No.13S064-13
14/55
STC-CMC2MPOE / STC-CMB2MPOE / STC-CMB2MPOE-IR /
STC-CMC4MPOE / STC-CMB4MPOE / STC-CMB4MPOE-IR Product Specifications and User’s Guide
4.3
Mechanical Specifications
Model Number
STC-CMB2MPOE / STC-CMB4MPOE /
STC-CMB2MPOE-IR / STC-CMB4MPOE-IR
STC-CMC2MPOE / STC-CMC4MPOE
Dimensions
35 (W) x 35 (H) x 55.9 (D) mm (*1)
Optical Filter
No Optical Filter
No Optical Filter (*2)
Optical Center Accuracy
Positional accuracy in Horizontal and Vertical directions: +/- 0.3 mm
Rotational accuracy of Horizontal and Vertical: +/- 2.0 deg.
Material
Aluminum (AC)
Lens Mount
C mount
Connectors
RJ45 connector
Power- I/O connector: HR10A-7R-6PB (Hirose) or equivalent
Camera Mount Screws
Two 1/4” Tripod screw holes (One on top and bottom plate)
Eight M4 screws holes (Four on top and bottom plate)
Weight
Approximately 120 g
(*1) Excluding connectors
(*2) The color model with IR Cut Filter is optional mode. Please contact to sale representative.
4.4
Environmental Specifications
Model Number
STC-CMB2MPOE / STC-CMB4MPOE /
STC-CMB2MPOE-IR / STC-CMB4MPOE-IR
STC-CMC2MPOE / STC-CMC4MPOE
Operational
Temperature / Humidity
Minimum
Environmental Temperature -5 deg. C,
Environmental Humidity: 0 to 85 %RH (No condensation)
Maximum (*1)
Camera housing temperature (top plate) shall not 65 deg. C
(This corresponds to an environmental temperature of approxi40 deg. C)
Storage Temperature / Humidity
Environmental Temperature: -30 to +65 deg. C,
Environmental Humidity: 0 to 85 %RH (No condensation)
Vibration
20 Hz to 200 Hz to 20 Hz (5 min. / cycle), acceleration 10 G, XYZ 3 directions 30 min. each)
Shock
Acceleration 38 G, half amplitude 6 mseconds, XYZ 3 directions 3 times each
Standard Compliancy
EMS: EN61000-6-2, EMI: EN55011
RoHS
RoHS Compliance
(*1) When the camera using under the condition that e40 deg. C environmental temperature, please insure the
camera installs with the appropriate heat dissipation to keep the housing temperature less than +65 deg. C.
If camera has a mounted lens and a tripod with an aluminum plate, this could decrease the camera housing
temperature for heat dissipation.
Taking these steps will maintain the heat rating of the electronic components of the camera.
Upper side of camera
Measuring point