IX
■
Installation and Storage Environment
• Do not store, install, or operate the product in any of the following locations.
• Locations subject to direct sunlight.
• Locations subject to temperatures outside the range specified in the specifications.
• Locations subject to humidity outside the range specified in the specifications.
• Locations subject to condensation resulting from severe changes in temperature.
• Locations subject to corrosive or flammable gases.
• Locations subject to exposure to combustibles.
• Locations subject to dust (especially iron dust) or salts.
• Locations subject to exposure to water, oil, or chemicals.
• Locations subject to shock or vibration.
■
Transporting, Installation, and Wiring
• Always use the original shipping box when transporting the Inverter.
• Do not apply excessive shock to the Inverter or drop the Inverter. The Inverter may malfunction
or may be damaged.
• Do not connect an AC power supply voltage to the U, V, and W output terminals. Doing so will
damage the Inverter.
• Do not connect any load other than a three-phase inductive motor to the U, V, and W output
terminals.
• Do not connect an AC power supply voltage to the control I/O terminals. Doing so will damage
the Inverter.
• Use 600-V polyvinyl chloride (PVC) cable with a wire size of 0.75 to 2 mm
2
to wire the main
circuit terminals. Also, tighten the terminal screws on the terminal block to a torque of 0.8 to
1.0 N·m.
• Take appropriate and sufficient shielding countermeasures when installing systems in the fol-
lowing locations. Not doing so may result in malfunction or equipment damage.
• Locations subject to static electricity or other forms of noise.
• Locations subject to strong electromagnetic fields and magnetic fields.
• Locations close to power lines.
■
Operation and Maintenance
• This Inverter can be set to operate from low speed to high speed. Operate the Inverter only
after sufficiently confirming the allowable range for the motor installation being used.
• Take measures to assure safety before performing maintenance or inspection, or replacing
components.
Precautions for Safe Use
Содержание SYSDRIVE 3G3JV
Страница 1: ...Cat No I548 E1 01 COMMUNICATIONS MANUAL 3G3JE Compact Simplified Inverters...
Страница 14: ...Chapter 1 Communications Methods 1 1 Overview of Communications Methods...
Страница 38: ...Chapter 3 Communications Data 3 1 Variable Area Setting Range List 3 2 Status...
Страница 42: ...Chapter 4 Appendix 4 1 ASCII List...