified in asce...

Страница 44: ...e other bits to 0 then converting the result to a hexadecimal character string Write data Specify the write data Response code CR 0 0 0Dh Response code CR 0 0 0Dh Command Command code Page designation...

Страница 45: ...en normal 00 is returned Example Writing Two Bytes of Data to Address 05h of the Amplifier Unit The ID Tag status on normal completion is as shown below Command code First address Write data CR Data 1...

Страница 46: ...0 and the received test data are returned Example Performing a Test for the Amplifier Unit Using the Data 12345678 Command code Test data CR Data 1 Data n 1 0 0Dh Parameter Description Parameter Descr...

Страница 47: ...normal and received parameter value are returned The contents and length of the parameter value depend on the parameter type that is specified for the command Command code CR 1 2 0Dh Command code Para...

Страница 48: ...ode 00 normal and firmware version are returned as a 4 digit decimal number The above response is for a firmware version of 1 00 Example 3 Getting the MAC Address of Amplifier Unit Command code Parame...

Страница 49: ...lifier Unit The response code 00 normal and IP address on the DIP switch decimal four octets of 3 digits each are returned The above response is for when the IP address on the DIP switch is 192 168 1...

Страница 50: ...is 192 168 1 200 Example 8 Checking the Subnet Mask in ROM The response code 00 normal and subnet mask decimal four octets of 3 digits each are returned The above response is for when the subnet mask...

Страница 51: ...is normal 01 and is error 00 Example 10 Getting the Antenna Connection Status of Amplifier Unit The response code 00 normal and Antenna connection status are returned Antenna connectionstatus will be...

Страница 52: ...s total successful communications and total number of failed communications This command returns the history of communications from when the power was turned ON Four hexa decimal digits each are retur...

Страница 53: ...noise in the vicinity of the CIDRW Head are measured and the noise level is expressed numerically in the range 00 to 99 The response code when normal 00 and the noise level 00 to 99 are returned Influ...

Страница 54: ...the following characters can be used in passwords 0 to 9 a to z and A to Z If any other characters are used error 14 will occur If the password is not between 1 and 16 characters long error 14 will oc...

Страница 55: ...lifier Unit before a response is received from the Amplifier Unit for this command Doing so may damage the Amplifier Unit The values are enabled when the Amplifier Unit is restarted Command code First...

Страница 56: ...54 SECTION 4 Command Response Format CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags MEMO...

Страница 57: ...SECTION 5 Browser Interface 55 CIDRW System User s Manual SECTION 5 Browser Interface Browser Operation Windows 56 Window Configuration 57...

Страница 58: ...om ja Java and all trademarks and logos related to Java are trademarks or registered trademarks of Sun Microsystems Inc in the USA and other countries Before starting the Browser Window make sure that...

Страница 59: ...57 CIDRW System User s Manual SECTION 5 Window Configuration SECTION 5 Browser Interface Window Configuration IP address of Amplifier Unit Language Buttons Menu Buttons Main Display...

Страница 60: ...assword is set in the Amplifier Unit the Password Entry Window will be displayed before the Browser Window is displayed Enter the password and click the OK Button in this window If the pass word is co...

Страница 61: ...User s Manual SECTION 5 Window Configuration SECTION 5 Browser Interface If the password is not correct the following window will be displayed Click the Retry Button The Password Entry Window will be...

Страница 62: ...Status Window displays the model number firmware version MAC address and other information on the Amplifier Unit so that you can check it Click the Refresh Button at the top of the window to update th...

Страница 63: ...gs ROM If the Amplifier Unit is set to use the IP address that is set in ROM this item is displayed in blue and the IP address and subnet mask of the Amplifier Unit are displayed If the Amplifier Unit...

Страница 64: ...restarted If the Save Button is clicked when the password box is empty the Web password will be cleared In this state the browser interface can be used without entering the Web password The following...

Страница 65: ...Manual SECTION 5 Window Configuration SECTION 5 Browser Interface Command Window The Command Window can be used to communicate with ID Tags The Command Window has two tab pages CID R W and V640 Comman...

Страница 66: ...D R W Tab Page allows you to read or write ID Tag data by specifying the offset length and maximum bytes of CID If writing is executed you must also specify the write data CID Read Button CID Write Bu...

Страница 67: ...visible ASCII characters are detected for a CID read they will be converted to aster isks Item Description Comments Offset Specify the CID offset between 0 and 15 bytes Length Specify the CID length...

Страница 68: ...V640 Command Tab Page The V640 Command Tab Page allows you to read and write data according to the command format of the Amplifier Unit OK NG Display Area Page Designation Area Send Button Page Write...

Страница 69: ...Write Designation Area Select Read or Write in the Page Write Designation Area OK NG Display Area The command execution results will be displayed as OK or NG in the OK NG Display Area If NG is display...

Страница 70: ...ace Page Designation Area Select the check boxes to specify the pages to be read or written Write Data Designation Area When writing data specify the data to write to the ID Tag as a hexadecimal strin...

Страница 71: ...ment Window The Noise Measurement Window allows you to continuously send the NOISE MEASUREMENT com mand to the Amplifier Unit and display the results in realtime The horizontal axis gives the time and...

Страница 72: ...70 SECTION 5 Window Configuration CIDRW System User s Manual SECTION 5 Browser Interface MEMO...

Страница 73: ...SECTION 6 Troubleshooting 71 CIDRW System User s Manual SECTION 6 Troubleshooting Troubleshooting 72...

Страница 74: ...written to an ID Tag 72 No Tag error Either there is no ID Tag in front of the CIDRW Head or the CIDRW Head is unable to detect the ID Tag due to environmental factors e g noise 7B Outside write area...

Страница 75: ...ly Indicators RUN COMM NORM ERROR Response Code for the Response Type Response code Function Normal 00 The command was received normally Error occurrence Test command transmission RUN indicator OFF No...

Страница 76: ...ifier Unit may be damaged Influence of background noise change installation position Amplifier Unit power supply If the error cannot be resolved after checking the Amplifier Unit may be damaged RUN CO...

Страница 77: ...ation Operation Check Flowchart Refer to page 73 Indicators RUN COMM NORM ERROR Response Code for the Response Type Response code Function Normal 00 The ID Tag was processed normally Error occurrence...

Страница 78: ...e of the response after transmission of the command After taking appropriate corrective action send the write command again and check again RUN COMM NORM ERROR Main check points If RUN is OFF the stat...

Страница 79: ...ction Distance to another CIDRW Head Influence of background noise Change installation position Please check the Antenna Connection Status by using GET PARAMETER command Refer to page 49 page 20 If th...

Страница 80: ...78 SECTION 6 Troubleshooting CIDRW System User s Manual SECTION 6 Troubleshooting MEMO...

Страница 81: ...ser s Manual SECTION 7 Appendix Specifications and Dimensions 80 Connection Examples 84 Characteristic Data According to Conditions of Use 85 ID Tag Memory Maps 115 Regular Inspection 116 ASCII Code T...

Страница 82: ...0 VDC M Dielectric strength Leak current not to exceed 5 mA on application of 1000 VAC 50 60 Hz for 1 minute between both power supply terminals and the frame ground terminal Vibration resistance Freq...

Страница 83: ...ng a connection Communications with the ID Tag will be aborted if the Ethernet cable is disconnected or the connection is broken while the Amplifier Unit is communicating with an ID Tag Item Descripti...

Страница 84: ...d 5 mA on application of 1000 VAC 50 60 Hz for 1 minute between all terminals and the case Vibration resistance Frequency 10 to 150 Hz double amplitude 0 20 mm acceleration 15 m s2 for 8 minutes 10 ti...

Страница 85: ...VAC 50 60 Hz for 1 minute between all terminals and the case Vibration resistance Frequency 10 to 150 Hz double amplitude 0 20 mm acceleration 15 m s2 for 8 minutes 10 times each in X Y and Z directio...

Страница 86: ...1 ETN LAN cable CIDRW Head V640 HS61 Amplifier Unit V640 HAM11 ETN LAN cable The Amplifier Unit controls the CIDRW Head The CIDRW Head is the antenna It reads and writes carrier IDs and performs other...

Страница 87: ...ts of temperature and so on and should be thoroughly con firmed on installation The direction of the ID Tags will affect communications performance Check the direction of the coils in the ID Tags befo...

Страница 88: ...20 30 40 50 60 70 80 90 100 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 Communications Area READ Distance in Z direction mm Measurement point Distance in Y direction mm 0 10 20 30 40 50 60 70 80...

Страница 89: ...30 40 50 60 70 80 90 100 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 0 Communications Area READ Distance in Y direction mm Distance in X direction mm Measurement point 10 20 30 40 50 60 70 80 9...

Страница 90: ...10 20 20 30 30 40 40 50 50 60 70 80 60 70 80 0 10 20 30 40 50 60 70 80 90 100 Communications Area READ Distance in Y direction mm Distance in Z direction mm Measurement point 0 10 20 30 40 50 60 70 80...

Страница 91: ...20 30 40 50 60 70 80 90 100 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 Communications Area READ Distance in Y direction mm Distance in X direction mm Measurement point 0 10 20 30 40 50 60 70 80...

Страница 92: ...10 20 20 30 30 40 40 50 50 60 70 80 60 70 80 0 10 20 30 40 50 60 70 80 90 100 Communications Area READ Distance in Y direction mm Distance in Z direction mm Measurement point 0 10 20 30 40 50 60 70 80...

Страница 93: ...TRP WR2B READ WRITE 0 30 60 90 120 150 180 200 0 50 100 150 200 200 150 100 50 Distance in Y direction mm Distance in X direction mm Measurement point Communications Area READ 0 30 60 90 120 150 180...

Страница 94: ...RI TRP WR2B READ WRITE 0 30 60 90 120 150 180 200 0 50 100 150 200 150 100 50 Distance in Y direction mm Distance in Z direction mm Measurement point Communications Area READ 0 30 60 90 120 150 180 20...

Страница 95: ...RI TRP WR2B READ WRITE 0 30 60 90 120 150 180 200 0 50 100 150 200 150 100 50 Distance in Y direction mm Distance in X direction mm Measurement point Communications Area READ 0 30 60 90 120 150 180 20...

Страница 96: ...RI TRP WR2B READ WRITE 0 30 60 90 120 150 180 200 150 100 50 0 50 100 150 200 Distance in Y direction mm Distance in Z direction mm Measurement point Communications Area READ 0 30 60 90 120 150 180 0...

Страница 97: ...RI TRP WR2B READ WRITE 0 30 60 90 120 150 180 200 0 200 50 100 150 150 100 50 Distance in Y direction mm Distance in X direction mm Measurement point Communications Area READ 0 30 60 90 120 150 180 20...

Страница 98: ...RI TRP WR2B READ WRITE 0 30 60 90 120 150 180 200 0 200 50 100 150 150 100 50 Distance in Y direction mm Distance in Z direction mm Measurement point Communications Area READ 0 30 60 90 120 150 180 2...

Страница 99: ...nications Area READ Distance in Y direction mm Distance in X direction mm Measurement point 0 20 0 20 40 60 80 100 120 140 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 Communications A...

Страница 100: ...Area READ Distance in Z direction mm Measurement point Distance in Y direction mm 0 20 0 20 40 60 80 100 120 140 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 Communications Area READ...

Страница 101: ...s Area READ Distance in Y direction mm Distance in X direction mm Measurement point 0 20 0 20 40 60 80 100 120 140 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 Communications Area READ...

Страница 102: ...s Area READ Distance in Y direction mm Distance in Z direction mm Measurement point 0 20 0 20 40 60 80 100 120 140 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 Communications Area READ...

Страница 103: ...s Area READ Distance in Y direction mm Distance in X direction mm Measurement point 0 20 0 20 40 60 80 100 120 140 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 Communications Area READ...

Страница 104: ...s Area READ Distance in Y direction mm Distance in Z direction mm Measurement point 0 20 0 20 40 60 80 100 120 140 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 Communications Area READ...

Страница 105: ...pendix 103 Coaxial Mounting RI TRP WR2B READ WRITE Distance in Y direction mm Distance in X direction mm Measurement point Communications Area READ 0 0 50 30 50 60 90 120 150 180 100 100 150 150 200 2...

Страница 106: ...RI TRP WR2B READ WRITE Distance in Y direction mm Distance in Z direction mm Measurement point Communications Area READ 0 0 50 30 50 60 90 120 150 180 100 100 150 150 200 200 Distance in Y direction...

Страница 107: ...RI TRP WR2B READ WRITE Distance in Y direction mm Distance in X direction mm Measurement point Communications Area READ 0 0 50 30 50 60 90 120 150 180 100 100 150 150 200 200 Distance in Y direction...

Страница 108: ...RI TRP WR2B READ WRITE Distance in Y direction mm Distance in Z direction mm Measurement point Communications Area READ 0 0 50 30 50 60 90 120 150 180 100 100 150 150 200 200 Distance in Y direction...

Страница 109: ...RI TRP WR2B READ WRITE Distance in Y direction mm Distance in X direction mm Measurement point Communications Area READ 0 0 50 30 50 60 90 120 150 180 100 100 150 150 200 200 Distance in Y direction...

Страница 110: ...RI TRP WR2B READ WRITE Distance in Y direction mm Distance in Z direction mm Measurement point Communications Area READ 0 0 50 30 50 60 90 120 150 180 100 100 150 150 200 200 Distance in Y direction...

Страница 111: ...Systems are installed close to each other mutual interference between the Heads can result in mal functions If this is a problem install the CIDRW Heads separated at least by the distances shown in t...

Страница 112: ...metal body However ensure the distances indicated below between the CIDRW Head and the metal body If you do not ensure these distances the communications distance will be substantially shortened Meta...

Страница 113: ...of pages 8 277 2 TAT calculation formula units ms TAT command and response transmission time communications time The command and response transmission time differs depending on the network environment...

Страница 114: ...600 bps is shown below The communications time and TAT however may increase substantially according to the conditions of use 0 500 1000 1500 2000 2500 3000 3500 Read Number of pages processed Communic...

Страница 115: ...lease confirm beforehand there is a difference in comparision with V640 HAM11 V2 and V640 HAM12 in communication time 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8...

Страница 116: ...f the CIDRW Head power supply noise and atmospheric noise to ensure that the noise level does not exceed 10 NOISE MEASUREMENT command applies only when SECS is not used Refer to page 51 V640 HAM11 ETN...

Страница 117: ...07h 2 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 3 10h 11h 12h 13h 14h 15h 16h 17h 4 18h 19h 1Ah 1Bh 1Ch 1Dh 1Eh 1Fh 5 20h 21h 27h 6 28h 29h 2Fh 7 30h 31h 37h 8 9 10 11 12 13 14 68h 69h 6Fh 15 70h 71h 77h 16 78...

Страница 118: ...e To be within the specified range Maximum and minimum ther mometer Hygrometer Ambient humidity Vibration and shock Check that no vibration or shock is trans mitted from any machines Dust Check that t...

Страница 119: ...0 NUL TC7 DLE SP 0 P p Undefined Undefined Undefined 0001 1 TC1 SOH DC1 1 A Q a q 0010 2 TC2 STX DC2 2 B R b r 0011 3 TC3 ETX DC3 3 C S c s 0100 4 TC4 EOT DC4 4 D T d t 0101 5 TC5 NEQ TC8 NAK 5 E U e...

Страница 120: ...es and solid bodies with a diameter of 2 5 mm or greater 4 Protected against access by wires and solid bodies with a diameter of 1 mm or greater 5 Entry of volumes of dust that would cause difficultie...

Страница 121: ...or 1 minute per square meter of outer cas ing with a minimum total exposure of 3 minutes 6 Protection against powerful jets of water Water does not enter the product when a powerful jet of water is di...

Страница 122: ...owing table outlines the changes made to the manual during each revision Page numbers refer to the previous version Revision code Date Revised content 01 September 2010 Original production 02 January...

Страница 123: ...U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Contact www ia omron com Tokyo JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 30...

Отзывы: