7-3 Error Messages and Countermeasures
7-4
7-3 Error Messages and Countermeasures
This section describes the countermeasures for errors that are peculiar to the NS-Runtime.
For information on other error messages, refer to 5-2 Error Messages in the NS Series
Programming Manual and the Error messages and Countermeasures in the CX-Designer
Online Help.
Messages displayed on the CX-Designer.
Message Cause
Possible Countermeasure
Attempted to convert a project
for which the serial port A/B
was set to one of the following
settings to NS-Runtime.
-Host type other than SYSMAC-
PLC
-Temperature Controller
-Memory Link
-Barcode
-Modem connection
-General-purpose protocol
Convert a project for which the
serial ports are set to the
SYSMAC-PLC, or convert a
project for which the serial ports
are set to be not used.
The project for conversion does
not support xx. Cancel the
setting of xx before converting.
Attempted to convert a project
for which the host type
connected to Ethernet was not
SYSMAC-CS/CJ or SYSMAC-
CV to NS-Runtime.
Convert a project for which the
host type connected to Ethernet
is SYSMAC-CS/CJ or SYSMAC-
CV.
Attempted to convert an NS-
Runtime project with more than
50,000 records in a normal log
to an NS-series project.
Change the log so that it
contains less than 50,000
records and attempt the
conversion again.
Process was aborted because a
setting that cannot be converted
was found. For details, refer to
the Output Window.
Attempted to convert an NS-
Runtime project with macros
supported only by the NS-
Runtime to an NS-series
project.
Delete macros that can be used
only for NS-Runtime and attempt
the conversion again.
Only one document display can
be placed in a screen.
Attempted to place two or more
document display objects on
one screen.
Only one document display can
be created on each screen.
A document display cannot be
created on a sheet.
Attempted to place a document
display object on a sheet.
Create a document display
object on a base screen.
The object that cannot be
arranged on the pop-up screen
is contained.
Attempted to place a document
display objects on a pop-up
screen.
Create a document display
object on a base screen.
Some objects cannot be pasted
on the frame.
Attempted to place a document
display object on a frame
object.
Create a document display
object on a base screen.
The Document Folder Path is
not set.
Document folder path has not
specified in a Document Table
Setting Dialog Box.
Specify a path.
Specify the Save Cycle to
between 1 second and 24
hours.
Value out of range has been set
for the save cycle of the Internal
Holding Memory in the System
Setting Dialog Box.
Set a value to between one
second and 24 hours for the
save cycle.
Destination folder is not set.
On the system setting dialog
box, the save destination of
history data has not been
selected yet.
Specify a path.
Содержание NS-NSRCL Series
Страница 1: ...Cat No V093 E1 05 NS Runtime Software USER S MANUAL...
Страница 2: ......
Страница 28: ...1 4 Comparison between the NS Series and the NS Runtime 1 14...
Страница 38: ...2 6 User Interface 2 10...
Страница 56: ...3 5 Converting Projects 3 18...
Страница 84: ...4 5 Macros 4 28...
Страница 136: ...5 11 Window Size 5 52...
Страница 154: ...7 3 Error Messages and Countermeasures 7 6...
Страница 156: ......
Страница 157: ......