40
Motor Contactor
J7KN
Utilization category AC4
Switching of squirrel cage motors, inching
Rated operational power
of three-phase motors
50-60Hz
220-230V
kW
3
4
5
5
6
8,5
11
12,5
18,5
18,5
240V
kW
3
4
5
5
7
9
11,5
13,5
19
19
380-400V
kW
4
5,5
7,5
7,5
11
15
18,5
22
30
30
415V
kW
4,5
6
8,5
8,5
12
16
20
24
33
33
440V
kW
4,5
6
8,5
8,5
12
16
20
24
33
33
500V
kW
5,5
7,5
10
10
15
18,5
18,5
30
37
37
660-690V
kW
5,5
7,5
10
10
15
18,5
18,5
30
37
37
1000V
kW
-
-
-
-
-
-
-
-
-
Utilization category AC 5a
Switching of gas discharge lamps
Rated operational current I
e
per pole at 220/230V
Fluorescent lamps,
uncompensated and serial compensated
A
20
20
25
25
40
52
64
88
96
104
parallel compensated
A
7
9
9
9
18
22
22
30
40
45
dual-connection
A
22,5
22,5
28
28
45
58
72
98
108
117
Metal halide lamps
*2
,
uncompensated
A
12
15
19
19
30
39
48
66
72
78
parallel compensated
A
7
9
9
9
18
22
22
30
40
45
Mercury-vapour lamps
*3
,
uncompensated
A
22,5
25
28
28
45
58
72
99
108
117
parallel compensated
A
7
9
9
9
18
22
22
30
40
45
Mixed light lamps
*4
A
20
20
25
25
40
52
64
88
96
104
Utilization category AC 5b
Switching of incandescent lamps
*5
Rated operational current I
e
per pole at 220/230V
A
12,5
12,5
12,5
12,5
25
31
31
43
56
56
Utilization category AC 6a
Transformer primary switching
at inrush
n
30
30
30
30
30
30
30
30
30
30
Rated operational current I
e
400V
A
4,5
5,5
7,5
7,5
10,5
13,5
13,5
20
27
33
Rated operational power
dependent on inrush n
220-230V
kVA
1,8
2,2
3
3
4,2
5,4
5,4
8
10,7
13
240V
kVA
1,9
2,3
3,1
3,1
4,3
5,6
5,6
8,3
11,2
13,5
380-400V
kVA
3,1
3,8
5,2
5,2
7,3
9,3
9,3
13,5
18,5
22,5
For different inrush-factors x
use the following formula:
Px=Pn*(n/x)
415-440V
kVA
3,4
4,2
5,7
5,7
8
10,2
10,2
15
20,5
25
500V
kVA
3,9
4,8
6,5
6,5
9
11,5
11,5
17
23
28
660-690V
kVA
5,4
6,5
9
9
12,5
16
16
24
32
39
Utilization category AC 6b
Switching of three-phase capacitor banks
Maximum inrush current (peak val-
ue) as multiple k of the capacitor
rated current
k
35
25
20
20
25
25
25
25
25
20
Rated operational current I
e
500V
A
8
12
15,5
15,5
23
32
32
45
60
70
Rated operational power
(sin
1)
220-230V
kVAr 3
4,5
6
6
8,5
12
12
17
24
28
240V
kVAr 3,5
5
6,5
6,5
9,5
13
13
18,5
25
29
380-400V
kVAr 5
7,5
10
10
15
20
20
29
39
46
For different multiples x
use the following formula:
Px=Pk*(k/x)
415-440V
kVAr 5,5
8
11
11
16
22
22
32
43
50
500V
kVAr 7
10
13
13
20
26
26
39
50
58
660-690V
kVAr 7
10
13
13
20
26
26
40
50
58
Switching of detuned capacitors
Rated operational current I
e
690V
A
8
13
18
20
28
36
42
48
72
105
1)
Rated operational power
220-230V
kVAr 2,9
5
7
7,5
11
14
16
20
28
33
240V
kVAr 3,1
5,4
7
8
11
14
17
20
28
36
380-400V
kVAr 5
9
12,5
13
20
25
27,5
33,3
50
75
1)
415-440V
kVAr 5,5
9,5
13
14
22
27
30
36
53
75
1)
500V
kVAr 6
11
15
17
25
30
36
40
60
75
660-690V
kVAr 8
15
20
22
33
41
48
55
82
100
Utilization category DC1
Switching of resistive load
Time constant L/R 1ms
Rated operational current I
e
1 pole24V A
20
25
32
32
50
65
80
110
120
130
60V A
20
25
32
32
50
65
80
110
120
130
110V A
6
6
6
6
10
10
10
12
12
12
220V A
0,8
0,8
0,8
0,8
1,4
1,4
1,4
1,4
1,4
1,4
3 poles in series 24V A
20
25
32
32
50
65
80
110
120
130
60V A
20
25
32
32
50
65
80
110
120
130
110V A
20
25
32
32
50
65
80
110
120
130
220V A
16
20
20
20
30
35
35
63
80
80
Main Contacts
Type
J7KN-10
J7KN-14
J7KN-18
J7KN-22
J7KN-24
J7KN-32
J7KN-40
J7KN-50
J7KN-62
J7KN-74