background image

13

3.Using the Unit

EN

3.2

Applying the Arm Cuff 

Be sure to wrap the arm cuff correctly so that you get accurate results. 
Measurements can be taken in light clothing. However, please remove 
thick clothes, such as sweaters, before taking a reading.

1.

Connect the air tube of the arm cuff and the inflation bulb to 
their respective air connectors.

2.

Put your left arm through the cuff 
loop.

Note:

If the cuff is not assembled, 
pass the end of the cuff 
furthest from the tubing 
through the metal D-ring to 
form a loop. The smooth 
cloth should be on the inside 
of the cuff loop.

HEM-4022-IM_Main_[D].book  13 ページ  2011年11月2日 水曜日 午後3時24分

Содержание M1 Compact

Страница 1: ...1 Compact Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ Instrukcja Kezelési Útmutató EN FR DE IT ES NL RU PL HU IM HEM 4022 E 04 10 2011 1664455 7D AR ...

Страница 2: ... 11 3 1 How to Sit Correctly When Taking a Measurement 11 3 2 Applying the Arm Cuff 13 3 3 Taking a Reading 15 3 4 Using the Memory Function 20 4 Quick Reference Guide 23 Care and maintenance 5 Handling Errors and Problems 24 5 1 Error Messages 24 5 2 Troubleshooting 26 6 Maintenance and Storage 28 7 Optional Parts 30 8 Technical Data 31 9 Some Useful Information about Blood Pressure 33 ...

Страница 3: ...od pressure monitor operating on the oscillometric principle It measures your blood pressure and pulse rate simply and quickly The unit also stores up to 14 measurements in memory Please read this instruction manual thoroughly before using the unit For specific information about your own blood pressure CONSULT YOUR DOCTOR Before using the unit ...

Страница 4: ...ly rinse with plenty of clean water Consult a doctor immediately Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property General Usage Do not leave the unit unattended with infants or persons who cannot express their consent Do not use the unit for any purpose other than meas...

Страница 5: ... not use new and used batteries together General Precautions Do not operate unit in a moving vehicle car airplane Do not apply strong shocks and vibrations to or drop the unit and arm cuff Do not take measurements after bathing drinking alcohol smoking exercising or eating Do not forcibly bend the arm cuff or bend the air tube excessively When removing the air tube pull on the edge of the tube at ...

Страница 6: ...rview Main unit Arm Cuff A Display B I O button Power switch C Air connector for cuff and inflation bulb D M Memory button E Battery compartment F Arm cuff Medium cuff arm circumference 22 32 cm G Air Tube B A C D E G F ...

Страница 7: ...eat symbol 1 Flashes during measurement 2 If flashing after measurement completed or when viewing results stored in the memory indicates blood pressure out of recommended range P Pulse display Q Deflation symbol R Reinflation symbol S Irregular heartbeat symbol Note If your systolic or diastolic pressure is outside the standard range above 135 85 mmHg the Heartbeat symbol will blink Please refer t...

Страница 8: ...8 1 Overview Package contents others T Storage case U Four AAA alkaline LR03 batteries Instruction manual Guarantee card Blood pressure pass U T ...

Страница 9: ... the ribbed part of the cover 3 Install or replace four AAA size batteries so that the positive and negative polarities match the polarities indicated on the battery compartment 4 Put the battery cover back in place Slide the battery cover as indicated until it clicks into place Note The measurement values continue to be stored in memory even after the batteries are replaced ...

Страница 10: ...time When the symbol remains lit the batteries are exhausted You should replace the batteries with new ones at once Remove the batteries if the unit will not be used for three months or more Dispose of batteries according to applicable local regulations Four new AAA alkaline batteries will last for approximately 1500 measurements when used to take two measurements a day Since the supplied batterie...

Страница 11: ...ohol smoking or exercising for at least 30 minutes before taking a measurement Do not move or talk during measurement Correct Posture Remove tight fitting clothing from your upper arm and any thick clothing such as a sweater Do not place the cuff over thick clothes and do not roll up your sleeve if it is too tight Sit upright with your back straight Place your arm on a table so that the cuff will ...

Страница 12: ... If the values between the two arms differ substantially please check with your physician which arm to use for your measurement Incorrect Posture These situations could lead to higher blood pressure values due to strain or the arm cuff being lower than the heart If the arm cuff is at a lower position than your heart use cushions etc to adjust the height of your arm Arched back leaning forwards Sit...

Страница 13: ...remove thick clothes such as sweaters before taking a reading 1 Connect the air tube of the arm cuff and the inflation bulb to their respective air connectors 2 Put your left arm through the cuff loop Note If the cuff is not assembled pass the end of the cuff furthest from the tubing through the metal D ring to form a loop The smooth cloth should be on the inside of the cuff loop ...

Страница 14: ... should be 1 to 2 cm above the elbow 4 When the cuff is positioned correctly close the fabric fastener FIRMLY 1 The air tube should run down the inside of your forearm and be in line with your middle finger 2 The bottom of the cuff should be approximately 1 to 2 cm above your elbow 3 Apply the cuff to your upper arm so that the coloured marker blue arrow under tube is centered on the middle of you...

Страница 15: ...eflation symbol does not disappear soon press the air release button to release any air in the arm cuff 2 Pump the inflation bulb to inflate the arm cuff 1 Inflate the cuff until it is 30 to 40 mmHg above your expected systolic blood pressure value ex If your expected blood pressure is around 140mmHg inflate the arm cuff to between 170 and 180 mmHg Inflate the cuff rapidly so that the pressure is ...

Страница 16: ...display and the heartbeat symbol flashes Remain still and do not talk during measurement Note To cancel a measurement press the I O button to turn off the unit and press the air release button to release the air in the arm cuff 4 Measurement ends When the measurement is finished the deflation symbol flashes on the display Blood pressure and pulse rate values are displayed Press the air release but...

Страница 17: ...diagnosis of measured results and treatment are dangerous Please follow the instructions of your doctor 6 Undo the fastener and remove the arm cuff 7 Press the I O button to turn the unit off Note If you forget to turn the unit off it will automatically shut itself off after five minutes Diastolic blood pressure Systolic blood pressure Pulse display Common Causes of Inaccurate Results Leaning forw...

Страница 18: ...udes an irregular heartbeat feature Irregular heartbeats can influence the results of the measurement The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated If the measurement results are affected by irregular heartbeats but the result is valid the result is shown together with the irregular heartbeat symbol If the irregular heartbeats cause...

Страница 19: ...tem that drives the heartbeat Typical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse This can be caused by heart disease aging physical predisposition stress lack of sleep fatigue etc Arrhythmia can only be diagnosed by a doctor through a special examination Whether the appearance of the irregular heartbeat symbol in the results indi...

Страница 20: ...values 1 Press the I O button to turn the power on 2 When the heartbeat symbol appears on the display press the M button The result from the most recent measurement is displayed Note If there are no measurements results stored in memory the screen to the right is displayed Important If your systolic or diastolic pressure is outside the standard range the heartbeat symbol will blink when the measur...

Страница 21: ...own to cycle rapidly through the previous results If the irregular heartbeat symbol was displayed after a measurement it will also be stored in the memory with the result of that measurement 4 Press the I O button to turn the unit off Note If you forget to turn the unit off it will automatically shut itself off after five minutes ...

Страница 22: ...appears on the display first press the M button Then while holding it down press the I O button simultaneously for about 2 3 seconds All readings will then be deleted Important Be careful not to press the I O button first If the I O button is pressed first the monitor is shut off 3 Press the I O button to turn the unit off Note If you forget to turn the unit off it will automatically shut itself o...

Страница 23: ...f will be at the same level as your heart 2 Apply the arm cuff to your upper arm The coloured marker should be centred on the inside of your arm and point down the inside of the arm so that the air tube runs down the inside of your forearm and is in line with your middle finger 3 Secure the cuff around your arm using the fabric fastener strip 4 Press the I O button to turn the unit on then pump th...

Страница 24: ...t the air tube securely Refer to section 3 2 Arm cuff not applied correctly Apply the arm cuff correctly Refer to section 3 2 Clothing is interfering with the arm cuff Remove any clothing interfering with the arm cuff Refer to section 3 2 Air is leaking from the arm cuff Replace cuff with new one Refer to Chapter 7 The arm cuff was inflated above 299 mmHg Release your hand from the air inflation b...

Страница 25: ... Contact your OMRON retail outlet or distributor Refer to Chapter 8 Pressure is too low Press the inflation bulb to inflate the arm cuff until the reinflation symbol goes out Or deflate the arm cuff and repeat measurement after checking that the heartbeat symbol has been displayed Refer to section 3 3 Error Display Cause Remedy ...

Страница 26: ...be securely connected into the main unit Make sure that the air tube is connected securely Refer to section 3 2 Air is leaking from the arm cuff Replace the arm cuff with a new one Refer to Chapter 7 Arm cuff deflates too soon The arm cuff is loose Apply the cuff correctly so that it is firmly wrapped around the arm Refer to section 3 2 Cannot measure or readings are too low or too high Has the ar...

Страница 27: ... are empty Replace the batteries with new ones Refer to section 2 1 The batteries have been inserted incorrectly Insert the batteries with the correct polarity Refer to section 2 1 Other problems Press the I O button and repeat measurement If the problem continues try replacing the batteries with new ones If this still does not solve the problem contact your OMRON retail outlet or distributor Prob...

Страница 28: ...ned with a soft dry cloth Use a soft moistened cloth and soap to clean the arm cuff Do not wash the arm cuff or immerse it in water Do not use petrol thinners or similar solvents to clean the arm cuff Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging Calibration and Service The accuracy of this blood press...

Страница 29: ... not bend the air tube excessively 3 Place the arm cuff inflation bulb and main unit in the storage case Do not store the unit in the following situations If the unit is wet Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapours Locations exposed to vibrations shocks or where it will be at an angle Locations exposed to chemicals or corrosive vapours ...

Страница 30: ... cuff please replace a cuff and a bulb together Medium Arm Cuff Arm circumference 22 32 cm Large Arm Cuff Arm circumference 32 42 cm Small Arm Cuff Arm circumference 17 22 cm Small cuff and bulb combination Arm circumference 17 22 cm Regular bulb CM 4997086 7 CL 4997065 4 CS 4997076 0 4997099 9 4997965 1 ...

Страница 31: ...he device Product Description Manual Inflation Blood Pressure Monitor Model OMRON M1 Compact HEM 4022 E Display LCD Digital Display Measurement Method Oscillometric method Measurement Range Pressure 0 mmHg to 299 mmHg Pulse 40 to 180 min Memory 14 Measurements Accuracy Pressure 3 mmHg Pulse 5 of display reading Inflation Manual by inflation bulb Deflation Automatic pressure release valve Pressure ...

Страница 32: ...erference may result in incorrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situations the EN60601 1 2 standard has been implemented This standard defines the levels of immunity to electromag...

Страница 33: ... of high blood pressure As a variety of conditions affect blood pressure a single measurement may not be sufficient for an accurate diagnosis Many factors such as physical activity anxiety or the time of day can influence your blood pressure Thus it is best to try and measure your blood pressure at the same time each day to get an accurate indication of any changes in blood pressure Blood pressure...

Страница 34: ... on the blood pressure values measured on people in a sitting position in outpatient departments of hospitals Note There is no universally accepted definition of hypotension However those having the systolic pressure below 100 mmHg are assumed as hypotensive 80 180 160 140 130 120 85 90 100 110 Diastolic blood pressure mmHg Systolic blood pressure mmHg Severe hypertension Moderate hypertension Mil...

Страница 35: ...2132 LR Hoofddorp THE NETHERLANDS www omron healthcare com Production facility OMRON DALIAN CO LTD Dalian CHINA Subsidiary OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 0DG U K OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH John Deere Str 81a 68163 Mannheim GERMANY www omron medizintechnik de OMRON SANTÉ FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Made in China...

Отзывы: