![Omron STC-MBS2041POE Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/omron/stc-mbs2041poe/stc-mbs2041poe_product-specifications-and-users-manual_742907050.webp)
No.18S065-03
50/71
STC-MBS2041POE / STC-MCS2041POE
Product Specifications and User’s Guide
10.12 Image Flip
The vertical flip image can be selected by “Reverse Y”.
* Horizontal flip image function is NOT available.
* The first image after change vertical flip parameter when selecting “Rolling” at “Exposure Shutter Type”,
is brightness gradation image (bottom of image is brighter). This phenomenon is also occurred when selecting
“Global Reset” at “Exposure Shutter Type”, and “Reverse Y”.
GenICam Parameters
ReverseY
IBoolean Type
Vertical flip image ON / OFF selection
Selection: “False” (Vertical flip is Off), “True” (Vertical flip is On)
Default: “False” (Vertical flip is Off)
10.13 LUT Control
The output signal assigned table for input signal.
GenICam Parameters
LUT Selector
IEnumeration Type
Control LUT selection (Luminance is only selectable)
Default: Luminance
LUT Enabled
IBoolean Type
LUT ON / OFF selection
LUT Index
IInteger Type
Index for LUT
Range: 0 to 4,095
LUT Value
IInteger Type
The output value for input value that specifies by index
Range: 0 to 4,095
LUT Index
0
4095
LU
T
Va
lu
e
4095
e.g. LUT usage (low brightness level enhancement)