manualshive.com logo in svg
background image

i

V550-A20 Operation Manual

V550-A20 Bar Code Reader

Operation Manual

Cat. No. Q01BAZ2

Содержание V550-A20

Страница 1: ...i V550 A20 Operation Manual V550 A20 Bar Code Reader Operation Manual Cat No Q01BAZ2...

Страница 2: ...mmable Controller and is not used as an abbreviation for anything else Visual Aids The following headings appear in the left column of the manual to help you locate different types of information Note...

Страница 3: ...External Device Introduction 3 1 Connecting Your V550 A20 To Other External Devices 3 2 Connecting Your V550 A20 to a PC 3 5 Connecting Your V550 A20 to a Terminal 3 7 Supplying Power to the V550 A20...

Страница 4: ...bes unpacking mounting and basic setup of the V550 A20 Section 3 Explains how to connect the V550 A20 to external devices and how to supply power to the bar code reader Section 4 Provides information...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...ing terms are discussed that may be helpful while mounting your V550 A20 Finally this Section describes how to mount each piece of equipment within your V550 A20 system and how to set up your V550 A20...

Страница 16: ...UL Class 2 Mounting Hardware five different mounting options are offered All of the options depend on the type of application they are to be used in Each is described below with its part number Mounti...

Страница 17: ...serial port on the back of a personal computer when setting up the V550 A20 software The PC setup program is called BCSETUP Refer to your BCSETUP manual for details about pro gramming the V550 A20 Thi...

Страница 18: ...the bar code are perpendicular to the direction of travel Regardless of the direction of travel the scan line must be perpendicular to the bars Direction of Travel Bar Codes In Ladder left And Picket...

Страница 19: ...he V550 A20 can be to the bar code and still read the bar code passing through its scan line The Far Distance is the farthest distance at which the V550 A20 can read a bar code The Depth of Field is t...

Страница 20: ...are designed to hold the V550 A20 in a position so the scan line is parallel to the mounting surface Each clip has an oblong slot designed for a 6 mounting screw The mounting screws are to be located...

Страница 21: ...he mounting surface Step 2 The plate has one fixed retaining clip one 6 32 stud and one 6 nut that holds the adjustable clip Place the V550 A20 in position so the slot in the side of the housing is en...

Страница 22: ...igned for 6 mounting screws on either side of the V550 A20 Mounting screws need to be located 2 25 inches apart To mount the V550 A20 Step 1 Place the bracket around the V550 A20 so the backing of the...

Страница 23: ...are designed for 6 mounting screws on either side of the V550 A20 Mounting screws need to be located 3 00 inches apart To mount the V550 A20 Step 1 Place the bracket around the V550 A20 so the backing...

Страница 24: ...is parallel to the mounting surface Four 6 32 Pem nuts are provided on the bottom of the bracket To mount the V550 A20 The top edges on both sides of the cradle are bent at a 90 degree angle This resu...

Страница 25: ...0 as explained in Section Three Step 3 If you need to make any programming changes to your V550 A20 connect your V550 A20 to a PC or terminal as described in Section Three of this manual and refer to...

Страница 26: ...12 V550 A20 Operation Manual Section 2 12 What to Do After Receiving the V550 A20...

Страница 27: ...PC and Terminal This chapter also explains how to supply power to your V550 A20 You must make these connections before you can begin setting up or using your V550 A20 Introduction 3 1 Connecting to ot...

Страница 28: ...ws all the pin connections for V550 A20 when using serial communications If you need to create your own cables to wire your V550 A20 to another device use these drawings as a guide It is very importan...

Страница 29: ...e Length 50 Feet V550 A20 GND RXD TXD HOST NOTE All connectors are shown from the soldering side 15 6 1 2 3 1 15 11 TXD RXD GND 5VDC GND 5 CTS CTS RTS RS 232 With RTS CTS Handshaking Use the following...

Страница 30: ...Multidrop serial communication SD RD NOTE RS485 allows for communication across the same lines Termination resistors can be placed inside the connector strain relief The termination resistor value is...

Страница 31: ...n Part Name Part Number Programming Kit V559 A25C Programming Kit V550 A20 Programming Kit 110V AC part V559 A25C To connect your V550 A20 to most PCs using the Programming Kit Step 1 Plug in the 15 p...

Страница 32: ...nections from your PC to your V550 A20 with connector and cable specifications Specifications 15 pin connector Assmann part A HDF15LL T or equivalent 9 pin connector CINCH part DEM 9S or equivalent Ca...

Страница 33: ...may be different Before you begin making your cable check your Terminal documentation to make sure these pin connections are accurate Specifications 15 pin connector Assmann part A HDF15LL T or equiva...

Страница 34: ...ector is grounded This pro vides chassis ground to the unit case and is necessary for proper operation Using Omron s Power Supply For Power You can use the Omron S82S 0305 power supply to supply power...

Страница 35: ...ntioned in the beginning of this section to ensure proper operation The drawings below show alternate ways of wiring power into the V550 A20 V550 A20 15 6 1 1 15 GND 5VDC V550 A20 15 6 1 1 15 GND 5VDC...

Страница 36: ...and 13 The drawing below shows two of the most common ways to wire a triggering device directly to your V550 A20 Note Connector is shown from the soldering side J1 J1 DEM 9P 1 11 1 11 Trigger GND 74X...

Страница 37: ...mes of the two outputs directly reflect their purpose The NVC NO MATCH output changes its electrical state dependent on receiving a no read or a no match while in verifier mode The GO MATCH output tim...

Страница 38: ...oad V550 A20 15 6 1 1 GND OUT 1 5 Load Output Connections The table below defines some basic terminology The drawing below shows the schematic of the outputs circuitry Model 20 15 6 1 4 5 2 TTL Output...

Страница 39: ...h 5 of CQM1 and set 1000 on DM6645 to match the communication condition with BCR refer to the CQM1 Programming Manual for the detailed way to change the condition Setting of Start Code Stop Code Set 1...

Страница 40: ...rammable controller TXD 48 DM0101 0000 0001 Send 1 byte of DM0101 Set to 5300 S send command to stop reading Confirmation of Operation After programming set RUN mode and set the trigger switch ON to e...

Страница 41: ...ondition Set OFF the dip switch 5 of C200HS or C200H Alpha and set 1000 on DM6645 to match the communication condition with BCR refer to the Reference Manual for the detailed way to change the conditi...

Страница 42: ...rising pulse Trigger switch OFF DIFFERENTIATE DOWN on falling pulse DIFD 14 00102 Send 1 byte of DM0100 Set to 4700 G send command to start reading TXD 48 DM0100 0000 0001 BSET 71 0000 DM0200 DM0220 R...

Страница 43: ...Rs respond to the polls There is no response if they are not polled by the master Message Formats V550 A20 Communication Setting 1 CPU C200H 2 Bar code reader V550 A20 3 Power supply unit S82S 0305 5V...

Страница 44: ...The above connection is shown using the C200H Alpha PLC with protocol macro function Contact OMRON for the latest V550 A20 Protocol macro FF hex Guard character Ignored by receiver STX 02hex Start of...

Страница 45: ...A20 hardware was specifically designed for the tough industrial environment The unit does not need anything more than some basic cleaning and a checkup every once and awhile This chapter provides you...

Страница 46: ...d to be shipped back for repair Refer to your Omron distributor for more information To clean the V550 A20 Step 1 Slightly dampen a lint free cloth with a solution made of mild detergent and water Ste...

Страница 47: ...ct your Omron distributor Is there dust on the V550 A20 Are all the connections tight Are any cables damaged The V550 A20 is ready for operation Use the steps on page 5 2 to clean the V550 A20 Refer t...

Страница 48: ...length Solution Enable code type or correct code length Refer to section 5 6 of the BCSETUP Programming Manual Problem V550 A20 has poor read rate Cause V550 A20 window is dirty label is not within re...

Страница 49: ...n 5 1 Appendices Section 5 Appendices Appendix A ASCII Communications 5 2 Appendix B ASCII Chart 5 11 Appendix C V550 A20 Read Distance Charts 5 12 Appendix D V550 A20 and Accessories Dimensions 5 15...

Страница 50: ...es using the Master Slave method The Master Slave system works as follows The master device usually a decoder logic or computer originates poll messages The poll message is a message from the master t...

Страница 51: ...code for a single hexadecimal digit Some examples are 35h is the code for a five 42h is the code for a B which equals 11 base 10 the hexadecimal number 5A would be encoded by the two HEX digits 35h an...

Страница 52: ...nit identification number of the unit to which the message is directed if the message is coming from the master This field indicates the unit identification number of the unit transmit ting the messag...

Страница 53: ...ng all the characters in the ID TYPE SEQ and data fields then converting the hex number into two ascii digits This mathematical process checks to make sure that the message is valid CR 0Dh Carriage re...

Страница 54: ...a gap of more than one half a character time between characters Most transmissions will take place under interrupt so this should not be a problem however it means that serial port interrupts may not...

Страница 55: ...traints on the master The master may have any amount of time between messages or between characters within its message Error Recovery Error The slave does not understand a poll message Recovery None T...

Страница 56: ...e number re ceived there is no requirement that the sequence number must be the next number expected although in some systems the master will keep track of out of sequence errors since they would indi...

Страница 57: ...t STX unit id 2 char 0 1 lrc 2 char CR Example STX 0 1 0 1 0 0 CR HEX 02h 30h 31h 30h 31h 30h 30h 0Dh 2 SLAVE answers the poll with the data in the following format STX unit id 0 2 seq 1 char data lrc...

Страница 58: ...other additional lines in the cable ACK NAK This is a software protocol When a unit receives a message it indi cates whether it has received that message correctly If all informa tion is received the...

Страница 59: ......

Страница 60: ...0 8 mm 2 00 in 76 2 mm 3 00 in 101 6 mm 4 00 in 127 mm 5 00 in 152 4 mm 6 00 in 0 00 mm 0 00 in 177 8 mm 7 00 in 203 2 mm 8 00 in 228 6 mm 9 00 in 254 mm 10 0 in 279 4 mm 11 0 in 304 8 mm 12 00 in Rea...

Страница 61: ...25 4 mm 1 00 in 50 8 mm 2 00 in 76 2 mm 3 00 in 101 6 mm 4 00 in 127 mm 5 00 in 152 4 mm 6 00 in 0 00 mm 0 00 in 177 8 mm 7 00 in 203 2 mm 8 00 in 228 6 mm 9 00 in 254 mm 10 0 in 279 4 mm 11 0 in 304...

Страница 62: ...38 mm 20 0 mil 51 mm 2 0 4 0 51 102 mm 2 0 4 25 51 108 mm 2 0 4 5 51 114 mm 2 0 5 0 51 127 mm 2 0 6 0 51 152 mm 3 2 81 mm 3 4 86 mm 3 6 91 mm 4 0 102 mm 4 8 122 mm Scan Rate 300 Scans Per Seconds 76 2...

Страница 63: ...2 40 Six M3 5 156 X 281 Slot 9 7 38 7 1 28 18 3 72 5 3 21 2 3 09 3 0 12 Appendix D V559 A32 A M BCR to OMRON PLC RS 232 Port Cable 156 X 281 Slot 4PL 7 4 29 62 2 2 45 8 6 34 PEM FH 632 6 3 3 13 62 2 2...

Страница 64: ...ing Bracket 156 X 281 2 PL 1 9 75 9 7 38 6 4 2 5 5 7 2 25 55 8 2 2 53 6 2 1 69 9 2 75 26 9 1 06 15 7 62 15 2 60 39 4 1 55 156 X 281 2 PL 19 05 75 9 65 38 76 2 3 00 6 35 25 8 89 3 50 31 75 1 25 25 4 1...

Страница 65: ...emote interlock connector N A N A N A N A R R Key control N A N A N A N A R R Emission indicator N A N A R R R R Beam attenuator N A N A N A R R1 R1 Note In the chart above R Require N A Not applicabl...

Страница 66: ...18 V550 A20 Operation Manual Section 5 18 Appendices...

Страница 67: ...s of data referred to as characters Bar Code Character A single group of bars and spaces that represent an individual number letter or other symbol Bar Code Density The number of characters that can b...

Страница 68: ...ry stock The print head moves across the label printing one dot at a time to complete one line The print head then begins printing the next line Other dot matrix printers use a stationary print head T...

Страница 69: ...are paired together using bars to represent the first character and spaces to represent the second I O Input Output The keyboard and a printer are examples of I O devices I O activity is different fro...

Страница 70: ...and could not be decoded No Read When the scanner is unable to decode a bar code as it passes through the scan zone Non Read The absence of data at the scanner output after an attempted scan due to n...

Страница 71: ...the label are good Another problem for a picket fence orientation is the placement of the label If the placement is off enough a single scan line will not read all the bar codes presented to the scan...

Страница 72: ...nears its memory capacity the receiving device sends an ASCII X OFF signal to the transmitting device telling it to stop sending data When the memory buffer has enough space to handle more data the X...

Страница 73: ...re two types of thermal printers One uses a method similar to the dot matrix printer where an array of heated dots move along the paper and form the character or bar code The other method uses a heate...

Страница 74: ...8 V550 A20 Operation Manual Glossary 8...

Страница 75: ...racket 2 10 Facts to know Before 2 4 Ladder Bracket 2 8 Picket Fence Bracket 2 9 Plate 2 7 N Near Distance 2 5 No read indication 1 8 O Omron Power Supply 3 8 Operating Parameters 1 3 Optical Throw 2...

Страница 76: ...2 V550 A20 Operation Manual INDEX 2...

Отзывы: