S8VS
16
Nomenclature
*
The terminal arrangement is the same for models with screwless
terminal blocks and standard models.
*1.
The fuse is located on the (L) side. For a DC input, connect the
positive voltage to the L terminal.
*2.
This is the protective earth terminal specified in the safety
standards. Always ground this terminal.
*3.
The output voltage cannot be adjusted for the
S8VS-09024
@@@
S.
*4.
S8VS-
@@@
24A
@@
/B
@@
/BE
@
only.
*5.
S8VS-
@@@
24A
@@
/B
@@
only (except the S8VS-06024
@
).
*6.
Both sinking and sourcing outputs are available.
*7.
S8VS-
@@@
24A
@@
only (excluding S8VS-06024A).
*8.
S8VS-
@@@
24B
@@
only (excluding S8VS-06024B).
60-W Models
Standard Model
S8VS-06024
Models with Indication Monitor
S8VS-06024
@
Note:
The S8VS-06024A is shown above.
90-W/120-W Models
Standard Models
S8VS-09024/S8VS-0924S/
S8VS-12024
Models with Indication Monitor
S8VS-09024
@@@
/
S8VS-09024
@@@
S/S8VS-12024
@@@
Note:
The S8VS-12024A is shown above.
180-W Models
Standard Model
S8VS-18024
Models with Indication Monitor
S8VS-18024
@@@
Note:
The S8VS-18024A is shown above.
240-W Models
Standard Model
S8VS-24024
Models with Indication Monitor
S8VS-24024
@@@
Note:
The S8VS-24024A is shown above.
1
3
2
4
5
1
3
2
4
8
7
6
5
3
1
2
4
5
3
1
13
12
11
2
4
5
8
9
7
6
10
3
1
2
3
4
5
1
2
3
4
5
11 13
6
10
12
7
8
9
4
5
3
1
2
13
11
4
5
8
9
7
12
6
10
3
1
2
No.
Name
Function
1
Input terminals
(L), (N)
Connect the input lines to these
terminals.
*
1
2
Protective Earth
terminal (PE)
Connect the ground line to this
terminal.
*
2
3
DC Output terminals
(
−
V), (+V)
Connect the load lines to these
terminals.
4
Output indicator
(DC ON: Green)
Lights while a direct current (DC)
output is ON.
5
Output voltage
adjuster (V.ADJ)
Use to adjust the voltage.
*
3
6
Main display (Red)
*
4
Indicates the measurement or set
value.
7
Operation
indicator
(Orange)
*
4
V
Lights up when the output voltage is
indicated. Blinks during setup of
undervoltage alarm value.
A
Lights up during indication of output
current.
Apk
Lights up during indication of peak
hold current.
Yrs
Lights up during indication of
maintenance forecast monitor.
Blinks during setup of maintenance
forecast monitor setting. (S8VS-
@@@
24A
@@
)
kh
Lights up during indication of total
run time monitor. Blinks during setup
of total run time monitor. (S8VS-
@@@
24B
@@
)
8
Mode Key
*
4
Use the Mode Key to change the
indicated parameter or reset the
peak hold current value.
9
Up Key
*
5
Use the Up Key to change to the
setting mode or to increase the set
value.
10
Down Key
*
5
Use the Down Key to change to the
setting mode or to decrease the set
value.
11
Alarm
outputs
*
5,
*
6
Undervoltage
output
terminal (DC
Low)
Output when a drop is detected in
the output voltage (voltage drop =
transistor OFF).
12
Maintenance
Forecast
output
terminal (Yrs)
*
7
Output when the set value for
maintenance is reached (transistor
OFF).
Total run time
output
terminal (kh)
*
8
Output when the set value for total
run time is reached (transistor OFF).
13
Common
terminal
Common terminal for terminals 11
and 12.