![Omron STC-MBS2041POE Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/omron/stc-mbs2041poe/stc-mbs2041poe_product-specifications-and-users-manual_742907026.webp)
No.18S065-03
26/71
STC-MBS2041POE / STC-MCS2041POE
Product Specifications and User’s Guide
6.2.6.4 Measured External Trigger Signal Delay through Open Collector GPIO Port (Line 2)
Measurement circuit
Positive polarity trigger signal
Negative polarity trigger signal
Pull-up voltage
Tdelay
Minimum active
pulse duration
Pull-up voltage
Tdelay
Minimum active
pulse duration
+3.3 V
3.9 μseconds
6 μseconds
+3.3 V
0.6 μseconds
6 μseconds
+12 V
3.8 μseconds
3 μseconds
+12 V
0.8 μseconds
3 μseconds
+24 V
2.2 μseconds
2 μseconds
+24 V
0.8 μseconds
2 μseconds
Note. Please use this measured delay as reference. The delay time may fluctuate depending on transistor variation,
pull-up voltage and pull-up resister.