background image

112

Motion controllers

JUSP-NS600

 - 

indexer unit

Specifications

Item

Details

Type

JUSP-NS600

Applicable servo drive

All SGDH-

@@@

E SERVOPACKs

Installation method

Mounted on the SGDH servo drive side: CN10.

Basic specifications

Power supply method

Supplied from the servo drive control power supply

Power consumption

2.6 W

Control specifications

Program table

Program table positioning by designating the starting step by the contact input 
(maximum 128 steps)

Serial communications

Serial commands in ASCII codes
Communications specifications: RS422 / RS485 (maximum 50 m (164.0 ft))

RS232C (maximum 3 m (9.84 ft))

Connection: Multi-drop method (maximum 16 axes)
Baud rate: 9600, 19200, 38400bps

Command table

Positioning by designating the command table by the contact input
(maximum 128 points)

Zero-point return

3 types

Other functions

External positioning, JOG speed table operation (maximum 16 speeds)

I/O signals

Input

Servo drive

S-ON (Servo ON)
P-OT (forward run prohibited), N-OT (reverse run prohibited)
DEC (zero-point return deceleration LS)
RTRG (external positioning signal)

INDEXER module

MODE0/1 (mode signal)
START/HOME (start signal / zero-point return execution)
PGMRES/JOGP (program reset / motor forward rotation)
SEL0/JOGN (program starting step designation / motor reverse rotation)
SEL1 to SEL4 / JOG0 to JOG3 (program starting table selection / JOG speed table selection)

Output

Servo drive

ALM (servo alarm)
WARN (warning)
BK (brake interlock)
S-RDY (servo ready)
ALO1, ALO2, ALO3 (alarm codes)

INDEXER module

INPOSITION (positioning completed)
POUT0 to POUT4 (programable outputs)

Y203-EN2-02-Katalog.book  Seite 112  Mittwoch, 24. Mai 2006  2:22 14