background image

Solid-state timer

 

H3RN

B-97

Ti

m

e

rs

Solid-state timer

H3RN

Ultra-slim Timer for G2R Relay Socket

• Pin configuration compatible with G2R Relay and mounts to the 

P2R/P2RF Socket.

• Standard multiple time ranges and multiple operating modes.

• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt-

age, and EMC Directives.

Model Number Structure

Model Number Legend

1. Output

1:

SPDT

2:

DPST-NO

2. Time Range

None: Short-time range (0.1 s to 10 min)
1:

Long-time range (0.1 min to 10 hrs)

Ordering Information

List of Models

Accessories (Order Separately)

Connecting Socket

H3RN-

@@

1  2

Supply voltage

Time-limit contact

Short-time range model

(0.1 s to 10 min)

Long-time range model

(0.1 min to 10 h)

24 VAC;
12, 24 VDC

SPDT

H3RN-1

H3RN-11

DPST-NO

H3RN-2

H3RN-21

Note: 

  Specify both the model number and supply voltage when ordering.

Example: H3RN-1   24 VAC

Supply voltage

Timer

Track mounting/Front connecting socket

Back connecting socket

H3RN-1/-11

P2RF-05-E

P2R-057P

H3RN-2/-21

P2RF-08-E

P2R-087P

Содержание H3RN

Страница 1: ...O 2 Time Range None Short time range 0 1 s to 10 min 1 Long time range 0 1 min to 10 hrs Ordering Information List of Models Accessories Order Separately Connecting Socket H3RN 1 2 Supply voltage Time limit contact Short time range model 0 1 s to 10 min Long time range model 0 1 min to 10 h 24 VAC 12 24 VDC SPDT H3RN 1 H3RN 11 DPST NO H3RN 2 H3RN 21 Note Specify both the model number and supply vo...

Страница 2: ... H3RN 21 Accuracy of operating time 1 FS max 1 s range 1 10 ms max Setting error 15 50 ms FS max Reset time Min power opening time 12 24 VDC 0 1 s max including halfway reset 24 VAC 0 5 s max including halfway reset Influence of voltage 2 FS max Influence of temperature 2 FS max Insulation resistance 100 MΩ min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between operating circuit a...

Страница 3: ... level 3 2 kV I O signal line level 4 Immunity Surge IEC51000 4 5 1 kV line to line level 3 2 kV line to ground level 3 Approved standards UL508 CSA C22 2 No 14 Conforms to EN61812 1 IEC60664 1 4 kV 2 Output category according to IEC60947 5 1 Item H3RN 1 H3RN 2 H3RN 11 H3RN 21 OUT PW Bottom View H3RN 1 H3RN 11 H3RN 2 H3RN 21 DIN Indication DIN Indication OUT PW Bottom View Timer circuit Timer circ...

Страница 4: ...t NC 4 2 Time limit contact NO 4 3 Run Power indicator PW Output indicator OUT Power 1 8 Time limit contact NO 4 3 5 6 Run Power indicator PW Output indicator OUT Flicker OFF start Power Output Power 1 5 Time limit contact NC 4 2 Time limit contact NO 4 3 Run Power indicator PW Output indicator OUT Power 1 8 Time limit contact NO 4 3 5 6 Run Power indicator PW Output indicator OUT Flicker ON start...

Страница 5: ...operating modes Nomenclature Model Time range Time setting range Setting Factory set H3RN 1 H3RN 2 1 s 0 1 to 1 s Yes 10 s 1 to 10 s No 1 min 0 1 to 1 min No 10 min 1 to 10 min No H3RN 11 H3RN 21 1 min 0 1 to 1 min Yes 10 min 1 to 10 min No 1 h 0 1 to 1 h No 10 h 1 to 10 h No Operating mode Setting Factory set ON delay Yes Interval No Flicker OFF start No Flicker ON start No Run Power Indicator Gr...

Страница 6: ...se sockets replace with 05 for SPDT or 08 for DPST NO The P2RF cannot be used because the hook is a different shape P2RF E Socket 79 5 see note 1 83 5 see note 2 80 9 see note 1 84 9 see note 2 P2R 7P Socket Note 1 The value shown indicates the dimension for the P2RF 05 E with the PFP N Mounting Rail The value is 71 5 mm when using the PFP N 2 2 The value shown in parentheses indicates the di mens...

Страница 7: ...ed of an SPST NC contact Do not set to the minimum setting in the flicker modes otherwise the contact may be damaged Do not use the H3RN in places where there is excessive dust corro sive gas or direct sunlight Make sure that there is a space of 3 mm or more between any H3RN Models next to each other When using the P2RF E Socket a space of 3 mm or more will be secured If a space of 3 mm or more is...

Страница 8: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L090 E1 02 ...