Explicit Messages
Appendix A
Slice Bus
Error Out-
put Setting
Write/
Read
Sets the Slice Bus error
output value for each
output.
0: Hold last state
1: Low limit
2: High limit
3: Zero count
Operation example:
Turnback Cable discon-
nect.
Write:
10 hex
Read:
0E hex
90 hex
01 to 40
hex
*1
6C hex
*2
82 hex
*3
1 byte
1 byte
Communi-
cations
Error Out-
put Setting
Write/
Read
Sets the communica-
tions error output value
for each output.
0: Hold last state
1: Low limit
2: High limit
3: Zero count
Operation example:
communications error in
Communications Unit.
Write:
10 hex
Read:
0E hex
90 hex
01 to 40
hex
*1
6D hex
*2
83 hex
*3
1 byte
1 byte
Function
Setting
Write/
Read
Sets the function.
Scaling: 0;
Cumulative counter: 1
Write:
10 hex
Read:
0E hex
90 hex
01 to 40
hex
*1
6F hex
*2
85 hex
*3
1 byte
1 byte
Scaling
Type Set-
ting
Write/
Read
Default scaling: 0:
User scaling: 1
Write:
10 hex
Read:
0E hex
90 hex
01 to 40
hex
*1
70 hex
*2
86 hex
*3
1 byte
Scaling
Point 1 Set-
ting
Write/
Read
Sets a conversion value
as the 0% value for user
scaling.
Write:
10 hex
Read:
0E hex
90 hex
01 to 40
hex
*1
71 hex
*2
87 hex
*3
2 bytes
(
−
28000 to
28000)
2 bytes
(
−
28000 to
28000)
Scaling
Point 2 Set-
ting
Write/
Read
Sets a conversion value
as the 100% value for
user scaling.
Write:
10 hex
Read:
0E hex
90 hex
01 to 40
hex
*1
72 hex
*2
88 hex
*3
2 bytes
(
−
28000 to
28000)
2 bytes
(
−
28000 to
28000)
Offset
Compensa-
tion after
Scaling
Write/
Read
Sets an offset to com-
pensate for scaling
error.
Write:
10 hex
Read:
0E hex
90 hex
01 to 40
hex
*1
73 hex
*2
89 hex
*3
2 bytes
(
−
28000 to
28000)
2 bytes
(
−
28000 to
28000)
Cumulated
Value Read
Read/
Reset
Reads the cumulated
analog output value.
Read:
0E hex
Reset:
35 hex
90 hex
01 to 40
hex
*1
77 hex
*2
8D hex
*3
4 bytes
(
−
214748364.8
to
214748364.8)
Cumulative
Counter
Flag Read
Read Reads the cumulative
count status in the
Cumulative Counter
Flag in the area for
Generic Status Flags.
0: Counter overflow
1: Counter underflow
7: Set value overflow
Read:
0E hex
90 hex
01 to 40
hex
*1
78 hex
*2
8E hex
*3
1 byte
Explicit
message
Read
/write
Function Command
Response
Service
code
Class
ID
Instance
ID
Attribute
ID
Data Size
Содержание SmartSlice GRT1-Series
Страница 1: ...Slice I O Units Cat No W455 E1 06 SmartSlice GRT1 Series OPERATION MANUAL ...
Страница 2: ...SmartSlice GRT1 Series Slice I O Units Operation Manual Revised November 2007 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 13: ...xiv ...
Страница 21: ...xxii EC Directives 6 ...
Страница 63: ...42 Connecting Turnback Cables Section 3 3 ...
Страница 109: ...88 Digital I O Units Section 4 6 ...
Страница 251: ...230 Maintenance Information Window Section 7 3 Maintenance Information Window ...
Страница 293: ...272 GRT1 CP1 L Positioning Unit Section 7 5 ...
Страница 301: ...280 GRT1 END End Unit Section 8 5 Dimensions 11 9 11 9 55 7 1 5 19 5 83 5 2 9 2 9 OMRON ...
Страница 323: ...302 Troubleshooting by Unit Section 9 5 ...
Страница 351: ...330 Explicit Messages Appendix A ...
Страница 355: ...334 Power Consumption and Weight Tables Appendix C ...
Страница 357: ...336 I O Current Consumption Table Appendix D ...
Страница 365: ...344 Revision History ...