35
5.
Please adjust criteria and click next
•
If you choose the manual setting of settling time, gain will be increased gradually
until achieving the specified settling time. The positioning window, specify the
position deviation to determine that the positioning is completed. If it detects a
vibration above the vibration detection level during tuning, an adjustment failure will
occur.
•
If you select the best effort mode, gain will be increased gradually until the system
does not exceed the vibration detection level.
6.
Please click start, be careful the motor will move
Criteria achieved
Click next
Содержание R88D-1SNx-ECT Series
Страница 1: ...Servo System 1S series Startup Guide R88M 1L 1M AC Servomotors R88D 1SN ECT AC Servo Drives I823 E1 01...
Страница 17: ...17 2 Approach the drive from top to down 3 Tight the upper part 4 Tight the down part...
Страница 38: ...38 6 Add the Emergency stop button 7 Add the Reset button 8 Edit I O Map variables...
Страница 58: ...58 11 Results Wizard step 5 Save to EEPROM Finish...