Nomenclature
Chapter 3-1
3-1
Nomenclature
Note
For safety’s reasons, the reset will not work while a RUN command (forward
or reverse) is in effect. Wait until the RUN command is OFF before resetting
the Inverter.
Appearance
Name
Function
Data display
Displays relevant data items, such as frequency reference, output frequency,
and parameter set values.
FREQ adjuster
Sets the frequency reference within a range between 0 Hz and the maximum
frequency.
FREF indicator
The frequency reference can be monitored or set while this indicator is lit.
FOUT indicator
The output frequency of the Inverter can be monitored while this indicator is lit.
IOUT indicator
The output current of the Inverter can be monitored while this indicator is lit.
MNTR indicator
The values set in U01 through U10 are monitored while this indicator is lit.
F/R indicator
The direction of rotation can be selected while this indicator is lit, when
operating the Inverter with the RUN Key.
LO/RE indicator
The operation of the Inverter through the Digital Operator or according to the
parameters set is selectable while this indicator is lit.
Note
Note This status of this indicator can be only monitored while the
Inverter is in operation. Any RUN command input is ignored while this
indicator is lit.
PRGM indicator
The parameters in n01 through n79 can be set or monitored while this
indicator is lit.
Note
While the Inverter is in operation, the parameters can be only monitored
and only some parameters can be changed. Any RUN command input
is ignored while this indicator is lit.
Mode Key
Switches the setting and monitor item indicators in sequence.
Parameter setting being made is canceled if this key is pressed before
entering the setting.
Increment Key
Increases multi-function monitor numbers, parameter numbers, and
parameter set values.
Decrement Key
Decreases multi-function monitor numbers, parameter numbers, and
parameter set values.
Enter Key
Enters multi-function monitor numbers, parameter numbers, and internal data
values after they are set or changed.
RUN Key
Starts the Inverter running when the CIMR-J7AZ is in operation with the
Digital Operator.
STOP/RESET Key
Stops the Inverter unless n06 is set to disable the STOP Key.
Functions as a Reset Key when an Inverter error occurs. (See note.)
Data display
Keys
Indicators
Setting/Monitor item indicators
FREQ adjuster
Содержание J7 series
Страница 12: ...XII...
Страница 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Страница 47: ...33 CHAPTER 3 Preparing for Operation and Monitoring 3 1 Nomenclature 34 3 2 Outline of Operation 35...
Страница 54: ...40 Outline of Operation Chapter 3 2...
Страница 102: ...88 Other Functions Chapter 6 7...
Страница 158: ...144 Option Specifications Chapter 9 3...
Страница 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Страница 172: ...158 List of Parameters Chapter 10...
Страница 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...