For full specifications and additional models please refer to www.omron-industrial.com
Safety network and units - Cat.-No. J150-E2-04
1
G9SX
Safety network and units
Flexible safety unit
G9SX-family modules can be connected by a logical "AND" function to
implement partial/global stopping of a machine. Solid-state outputs,
detailed LED diagnosis and clever feedback signals help to keep
maintenance easy. The line-up is completed by expansion units with
safe timing functions.
• Clear and transparent segmentation of safety functions by use of
unique "AND" connection
• Solid-state outputs for long life and relay outputs in extension box
available
• Detailed LED indications enable easy diagnosis
• Clever feedback signals for easy maintenance
• Category 4 according to EN954-1 and SIL 3 according to EN 61508
Ordering information
Advanced unit 1 logical AND input
Advanced unit 2 logical AND inputs
Basic unit
Expansion unit
Specifications
Power input
Inputs
Outputs
Safety outputs
Auxiliary outputs
No. of input
channels
Max. OFF-
delay time
*1
*1
The OFF-delay time can be set in 16 steps as follows: T15: 0/0.2/0.3/0.4/0.5/0.6/0.7/1/1.5/2/3/4/5/7/10/15 s, T150: 0/10/20/30/40/50/60/70/80/90/100/110/120/130/
140/150
Rated
voltage
Terminal block type
Model
Instantaneous
OFF-delayed
P channel MOS-FET
transistor output
P channel MOS FET
transistor outputs
PNP transistor
outputs
1 or 2 channels 0 to 15 s in
16 steps
24 VDC
Screw terminals
G9SX-AD322-T15-RT
Cage clamp terminals
G9SX-AD322-T15-RC
0 to 150 s in
16 steps
Screw terminals
G9SX-AD322-T150-RT
Cage clamp terminals
G9SX-AD322-T150-RC
Safety outputs
Auxiliary outputs
No. of input
channels
Max. OFF-
delay time
*1
*1
The OFF-delay time can be set in 16 steps as follows: T15: 0/0.2/0.3/0.4/0.5/0.6/0.7/1/1.5/2/3/4/5/7/10/15 s, T150: 0/10/20/30/40/50/60/70/80/90/100/110/120/130/
140/150
Rated
voltage
Terminal block type
Model
Instantaneous
OFF-delayed
P channel MOS-FET
transistor output
P channel MOS FET
transistor outputs
PNP transistor
outputs
1 or 2 channels 0 to 15 s in
16 steps
24 VDC
Screw terminals
G9SX-ADA222-T15-RT
Cage clamp terminals
G9SX-ADA222-T15-RC
0 to 150 s in
16 steps
Screw terminals
G9SX-ADA222-T150-RT
Cage clamp terminals
G9SX-ADA222-T150-RC
Safety outputs
Auxiliary outputs
No. of input
channels
Rated voltage
Terminal block type
Model
Instantaneous
OFF-delayed
P channel MOS FET
transistor output
---
PNP transistor output 1 or 2 channels 24 VDC
Screw terminals
G9SX-BC202-RT
Cage clamp terminals
G9SX-BC202-RC
Safety outputs
Auxiliary outputs
OFF-delay time Rated voltage
Terminal block type
Model
Instantaneous
OFF-delayed
4 PST-NO (contact) ---
1 (solid state)
PNP transistor output
---
24 VDC
Screw terminals
G9SX-EX401-RT
Cage clamp terminals
G9SX-EX401-RC
---
4 PST-NO (contact)
Synchronized
with
G9SX-AD - unit
Screw terminals
G9SX-EX041-T-RT
Cage clamp terminals
G9SX-EX041-T-RC
Item
G9SX-AD322-
@
G9SX-ADA222-
@
G9SX-BC202-
@
G9SX-EX-
@
Rated supply voltage 20.4 to 26.4 VDC (24 VDC -15% +10%)
Item
G9SX-AD322-
@
G9SX-ADA222-
@
G9SX-BC202-
@
Safety input
Operating voltage: 20.4 VDC to 26.4 VDC,
internal impedance: approx. 2.8 k
Ω
Feedback/reset input
Item
G9SX-AD322-
@
G9SX-ADA222-
@
G9SX-BC202-
@
Instantaneous safety output
OFF-delayed safety output
P channel MOS FET transistor output
Load current: Using 2 outputs or less: 1 A DC max.
Using 3 outputs or more: 0.8 A DC max.
P channel MOS FET transistor output
Load current: Using 1 output: 1 A DC max.
Using 2 outputs: 0.8 A DC max.
Auxiliary output
PNP transistor output
Load current: 100 mA max.
LISTED