3.2. System configuration with NJ and NX safety controller
■ Ethercat node address configuration
1.
Please configure the Ethercat node address of the drive to 1.
Note: You can configure the node address depending on your application
2.
In case of using NX safety, please configure the node address of the NX coupler to
2.
Note: You can configure the node address depending on your application
3.
Please connect EtherCAT cables to devices
CN10 Ethercat IN: Ethercat cable from NJ EtherCAT Master
CN11 Ethercat OUT: Ethercat cable to NX coupler unit
Additional Information
For further details about safety controller, please refer to the NX-series safety control
units user manual Z930