6 Basic Parameter Settings
6 - 70
High-function General-purpose Inverter RX2 Series User’s Manual
If the acceleration or deceleration cancel [LAC] function is selected as the input terminal function
selection and the signal is turned ON, the acceleration or deceleration time becomes ignored and the
output frequency is made instantaneously to follow the set frequency.
Precautions for Correct Use
• As the use of the acceleration or deceleration cancellation function makes the output follow
the command, a large amount of increase/decrease in the frequency demanded by the com-
mand may cause a trip.
• [LAC] function is valid for any frequency command such as one from parameter set-up, one
from the communication, and so on.
6-7-6
Following Frequency Command
Item
Parameters
Data
Description
Input terminal function
selection
[CA-01] to
[CA-11]
071
Acceleration or deceleration cancellation func-
tion [LAC] is selected.
Canceling the acceleration or deceleration and
making the output follow the command
[LAC]
ON
ON
Follow the acceleration or
deceleration time
Time
Output frequency
Analog frequency command
Following the
command
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......