background image

OMRON HEALTHCARE Co., Ltd.

53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN

Distributed by: 

OMRON HEALTHCARE, INC.

1925 West Field Court, Lake Forest, IL 60045 U.S.A.

OmronHealthcare.com
©2019 OMRON HEALTHCARE, INC.

Made in Japan

Содержание HeartGuide BP8000-M

Страница 1: ...LTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Distributed by OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A OmronHealthcare com 2019 OMRON HEALTHCARE INC Made...

Страница 2: ...Model BP8000 M Instruction Manual 4615954 8A Instruction Manual...

Страница 3: ...ng the Battery 19 2 2 Installing the Cuff Sleeve 21 2 3 Wearing the Monitor on the Left Wrist 21 2 4 Turn Your Monitor On 23 3 Using Your Monitor without a Smart Device 24 3 1 Taking a Blood Pressure...

Страница 4: ...to the Default Settings 51 7 4 Turning Off Your Monitor 52 8 Error Messages and Troubleshooting 53 8 1 Error Messages 53 8 2 Troubleshooting 57 9 Maintenance 59 9 1 Maintenance 59 9 2 How to Replace...

Страница 5: ...or displays a digital reading of blood pressure This monitor can also track measurements such as steps calories burned hours slept and awake time Safety Instructions This instruction manual provides y...

Страница 6: ...arning signal with readings Environments of Use Home Patient Population Adult Receiving and Inspection Remove this monitor from the packaging and inspect for damage If this monitor is damaged DO NOT U...

Страница 7: ...as prescribed by your physician ONLY a physician is qualified to diagnose and treat high blood pressure DO NOT use this monitor on an injured wrist or a wrist under medical treatment DO NOT wear this...

Страница 8: ...g cable away from infants toddlers or children This product contains small parts that may cause a choking hazard if swallowed by infants toddlers or children Data Transmission This product emits radio...

Страница 9: ...NOT use it in any other devices DO NOT recharge the rechargeable battery once it has been removed from this monitor DO NOT dispose of the battery in a fire DO NOT crush or puncture the battery becaus...

Страница 10: ...irritation or discomfort DO NOT use this device if you have a metal allergy Keep this monitor clean If this monitor is causing skin irritation due to sweat or contamination stop using it and consult...

Страница 11: ...essary because bruising due to blood flow interference may occur ONLY inflate the cuff when the band is applied to your wrist Remove the band if it does not start deflating during a blood pressure mea...

Страница 12: ...ironments such as medical clinics or physician offices DO NOT use this monitor with other medical electrical ME equipment simultaneously This may result in incorrect operation of the monitor and or ca...

Страница 13: ...ormation of operating and storage transport temperature refer to section 11 DO NOT use this monitor after the durable period has ended Refer to section 11 DO NOT crease the band excessively DO NOT use...

Страница 14: ...ch it DO NOT place it under heavy objects Wipe any dust off of the AC adapter Unplug the AC adapter when not in use Unplug the AC adapter before cleaning this monitor ONLY use the AC adapter and charg...

Страница 15: ...g clip Model HEM CLIP 01 AC adapter Model HHP AM02 Charging cable Model HHX CB07U Replacement cuff sleeve Model HEM CUCV 01 2 pcs Instruction manual Quick start guide Paper sizing guide 1 Know Your Mo...

Страница 16: ...14 a Display b START STOP button c FORWARD button d HOME button Press this button from any screen to go back to HOME screen e Band f Charging port g Cuff 1 2 Monitor 1 Know Your Monitor a b c d e g f...

Страница 17: ...ymbol Appears when your data needs to be transferred because the stored memory is either almost or completely full Once you pair your monitor with your smart device transfer your readings immediately...

Страница 18: ...rregular rhythm is detected 2 or more times during a blood pressure measurement An irregular heartbeat rhythm is defined as a rhythm that is 25 less or 25 more than the average rhythm detected while y...

Страница 19: ...gs in its internal memory as follows Blood pressure measurements Up to 100 readings Activity data Up to 7 days Sleep data Up to 7 times Event data Up to 100 items Battery Symbols Indicates current bat...

Страница 20: ...Hg or 80 89 mmHg Stage 2 140 mmHg or 90 mmHg Hypertensive crisis 180 mmHg and or 120 mmHg Individuals with Systolic BP and Diastolic BP in 2 categories should be designated to the higher BP category B...

Страница 21: ...ours to fully charge once the battery is empty 1 Plug the smaller end of the charging cable into the charging clip 2 Lift the band and connect the clip to the charging port of your monitor Make sure t...

Страница 22: ...ls FULL Battery Life Your monitor will last up to 2 days per charge depending on use and storage condition Refer to Battery Life Information page 65 for the terms of the battery life Note The battery...

Страница 23: ...over the cuff by pulling the cuff sleeve toward the charging port Charging port 3 Cover the charging port 2 3 Wearing the Monitor on the Left Wrist Blood pressure can differ between the right and left...

Страница 24: ...a snug fit prior to measuring not too tight not too loose Your index finger should NOT easily slide between the band and your wrist 2 5 3 c m 1 i n c h Make sure that the cuff is positioned correctly...

Страница 25: ...app for pairing Note You can use your monitor without pairing to your smart device Refer to section 3 page 24 To take activity measurements and sleep measurements pair your monitor with your smart de...

Страница 26: ...ther medical electrical ME equipment simultaneously This may result in incorrect operation of the monitor and or cause an inaccurate reading Remain still and DO NOT talk while taking a blood pressure...

Страница 27: ...the morning and in the evening is recommended Remember to have a record of your blood pressure and pulse readings for your physician A single measurement does not provide an accurate indication of yo...

Страница 28: ...is important 1 Find the positioning mark on the band Positioning mark 2 Position the positioning mark on the center of your wrist align with your middle finger The positioning mark may be covered by...

Страница 29: ...ur feet flat and your legs uncrossed Relax your wrist and hand Do not bend your wrist back clench your fist or bend your wrist forward 3 1 4 Taking a Blood Pressure Measurement Note To stop the measur...

Страница 30: ...onds the monitor will start a measurement and the cuff will start to inflate If the monitor is too high above your heart your blood pressure will be artificially low If the monitor is too low below yo...

Страница 31: ...ure and pulse rate the cuff automatically deflates Your blood pressure and pulse rate are displayed If either the systolic or the diastolic reading is high refer to sub section 1 4 the number and indi...

Страница 32: ...If it does not vibrate your monitor may not be at the correct height and position relative to your heart Due to differences in individual size and physique this feature may not be helpful in all cases...

Страница 33: ...el Your body moved during measurement Do not move and take another measurement Irregular heartbeats are detected Irregular heartbeat Warning DO NOT adjust medication based on your readings from this b...

Страница 34: ...e app all future measurements will include the date and time when you transfer If you do not pair the monitor any measurements you take will not include the date and time Review the list of compatible...

Страница 35: ...he app contact customer service Refer to section 13 page 69 Error Note HeartAdvisor is the only app that we recommend that you use with your monitor to transfer data correctly Be aware that OMRON will...

Страница 36: ...s Open the app on your smart device and follow the instructions Note Make sure your monitor is within 16 ft 5 m of your smart device When the Bluetooth OFF symbol appears on the display of your monito...

Страница 37: ...age 32 The personal information you are asked to provide on the app is to help calculate measurements accurately You can also set your daily target steps on the app 2 Set your stride length The initia...

Страница 38: ...TART END 3 Wear your monitor wherever you go When your target steps are achieved the achievement screen appears 5000 steps Congratulations 4 Press the FORWARD button to view the readings stored in the...

Страница 39: ...n not walking Carrying a bag Extremely slow arm movements Doing housework without walking Walking at an Inconsistent Pace Shuffling or wearing sandals Constantly starting and stopping walking or movin...

Страница 40: ...s in section 6 page 45 for more information Note Only wear your monitor on your wrist During the sleep mode your monitor does not count your steps If you set the sleep mode manually you cannot take a...

Страница 41: ...tton to start the sleep measurement Sleep mode Sleep mode ON 3 Get up Your monitor will detect rising and disable the sleep mode automatically Note If the Auto sleep function is disabled press and hol...

Страница 42: ...m Brian Message Mail from mail omron com Email Note Refer to HeartAdvisor for compatible email apps or any other information Your monitor cannot receive a notification from your smart device during th...

Страница 43: ...eminder can only be set on the app 11 30AM 11 30AM 11 30AM Note To stop the vibration press any button If the reminder time comes while taking a blood pressure measurement the alert will start after t...

Страница 44: ...ctivity as an Event such as time you ate took a medicine exercised or had another event Note The recorded time of your events can be viewed on the app only 1 Press and hold the FORWARD button for more...

Страница 45: ...Press the FORWARD button THU 17 8 38 2 Press the FORWARD button one by one The display of your readings changes as below For activities and sleep the ring around the reading describes the level of ac...

Страница 46: ...118 8 38 Alternating pulse symbols display Symbol Meaning This monitor is not at the correct height Irregular heartbeats are detected Movement during measuring Meaning of each display item Activities...

Страница 47: ...at helps us stay healthy Aerobic steps are counted separately when walking more than 60 steps per minute and more than 10 minutes successively If a rest of less than 1 minute is taken after a continuo...

Страница 48: ...p time Wake up time Time until you fall asleep Sleep period time Time of movement at restless level 2 during sleep period time Sleep mode enabled Sleep mode disabled 0 1 2 Total amount of sleep period...

Страница 49: ...n for more than 3 seconds ON OFF L R THU 17 8 38 7 1 1 Enabling Disabling Heart Zone Indicator 1 Press the START STOP button for heart zone indicator setting ON OFF L R 2 Press the START STOP button t...

Страница 50: ...ME button for wrist setting ON OFF L R 2 Press the START STOP button if you wear your monitor on the left wrist or press the HOME button if you wear the monitor on the right wrist Note Left is set by...

Страница 51: ...Entering Pairing Mode Press and hold the HOME button for more than 3 seconds Refer to sub section 4 1 page 32 to pair your monitor with your smart device Note Bluetooth will be enabled automatically...

Страница 52: ...se areas For further information on potential restrictions refer to documentation on the Bluetooth usage by the FCC Press and hold the HOME button for at least 3 seconds when your monitor is in the pa...

Страница 53: ...7 seconds When the confirmation screen appears press the START STOP button to restore your monitor ClearAll Cancel Cleared THU 17 8 38 Note Reverting to its default setting of your monitor does not d...

Страница 54: ...delete your reading or any information in the monitor and the app however your step numbers from the past hour may be lost After restarting open HeartAdvisor app to communicate The date and time will...

Страница 55: ...Remove your monitor Wait for 2 3 minutes and then take another measurement Repeat the steps in sub section 3 1 page 25 If this error continues to appear we recommend that you consult with your physici...

Страница 56: ...checking the app contact customer service Refer to section 13 page 69 Please see the manual Error 1 The band is not applied correctly Apply the band correctly then take another measurement Refer to s...

Страница 57: ...nitor while taking a measurement Please see the manual Error 4 You move or talk during a measurement Vibrations disrupt a measurement Remain still and do not talk during a measurement Please see the m...

Страница 58: ...mperature If the error appears again contact customer service Refer to section 13 page 69 The monitor has malfunctioned Please see the manual Error 9 The band may be applied too tightly Apply the band...

Страница 59: ...ear too high or too low Blood pressure varies constantly Many factors including stress time of day and or how you apply the band may affect your blood pressure Review sub section 3 1 page 25 Any other...

Страница 60: ...ly and contact customer service Refer to section 13 page 69 The operating time is short or the monitor does not operate even when the battery is fully charged This may be due to the life of the rechar...

Страница 61: ...will void the user warranty Caution DO NOT disassemble or attempt to repair this monitor or other components 9 2 How to Replace the Cuff Sleeve Clean the cuff sleeve when it becomes dirty once a week...

Страница 62: ...oft dry cloth or a soft cloth moistened with neutral soap to clean your monitor and then wipe them with a dry cloth Do not wash or immerse your monitor in water Do not use gasoline thinners or similar...

Страница 63: ...onitor for a while after extended wear Be careful not to let chemical products such as lotions oils skin creams or cosmetics collect on the band If this happens wipe them immediately otherwise it may...

Страница 64: ...arging clip Model HEM CLIP 01 AC adapter Model HHP AM02 Charging cable Model HHX CB07U Cuff sleeve Model HEM CUCV 01 For further information visit our website at OmronHealthcare com 10 Optional Access...

Страница 65: ...s communication Frequency range 2 4 GHz 2400 2483 5 MHz Modulation GFSK Effective radiated power 20 dBm Operation mode Continuous operation IP classification Monitor IP22 AC adapter IPX0 Rating DC 3 8...

Страница 66: ...to 35 C Storage conditions 4 to 104 F 20 to 40 C 10 to 90 RH non condensing Transport conditions 4 to 140 F 20 to 60 C 10 to 90 RH non condensing Weight Approximately 4 1 oz 115 g Dimensions Case dia...

Страница 67: ...ng per day 8 hour sleep measurement per day 96 times of button pressing per day 16 times of incoming call per day 1 time of ringing alarm per day 16 hour Bluetooth communication per day The battery li...

Страница 68: ...he clinical validation study K5 was used on 85 subjects for determination of diastolic blood pressure This monitor is comply with the requirements of ISO 81060 2 2013 This monitor has not been validat...

Страница 69: ...ate on the same frequency band as this product there is a possibility that interference may occur If interference occurs stop the operation of the other devices or relocate this product away from othe...

Страница 70: ...harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Страница 71: ...cription of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested THE FOREGOI...

Страница 72: ...ther documentation in accordance with this EMC standard is available at OmronHealthcare com emc Refer to the EMC information for BP8000 M on the website The Bluetooth word mark and logos are registere...

Отзывы: