No.13S076-08
16/62
STC-MBCM200U3V / STC-MCCM200U3V / STC-MBCM200U3V-NIR
STC-MBCM401U3V / STC-MCCM401U3V / STC-MBCM401U3V-NIR Product Specifications and Use’s Guide
Precautions
(*1) The sensitivity is measuring the luminance when white level achieved 100 % in below conditions.
(*2) The multiple ROI regions cannot set on the same horizontal line.
(*3)
The binning and decimation function cannot use simultaneously.
(*4) Do not input the trigger signal that faster than maximum frame rate frequency.
The ReadOut is interrupted, If the exposure is finished during ReadOut from sensor by the input trigger signal.
(*5) The camera operates as USB3.0 standard even the camera connecting to a USB 2.0 port. Please careful
about the power consumption of the camera when the camera connecting to USB2.0 port.
The guideline to perform the full frame rate with full resolution of camera
The data transfer speed on the USB bus is depending on the performance of USB host controller.
The data transfer speed on the USB bus is very important to obtain full frame rate with full resolution. (167 fps @
2M, 89 fps @ 4M)
Renesas / Fresco Logic host controller improved the data transfer speed drastically in the second generation.
However, the transferring speed of Intel chipset is 10 to 20% faster than these host controllers.
When using USB3.0 interface PCI Express board, please insert it to the PCI Express Gen2.0 (5.0[GT/s]) slot. If
non-PCI Express Gen2.0 (5.0[GT/s]) is used, data transfer speed could decrease by about 50%.
If the frame rate is slow due to the performance of USB host controller, the frame rate of camera should adjust
based on the performance of USB host controller. This may resolve to increase the frame rate.
PC resources may have consumed during the image processing (color interpolation, image display, etc.) with huge
image data from camera.
Camera Setting
Environment
Parameter
Setting
Parameter
Setting
Gain Up
0 dB
Light Source
Light Box (White)
AGC
Off
Color temperature 5,100K
White Balance
Optimum
Lens
Electrical Shutter 1/30 seconds
F on Lens
F5.6
Black Level
Optimum
Target Luminance IM-600 (Topcon)
Gamma
Factory Setting