manualshive.com logo in svg
background image

M-48

AC Axial-flow Fans

 

Common Information

Warranty and Application Considerations

Read and Understand this Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you 
have any questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or 
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER 
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET 
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, 
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, 
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE 
MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of 
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will 
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR 
SYSTEM.

Disclaimers

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a 
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application 
requirements. Actual performance is subject to the OMRON 

Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with 
your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. X068-E1-03

Содержание R87FT -

Страница 1: ...re not provided 1 2 3 4 5 6 7 1 120 120 9 92 92 8 80 80 3 25 5 38 6 40 8 7 55 R87 1 Basic series R87F Plastic blade R87T Metal blade 2 Rated voltage A1 100 VAC A3 115 VAC A4 200 VAC A6 230 VAC 3 Frame...

Страница 2: ...M 16 AC Axial flow Fans R87F R87T...

Страница 3: ...R87F A4A15LP 200 VAC Yes Yes R87F A6A15LP 230 VAC Yes Yes Yes R87F A1A13HP 100 VAC High Yes Yes Yes Refer to page 23 R87F A3A13HP 115 VAC Yes Yes Yes Yes R87F A4A13HP 200 VAC Yes Yes Yes R87F A6A13HP...

Страница 4: ...5H 100 VAC Yes Yes Refer to page 33 R87T A3A05H 115 VAC Yes Yes R87T A4A05H 200 VAC Yes Yes R87T A6A05H 230 VAC Yes Yes R87T A1A15HP 100 VAC High Yes Yes Tab terminals Refer to page 35 R87T A3A15HP 11...

Страница 5: ...gree of Protection International Protection Degree of protection against international of foreign objects in fan motor First digit of IP Code Protection against International of Solids Second digit of...

Страница 6: ...n mat black baked coating Blades PBT glass black UL94V 0 Insulation resis tance 100 M min at 500 VDC between all power supply connections and uncharged metal parts Bearings Ball bearings Insulation wi...

Страница 7: ...F A4A15MP R87F A6A15MP 100 115 200 230 85 to 110 rated voltage 50 60 0 220 0 185 0 100 0 090 0 195 0 165 0 090 0 082 15 14 2350 2550 2 3 2 6 61 8 63 7 42 44 R87F A1A15LP R87F A3A15LP R87F A4A15LP R87F...

Страница 8: ...pressure Ps Pa Static pressure Ps Pa Flow rate Q m3 min Flow rate Q m3 min Flow rate Q m3 min Four 4 3 dia Protective tube Black 100 V White 200 V Direction of rotation Side with label front Directio...

Страница 9: ...0 145 0 125 0 072 0 063 14 12 2500 2850 2 0 2 3 52 0 52 0 40 44 R87F A1A13LP R87F A3A13LP R87F A4A13LP R87F A6A13LP 100 115 200 230 85 to 110 rated voltage 50 60 0 110 0 096 0 058 0 051 0 096 0 084 0...

Страница 10: ...Cut outs Options R87F A A13HP R87F A A13LP Static pressure Ps Pa Static pressure Ps Pa Flow rate Q m3 min Flow rate Q m3 min 9 M4 screw 0 7 pitch 9 2 8 Screw hole for grounding Terminal shape Faston...

Страница 11: ...110 0 098 0 052 0 048 10 9 2600 3050 1 0 1 2 46 1 62 8 34 38 R87F A1A93LP R87F A3A93LP R87F A4A93LP R87F A6A93LP 100 115 200 230 85 to 110 rated voltage 50 60 0 084 0 075 0 043 0 035 0 073 0 065 0 038...

Страница 12: ...ressure Ps Pa Flow rate Q m3 min Flow rate Q m3 min Three 4 3 dia Direction of flow Protective tube Black 100 V White 200 V Direction of rotation 9 M4 screw 0 7 pitch 9 2 8 Screw hole for grounding Te...

Страница 13: ...11 0 097 0 055 0 049 9 8 2800 3250 0 66 0 76 41 2 54 9 38 43 R87F A1A85LP R87F A3A85LP R87F A4A85LP R87F A6A85LP 100 115 200 230 85 to 110 rated voltage 50 60 0 064 0 055 0 032 0 028 0 057 0 050 0 029...

Страница 14: ...Static pressure Ps Pa Static pressure Ps Pa Flow rate Q m3 min Flow rate Q m3 min Four 4 3 dia Direction of flow Protective tube Black 100 V White 200 V Direction of rotation 6 M4 screw 0 7 pitch 9 2...

Страница 15: ...0 038 0 080 0 071 0 036 0 034 7 6 2600 3000 0 57 0 67 39 2 53 0 34 38 R87F A1A83L R87F A3A83L R87F A4A83L R87F A6A83L 100 115 200 230 85 to 110 rat ed voltage 50 60 0 070 0 059 0 032 0 029 0 061 0 05...

Страница 16: ...Options R87F A A83H R87F A A83L Static pressure Ps Pa Static pressure Ps Pa Flow rate Q m3 min Flow rate Q m3 min Four 4 3 dia Side with label front Direction of flow Protective tube Black 100 V Gray...

Страница 17: ...A3A07H R87T A4A07H R87T A6A07H 100 115 200 230 85 to 110 rat ed voltage 50 60 0 660 0 450 0 330 0 210 0 560 0 400 0 280 0 190 37 34 2750 3050 5 0 5 8 111 7 127 5 55 59 Ambient operating temperature 2...

Страница 18: ...tic Pressure on page 45 Dimensions Panel Cut outs Options R87T A A07H Static pressure Ps Pa Flow rate Q m3 min Direction of rotation Direction of flow Two 4 3 dia Protective tube Black 100 V White 200...

Страница 19: ...3A05H R87T A4A05H R87T A6A05H 100 115 200 230 85 to 110 rat ed voltage 50 60 0 540 0 430 0 240 0 220 0 470 0 380 0 210 0 200 35 33 2600 2950 5 2 5 8 98 1 88 3 54 56 Ambient operating temperature 20 to...

Страница 20: ...ge 45 Dimensions Panel Cut outs Options R87T A A05H Static pressure Ps Pa Flow rate Q m3 min Direction of rotation Direction of flow Two 4 3 dia Protective tube Black 100 V White 200 V Side with label...

Страница 21: ...110 0 100 0 210 0 170 0 100 0 091 16 15 2700 3050 2 5 2 9 68 6 68 6 43 47 R87T A1A15MP R87T A3A15MP R87T A4A15MP R87T A6A15MP 100 115 200 230 85 to 110 rated voltage 50 60 0 220 0 180 0 102 0 096 0 20...

Страница 22: ...rate Q m3 min R87T A A15MP Static pressure Ps Pa Flow rate Q m3 min Four 4 3 dia Protective tube Black 100 V White 200 V Direction of rotation Side with label front Direction of flow 9 M4 screw 0 7 p...

Страница 23: ...85H R87T A4A85H R87T A6A85H 100 115 200 230 85 to 110 rat ed voltage 50 60 0 170 0 140 0 081 0 069 0 150 0 120 0 069 0 060 11 10 2700 3150 0 73 0 87 33 3 46 1 35 40 Ambient operating temperature 20 to...

Страница 24: ...Panel Cut outs Options R87T A A85H Static pressure Ps Pa Flow rate Q m3 min Direction of rotation Direction of flow Four 4 3 dia Protective tube Black 100 V White 200 V Side with label front Screw hol...

Страница 25: ...Ambient storage temperature 40 to 85 C no icing Ambient humidity 25 to 85 RH Insulation class UL class A 105 C Insulation resistance 100 M min at 500 VDC between all power supply connections and uncha...

Страница 26: ...M 40 AC Axial flow Fans with Lead Wires 80 x 80 x t25 mm R87T A A83 Options Name Model Page number Finger Guard R87F FG80 Refer to page 41 Filter R87F FL80 Refer to page 42...

Страница 27: ...CSA Note UL File No E175022 Cord length Model number 1 m R87F PC 2 m R87F PC 20 R87F PC Thermoplastic flat twin core cord black UL SPT 1 AWG 18 41 0 16 Connectable to Faston 110 terminals or equivalen...

Страница 28: ...hod 1 Attach the guard to the Fan using the mounting bolts There are no mount ing bolts provided with the Plastic Fil ter 2 With the media held between the retainer and the guard hook the retainer to...

Страница 29: ...l flow Fans Common Information M 43 Others Application Examples 1 Control Panels 2 Computer 3 Measurement Devices 4 Medical Equipment 5 Soldering Fume Extractor 6 Automatic Vending Machines and Displa...

Страница 30: ...is sub jected to shock e g dropped Ensure that the Fan is not subjected to shock otherwise the service life and performance characteristics of the Fan will be adversely affected Wiring Prevent short c...

Страница 31: ...tual characteristics may differ from the values represented in the graphs A simple explanation of the flow rate static pressure characteristics and the methods of measuring them is given below Maximum...

Страница 32: ...C Normally between 8 to 10 C W amount of heat generated kW 4 Estimate the system impedance from the air flow through the Unit or from previous data P KQn P Pressure drop Pa K Unit constant n Coefficie...

Страница 33: ...zero Pa at the flow measurement unit Maximum Static Pressure Ps max Pa The pressure difference inside and outside the Unit when the flow rate is adjusted to zero 0 m3 min at the flow measurement unit...

Страница 34: ...REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s...

Отзывы: