93
Counting Value Reset Prohibit
•
Prohibits the counting value resetting of the K3NR when its operating mode is
set to “F7” (pulse counting).
•
This function does not prohibit the counting value resetting of the K3NR with
external signal input.
Setting
Default
kpon
: Key protect ON
kpoff
: Key protect OFF
kpoff
Refer to
5-3 External Input Signals
.
Follow the steps described below to set key protect ON.
Set Value LED Display Model
Basic Model
1, 2, 3...
1. Press the Mode Key for more than one second while the
prot
protect menu
is displayed. The
all
all key protect setting will appear.
Set Value LED Display Model
Basic Model
2. Press the Mode Key to display
reset
Counting Value Reset Prohibit setting.
Set Value LED Display Model
Basic Model
3. Press the Shift Key to display
kpoff
for changing. The PROG indicator will
flash.
Set Value LED Display Model
Basic Model
reset
FUNCTION
SETTING
MODELS
SETTING
EXAMPLE
Protect Mode
Section 4-3
Содержание K3NR
Страница 1: ...Cat No N093 E1 1A Frequency Rate Meter K3NR ...
Страница 2: ...K3NR Frequency Rate Meter Operation Manual Revised February 2001 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 148: ...Cat No N093 E1 1A K3NR Frequency Rate Meter OPERATION MANUAL ...