MK-S(X)
2
Specifications
Ratings
Operating Coil
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C with tolerances of +15%/
−
20% for AC rated current and
±
15% for DC coil resistance.
2.
Performance characteristic data are measured at a coil temperature of 23
°
C.
3.
The maximum allowable voltage is the maximum value of the allowable voltage range for the operating power supply for the relay coil.
There is no continuous allowance.
4.
The rated current is approximately 5 mA higher for Models with Built-in Operation Indicators (DC operating coils).
Item
Rated current (mA)
Coil
resistance
(
Ω
)
Must
operate
voltage (V)
Must
release
voltage (V)
Maximum
voltage
allowable (V)
Power
consumption
(VA, W)
Rated voltage (V)
50 Hz
60 Hz
Percentage of rated voltage
AC
24
110
96.3
48.4
80% max.
30% min. at
60 Hz
25% min. at
50 Hz
110%
Approx. 2.3 VA
at 60 Hz
Approx. 2.7 VA
at 50 Hz
100
26.6
23.1
760
110
24.2
21.0
932
120
22.2
19.3
1,130
200
13.3
11.6
3,160
220
12.1
10.5
3,550
230
11.5
10.0
4,250
240
11.0
9.6
4,480
DC
12
126
95
15% min.
Approx. 1.5 W
24
63.2
380
48
32.0
1,500
110
13.6
8,060
220
6.8
32,200