K8AK-VS

2

Ratings

Power supply 

voltage

Isolated power supply

24 VAC/DC

100 to 240 VAC

Power consumption

24 VAC/DC: 2.0 VA/1.1 W max.

100 to 240 VAC: 4.6 VA max.

Operating value setting range (SV)

10% to 100% of maximum setting range

K8AK-VS2:  1 to 10 V AC/DC

3 to 30 V AC/DC

15 to 150 V AC/DC

K8AK-VS3:  20 to 200 V AC/DC

30 to 300 V AC/DC

60 to 600 V AC/DC

Operating value

100% operation at set value

Reset value setting range (HYS.)

5% to 50% of operating value

Reset method

Manual reset/automatic reset (switchable)

Note:

Manual reset: Turn OFF power supply for 1 s or longer.

Operating time setting range (T)

0.1 to 30 s

Power ON lock time (LOCK)

1 s or 5 s (Switched using DIP switch.)

Indicators

Power (PWR): Green, Relay output (RY): Yellow, Alarm outputs (ALM): Red

Input impedance

Refer to 

Input Range

 on previous page.

Output relays

One SPDT relay (NO/NC switched using DIP switch.)

Output relay ratings

Rated load

Resistive load

5 A at 250 VAC

5 A at 30 VDC

Maximum contact voltage: 250 VAC or 30 VDC

Max. switching current: 5 A

Maximum switching capacity: 1,250 VA, 150 W

Mechanical life: 10 million operations min.

Electrical life: 5 A at 250 VAC or 30 VDC: 50,000 operations

3 A at 250 VAC or 30 VDC: 100,000 operations

Ambient operating temperature

20 to 60°C (with no condensation or icing)

Storage temperature

25 to 65°C (with no condensation or icing)

Ambient operating humidity

25% to 85% (with no condensation)

Storage humidity

25% to 85% (with no condensation)

Altitude

2,000 m max.

Terminal screw tightening torque

0.49 N·m

Terminal wiring method

Recommended wire

Solid wire: 2.5 mm

2

Twisted wires: AWG16, AWG18

Note: 1.

Ferrules with insulating sleeves must be used with twisted wires.

2.

Two wires can be twisted together.

Recommended ferrules

Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact

Al 1-8RD (for AWG18) manufactured by Phoenix Contact

Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact

Case color

N1.5

Case material

PC and ABS

Weight

Approx. 150 g

Mounting

Mounts to DIN Track.

Dimensions

22.5 

×

 90 

×

 100 mm 

 (W

×

H

×

D)

Содержание K8AK-VS

Страница 1: ...r to page 30 for commonly asked questions For the most recent information on models that have been certified for safety standards refer to your OMRON website Setting range Control power supply voltage...

Страница 2: ...tive load 5 A at 250 VAC 5 A at 30 VDC Maximum contact voltage 250 VAC or 30 VDC Max switching current 5 A Maximum switching capacity 1 250 VA 150 W Mechanical life 10 million operations min Electrica...

Страница 3: ...t 10564 CSA CAN CSA C22 2 No 14 CCC GB14048 5 Insulation resistance 20 M min Between external terminals and case Between power supply terminals and input terminals Between power supply terminals and o...

Страница 4: ...nerated during the instable period when the power is first turned on There is no relay output during timer operation Note There is no polarity when a DC current input is used T1 T Set value Input Powe...

Страница 5: ...dicator Terminal block See notes 1 and 2 Terminal block See notes 1 and 2 Item Meaning Power indicator PWR Green Lit when power is being supplied Relay status indicator RY Yellow Lit when relay is ope...

Страница 6: ...ng method relay drive method and operating mode are set using the DIP switch located on the bottom of the Unit Model Setting range Wiring connection K8AK VS2 1 to 10 V AC DC V1 COM 3 to 30 V AC DC V2...

Страница 7: ...the input have reached the same level Use this as a guide to set the hysteresis Example Maximum Setting of 600 VAC VDC Voltage Set Value SV of 50 and Overvoltage Operation Operation will be at 300 V a...

Страница 8: ...hod as for overvoltage Example Overvoltage Operating Mode and an Operating Time of 5 s Note K8AK VS output relays are normally operative Connection Diagram How to Measure the Operating Time Overvoltag...

Страница 9: ...s 2 Use and store the product in a location where the ambient temperature and humidity are within the specified ranges If applicable provide forced cooling 3 Mount the product in the correct direction...

Страница 10: ...will be large if the K8AK AS K8AK AW K8AK VS or K8AK VW is used for thyristor or inverter control The K8AK PH K8AK PA K8AK PM K8AK PW or K8DS PH cannot be used on the secondary side of an inverter To...

Страница 11: ...nt or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information 14 Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SP...

Страница 12: ...rasil 55 11 2101 6300 www omron com br OMRON ARGENTINA SALES OFFICE Cono Sur 54 11 4783 5300 OMRON CHILE SALES OFFICE Santiago 56 9 9917 3920 OTHER OMRON LATIN AMERICA SALES 54 11 4783 5300 OMRON INDU...

Отзывы: