4-3 Motherboard RAS Functions
4-3-1 Standard PC RAS Data
4-7
4
RAS Functions
4-3 Motherboard RAS Functions
The NSA-series Industrial PC can read standard PC RAS data (voltage,
temperature, fan rpm). It also has additional unique RAS functions, such as POST
error logging, POST error retry, and CMOS data recovery.
4-3-1 Standard PC RAS Data
The NSA-series Industrial PC can read the following standard PC RAS data.
No.
Monitored
hardware data
Description
1
CPU temperature
sensor
Temperature data read via the SMBus interface
(hardware monitor interface). (Not converted to degrees
centigrade)
2
No. of fan rotations
(See note.)
Fan rpm (2 fans) and the fan log (per fan) read via the
SMBus interface (hardware monitor interface). (Not
converted to rotations per minute)
3 Board
voltage
Voltages read via the SMBus interface (hardware monitor
interface). The following voltages can be read.
HVCC (3.3 V)
V12 (+12 V)
V5 (+5 V)
VTR (3.3 V)
V25 (+2.5 V)
Vccp
V18 (+1.8 V)
V15 (+1.5 V)
(Not converted to voltage)
4
POST error logs
BIOS startup log data (approximately 40 bytes for the 10
most recent errors) read from specified CMOS addresses
in the chipset.
Note: The NSA-series Industrial PC does not have a fan.
Note
Although the NSA-series Industrial PC will read RAS data from the super I/O chip
(SMSC LPC47M192) and the chipset (Intel Intel 6300ESB) on the
motherboard, it does not do conversions, such as converting to degrees of temperature.
Refer to respective datasheets for data processing (data conversion) details.
4-3-2 Unique RAS Functions
POST Error Log
When POST errors occur, the 4-byte POST error code, time, month, and date for
up to 32 errors are logged as individual POST error records. These records can be
read from the BIOS setup menu.
Error data can be retained indefinitely without relying on the internal battery for
backup because POST error logs are saved in the motherboard EEPROM. This
also means that error data can only be deleted from the BIOS setup menu.
Note: After 32 errors, the most recent error will overwrite the oldest error. Individual
error records cannot be deleted. If you delete one error record, they will all be
deleted.
Содержание NSA12-15-TX11B
Страница 2: ......
Страница 3: ...NSA Series Industrial PC NSA12 15 TX11B NSA12 15 TX11S NSA12 15 TX12B NSA12 15 TX12S User s Manual...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 20: ...xx...
Страница 25: ...Section 1 Overview and Specifications...
Страница 33: ...Section 2 Nomenclature...
Страница 37: ...Section 3 Installing the NSA series Industrial PC and Connecting Peripheral Devices...
Страница 59: ...Section 4 RAS Functions...
Страница 73: ...Section 5 Maintenance...
Страница 81: ...Appendix...
Страница 113: ......
Страница 114: ...Cat No V238 E1 02 Printed in Japan 0508...