background image

6

Frequency inverters

JX

Compact & Complete

• V/f controlled inverter
• Side by side mounting
• Built-in EMC filter
• Built-in RS-485 Modbus
• Overload detection function (150% during 60s)
• PID
• Micro-surge voltage suppression
• Automatic energy saving
• Emergency shut-off
• Second motor setting
• Auto carrier-frequency reduction
• PTC thermistor input
• Cooling fan switch control
• PC configuration tool: CX-Drive
• CE, UL, cUL, RoHS

Ratings

• 200 V Class single-phase 0.2 to 2.2 kW
• 200 V Class three-phase 0.2 to 7.5 kW
• 400 V Class three-phase 0.4 to 7.5 kW 

 

System configuration

Choke

LCD 2 lines 
Remote Operator

Remote Operator 
Extansion Cable

* Only needed for 3 phase 200V or to comply C1 on 3 phase 400V models

Output Reactor

RJ45 - USB Cable

CX-Drive 
CX-One

*

MCCB

JX

Filter

AC Reactor

Motor

Ground

Power 
Supply

DC Reactor

Содержание JX - 2

Страница 1: ...Compact and complete JX INVERTER Cost and eco friendly Communications built in Quality reliability you can depend on...

Страница 2: ...nput Cooling fan switch control RoHS Easy network integration The RS485 Modbus is built into the RJ45 port in the inverter front making it very easy to add inverters into the network without any extra...

Страница 3: ...y is supplied to the motor This hardware based solution is more reliable than other CPU dependent solutions Convenient and efficient The parameter settings of two different motors can be stored allowi...

Страница 4: ...cy reduction PTC thermistor input Cooling fan switch control PC configuration tool CX Drive CE UL cUL RoHS Ratings 200 V Class single phase 0 2 to 2 2 kW 200 V Class three phase 0 2 to 7 5 kW 400 V Cl...

Страница 5: ...phase 20 to 40 for 1 phase Approx 20 to 40 Approx 20 Cooling method Self cooling Forced air cooling Three phase JX A4004 A4007 A4015 A4022 A4040 A4055 A4075 Motor kW1 1 Based on a standard 3 Phase sta...

Страница 6: ...n V f characteristic selection upper lower limit 16 step speeds starting frequency adjustment jogging operation carrier frequency adjustment PID control frequency jump analog gain bias adjustment S sh...

Страница 7: ...55 2 2 2 2 A2022 2 2 4 3 7 A2037 2 5 5 A2055 2 164 235 180 250 167 5 1 6 77 5 4 2 7 5 A2075 2 Three phase 400 V 0 4 A4004 2 98 176 110 189 130 5 2 6 28 1 5 0 75 A4007 2 157 5 6 55 2 3 1 5 A4015 2 2 4...

Страница 8: ...101 66 5 7 5 2 1 22 AX RC27000030 DE 105 1 60 AX RC14000047 DE AX RC10100069 DE 116 1 95 AX RC06400116 DE 108 135 133 120 82 6 5 9 5 9 5 3 70 AX RC04410167 DE 120 152 136 135 94 7 5 20 AX RC03350219...

Страница 9: ...move the short circuit bar between 1 and P 2 when a DC reactor is connected P N Regenerative braking unit connection terminal Connect optional regenerative braking units If a braking torque is require...

Страница 10: ...i function Input selection 5 Factory setting Multi step speed reference 1 L Multi function Input selection common Analog input signal H Frequency reference power supply 10 VDC 10 mA max O Voltage freq...

Страница 11: ...RC03510093 DE 9 3 3 51 1 5 AX RC14000047 DE 4 7 14 0 2 2 AX RC02510138 DE 13 8 2 51 2 2 AX RC10100069 DE 6 9 10 1 3 7 AX RC01600223 DE 22 3 1 60 4 0 AX RC06400116 DE 11 6 6 40 5 5 AX RC01110309 DE 30...

Страница 12: ...JX A2007 E 1 5 7 1 JX A2015 E 2 2 10 JX A2022 E 3 7 15 9 JX A2037 E 5 5 24 JX A2055 E 7 5 32 JX A2075 E Three phase 400 V 0 4 1 5 JX A4004 EF 0 75 2 5 JX A4007 EF 1 5 3 8 JX A4015 EF 2 2 5 5 JX A4022...

Страница 13: ...DE JX A4022 AX RC10100069 DE JX A2037 AX RC01600223 DE JX A4040 AX RC06400116 DE JX A2055 AX RC01110309 DE JX A4055 AX RC04410167 DE JX A2075 AX RC00840437 DE JX A4075 AX RC03350219 DE Model Diameter...

Страница 14: ...mron com tr United Kingdom Tel 44 0 870 752 08 61 www industrial omron co uk More Omron representatives www industrial omron eu Although we strive for perfection Omron Europe BV and or its subsidiary...