Chapter 1
1-7
Communications Methods
Moving to Communications Parameters
M
M
U
U
U
U
U
U
U
D
D
D
D
D
D
D
U
D
Frequency reference
RUN Mode Screen Display
Initial Settings
Mode Screen Display
Communications
unit number
Communications
baud rate
Communications
data length
Communications
stop bits
Communications
parity
45.
2
p01
p14
p15
p16
p17
p18
p19
p20
p21
Note: Communications
parameters
Power ON
When the power is turned ON, the data display and indicators (setting
and monitoring indicators) will all light, and then the present frequency
reference be displayed on the data display.
When the Mode Key is pressed for 1 s or longer, the mode will change
from RUN mode to initial settings mode, and
p01
will appear on the
data display.
Use the Increment and Decrement Keys to move to parameters P15
to P19. (The parameter that is to be set will be displayed.)
(See
note.)