No.16S058-01
21/49
STC-HD133 Series (STC-HD133DV / STC-HD133SDI) /
STC-HD93 Series (STC-HD93DV / STC-HD93SDI) Users guide
b. COMM
1) Port Setting
Set up the communication port.
a) Port
Please select the COM port that connects to the communication port of the camera.
Please check the COM port number at the device manager.
b) Baud rate
The baud rate of the PC selects automatically to match to the baud rate of the camera.
The baud rate of the camera is 38,400bps.
c) Change camera baud rate
Select the operation if the baud rate of the camera is not 38,400bps
ShowDialog
: The dialog is displayed.
ChangeSilentry : The baud rate of the camera changes to 38,400bps automatically.
DontChange
: The baud rate of the camera does not change.
d) Debug Mode
The details of the communication data can review by “Debug View” software when “Debug
Mode” is selected.
2) Read All
The current camera settings receive from the camera.
3) DSP -> EEPROM
The current DSP preset settings save to the EEPROM.
4) EEPROM -> DSP
The current DSP preset settings load from the EEPROM.
5) uCOM -> EEPROM
The current uCOM settings save to the EEPROM.
6) EEPROM -> uCOM
The uCOM settings load from the EEPROM.