Motor Time Switch

H2F-D

ON/OFF Control 48 Times per Day in 15-min 
Increments

The H2F-D is a Low-cost Time Switch for Affordable 
Operation in a Compact DIN 72 x 72-mm Body. 
Choose the Ideal Model to Match the Application.

• Just insert the trippers for easy setup.

• Make exact time settings using the dial.

• Three mounting methods.

• Lineup includes models with power interruption backup.

• Safety standards: UL and CSA (except for H2F-30/-31).

 

The H2F-DM, -DMC, -DMF, -DMFC, -30, and -31 use 
nickel metal hydride batteries. 

Dispose of the batteries at a battery recycling location.
Replacement batteries are not available for previous H2F 
Time Switches from March 2006 and earlier. Replace the 
entire H2F Time Switch. Refer to 

Notice

 on page 7.

P S

 

72 mm

72 mm

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

Ordering Information

Note:

Always use the Time Switch with the Y92S-42 Battery mounted.

Accessories (Order Separately)

Control 

cycle

Drive 

method

Power 

interruption 

backup

Power supply 

voltage

Mounting

method

Flush mounting

Surface mounting/

track mounting

Control

output

SPST-NO

SPDT

SPST-NO

SPDT

Daily 
(24 hours)

Synchronous 
motor

No

100/110/120 VAC

Model

H2F-D

H2F-DC

H2F-DF

H2F-DFC

200/220/240 VAC

H2F-D

H2F-DC

H2F-DF

H2F-DFC

Quartz motor 
(See note.)

Yes

100 to 240 VAC

H2F-DM

H2F-DMC

H2F-DMF

H2F-DMFC

12 to 24 VDC

H2F-30

---

---

H2F-31

Name

Model

Trippers (1 set for ON and OFF) (See note 1.) Y92S-21

Battery (See note 2.)

Y92S-42

Note: 1.

Three gold-colored trippers for ON and three silver-colored 
trippers for OFF are enclosed with the H2F-D. Separately order 
trippers if more are required.

2.

The battery is built into the H2F-D. When the battery is nearing the 
end of its service life, order the model number listed at the left.

Содержание H2F-D

Страница 1: ... models that have been certified for safety standards refer to your OMRON website Ordering Information Note Always use the Time Switch with the Y92S 42 Battery mounted Accessories Order Separately Control cycle Drive method Power interruption backup Power supply voltage Mounting method Flush mounting Surface mounting track mounting Control output SPST NO SPDT SPST NO SPDT Daily 24 hours Synchronou...

Страница 2: ... to 24 VDC Control output 15 A at 250 VAC resistive load Ambient operating temperature 10 to 55 C with no icing Ambient operating humidity 35 to 85 Type Daily Item Synchronous motor Quartz motor Operating time deviation See note 1 Voltage influence and temperature influence 3 min max Setting error See note 2 3 min max Cyclic error 3 min max Power interruption backup time 180 h min See note 3 Insul...

Страница 3: ... F Location of yellow lever Flush Mounting Surface Mounting DIN Track Mounting 72 72 45 mm H W D below faceplate 29 mm 95 72 50 mm H W D Panel Cutout Dimensions according to DIN 43700 Panel thickness 1 to 3 2 mm Note The mounting adapter and mounting screws are enclosed Mounting Screw Dimensions Adapter 68 0 7 0 68 0 7 0 17 5 27 5 Screw size M3 45 enclosed 61 0 2 Two M3 60 0 2 ...

Страница 4: ...inal Nomenclature H2F D H2F DF H2F DC H2F DFC H2F DM H2F 30 H2F DMF Note On the H2F 30 12 to 24 VDC terminal number 2 is positive and terminal number 3 is negative H2F DMC H2F DMFC H2F 31 Note On the H2F 31 12 to 24 VDC terminal number 2 is positive and terminal number 3 is negative Mounting Holes ON OFF operation selector knob Dial rotation direction clockwise Manual switch Time setting knob Hole...

Страница 5: ...ll units are in millimeters unless otherwise indicated 72 72 65 5 45 65 5 1 3 17 16 H2F D C H2F DM C H2F 30 Note The terminal screws are M3 5 72 72 95 2 2 50 9 6 6 29 H2F DF C H2F DMF C H2F 31 Note The terminal screws are M3 5 ...

Страница 6: ... the manual switch is set to AUTO Load 1 terminals 4 and 5 will turn ON and load 2 terminals 5 and 6 will turn OFF when the manual switch is set to ON Check the output indicator when returning operation to AUTO If the knob has been touched or the output indicator has changed because of vibration or shock turn the knob switch the output and then return operation to AUTO Output Indicator and ON OFF ...

Страница 7: ... excessive discharge if the H2F is left unused for an extended period with the battery mounted Be sure to remove the battery before storing the H2F Turn OFF the power supply before replacing the battery Use only the specified battery Y92S 42 The battery may leak or burst if any other battery is used possibly resulting in equipment damage or injury Other Precautions Always use a thermo switch on th...

Страница 8: ...rther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party ce...

Отзывы: