background image

W

W

W

W

A

A

R

R

R

R

R

A

A

A

A

N

N

N

N

T

T

Y

Y

Y

Y

Y

Y

Y

E

E

E

E

A

A

A

R

R

R

R

R

S

S

S

S

Sensor?

3

5

4

5

3

4

6

6

No additional devices required

Even advanced functionality such as 
PID control is standard with the JX 
inverter making it a convenient 
solution for applications such as 
pumps & fans where pressure, flow 
and other processes need 
controlling.

Automatic energy saving

The Inverter always adopts the 
optimum energy-saving setting for 
cost savings in such applications as 
fans and pumps. The inverter can 
reduce energy consumption by 
61% compared with standard 
mechanical systems.

Reliability with environmental responsibility

Omron is renowned for the reliability of its products. 
Moreover, Omron’s policy is to offer environmentally 
safe products free from any banned substances.

Reliable emergency shutdown

The IGBT’s output is directly 
switched off from the external input, 
assuring no energy is supplied to the 
motor. This hardware-based solution 
is more reliable than other CPU 
dependent solutions.

Convenient and efficient

The parameter settings of two 
different motors can be stored, 
allowing the inverter to drive 
different motors with a unique 
inverter. The two motors are never 
working at the same time.

Silent operation

Depending on the inverter 
temperature, switching off the fan 
creates a noise-free atmosphere and 
prolongs the life time of the product.

Maximise motor life

Advanced PWM control is used to
suppress micro-surge voltages that
sometimes cause malfunction in 
400 V motors. The motor is thus 
protected and its life is prolonged.

for your application

Everything on-board

Heating section

Motor

Sensor

Emergency stop switch

IGBT gate

Power supply

circuit

Set

Reset

24 V

Latch

Interruption

0 V

PCS

RS

EMR

M

~

90
80
70
60
50
40
30
20

10

0

Po

w

er (%)

1,250 V

76%

91%

61%

22%

Damper system

Energy-saving effect

Inverter system

Airflow (%)

10

20

30

40

50

60

70

80

90

100

Spikes in the terminal voltage are suppressed even when 
the wiring distance from the inverter to the motor is long

Содержание JX - 2

Страница 1: ...Compact and complete JX INVERTER Cost and eco friendly Communications built in Quality reliability you can depend on...

Страница 2: ...nput Cooling fan switch control RoHS Easy network integration The RS485 Modbus is built into the RJ45 port in the inverter front making it very easy to add inverters into the network without any extra...

Страница 3: ...y is supplied to the motor This hardware based solution is more reliable than other CPU dependent solutions Convenient and efficient The parameter settings of two different motors can be stored allowi...

Страница 4: ...cy reduction PTC thermistor input Cooling fan switch control PC configuration tool CX Drive CE UL cUL RoHS Ratings 200 V Class single phase 0 2 to 2 2 kW 200 V Class three phase 0 2 to 7 5 kW 400 V Cl...

Страница 5: ...phase 20 to 40 for 1 phase Approx 20 to 40 Approx 20 Cooling method Self cooling Forced air cooling Three phase JX A4004 A4007 A4015 A4022 A4040 A4055 A4075 Motor kW1 1 Based on a standard 3 Phase sta...

Страница 6: ...n V f characteristic selection upper lower limit 16 step speeds starting frequency adjustment jogging operation carrier frequency adjustment PID control frequency jump analog gain bias adjustment S sh...

Страница 7: ...55 2 2 2 2 A2022 2 2 4 3 7 A2037 2 5 5 A2055 2 164 235 180 250 167 5 1 6 77 5 4 2 7 5 A2075 2 Three phase 400 V 0 4 A4004 2 98 176 110 189 130 5 2 6 28 1 5 0 75 A4007 2 157 5 6 55 2 3 1 5 A4015 2 2 4...

Страница 8: ...101 66 5 7 5 2 1 22 AX RC27000030 DE 105 1 60 AX RC14000047 DE AX RC10100069 DE 116 1 95 AX RC06400116 DE 108 135 133 120 82 6 5 9 5 9 5 3 70 AX RC04410167 DE 120 152 136 135 94 7 5 20 AX RC03350219...

Страница 9: ...move the short circuit bar between 1 and P 2 when a DC reactor is connected P N Regenerative braking unit connection terminal Connect optional regenerative braking units If a braking torque is require...

Страница 10: ...i function Input selection 5 Factory setting Multi step speed reference 1 L Multi function Input selection common Analog input signal H Frequency reference power supply 10 VDC 10 mA max O Voltage freq...

Страница 11: ...RC03510093 DE 9 3 3 51 1 5 AX RC14000047 DE 4 7 14 0 2 2 AX RC02510138 DE 13 8 2 51 2 2 AX RC10100069 DE 6 9 10 1 3 7 AX RC01600223 DE 22 3 1 60 4 0 AX RC06400116 DE 11 6 6 40 5 5 AX RC01110309 DE 30...

Страница 12: ...JX A2007 E 1 5 7 1 JX A2015 E 2 2 10 JX A2022 E 3 7 15 9 JX A2037 E 5 5 24 JX A2055 E 7 5 32 JX A2075 E Three phase 400 V 0 4 1 5 JX A4004 EF 0 75 2 5 JX A4007 EF 1 5 3 8 JX A4015 EF 2 2 5 5 JX A4022...

Страница 13: ...DE JX A4022 AX RC10100069 DE JX A2037 AX RC01600223 DE JX A4040 AX RC06400116 DE JX A2055 AX RC01110309 DE JX A4055 AX RC04410167 DE JX A2075 AX RC00840437 DE JX A4075 AX RC03350219 DE Model Diameter...

Страница 14: ...mron com tr United Kingdom Tel 44 0 870 752 08 61 www industrial omron co uk More Omron representatives www industrial omron eu Although we strive for perfection Omron Europe BV and or its subsidiary...

Отзывы: