Power Relay
G7J
A-59
Elec
trome
c
ha
ni
c
a
l
Re
la
ys
Specifications
■
Coil Ratings
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C with tolerances of +15%/–20% for AC rated current and
±
15% for DC coil resistance. (The values given for AC rated current apply at 50 Hz or 60 Hz.)
2.
Performance characteristic data are measured at a coil temperature of 23
°
C.
3.
The maximum voltage is one that is applicable to the Relay coil at 23
°
C.
■
Contact Ratings
Note:
The values in parentheses indicate values for a bifurcated contact.
■
Characteristics
Rated voltage
Rated current
Coil resistance
Must-operate
voltage
Must-release
voltage
Max. voltage
Power
consumption
AC
24 VAC
75 mA
---
75% max. of rated
voltage
15% min. of rated
voltage
110% of rated
voltage
Approx. 1.8 to
2.6 VA
50 VAC
36 mA
---
100 to 120 VAC
18 to 21.6 mA
---
200 to 240 VAC
9 to 10.8 mA
---
DC
6 VDC
333 mA
18
Ω
10% min. of rated
voltage
Approx. 2.0 W
12 VDC
167 mA
72
Ω
24 VDC
83 mA
288
Ω
48 VDC
42 mA
1,150
Ω
100 VDC
20 mA
5,000
Ω
Item
Resistive load (cos
φ
= 1)
Inductive load (cos
φ
= 0.4)
Resistive load
Contact mechanism
Double break
Contact material
Ag alloy
Rated load
NO: 25 A at 220 VAC (24 A at 230 VAC)
NC: 8 A at 220 VAC (7.5 A at 230 VAC)
NO: 25 A at 30 VDC
NC: 8 A at 30 VDC
Rated carry current
NO: 25 A (1 A)
NC: 8 A (1 A)
Max. switching voltage
250 VAC
125 VDC
Max. switching current
NO: 25 A (1 A)
NC: 8 A (1 A)
Contact resistance (see note 2)
50 m
Ω
max.
Operate time (see note 3)
50 ms max.
Release time (see note 3)
50 ms max.
Max. operating frequency
Mechanical: 1,800 operations/hr
Electrical:
1,800 operations/hr
Insulation resistance (see note 4)
1,000 M
Ω
min. (at 500 VDC)
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
4,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
10,000 V between coil and contact (with 1.2 x 50
µ
s impulse wave)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: NO:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
NC:10 to 26 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: NO:100 m/s
2
NC:20 m/s
2
Endurance
Mechanical: 1,000,000 operations min. (at 1,800 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr) (see note 5)
Error rate (see note 6)
100 mA at 24 VDC (bifurcated contact: 24 VDC 10 mA)
Ambient temperature
Operating: –25
°
C to 60
°
C (with no icing or condensation)
Ambient humidity
Operating: 5% to 85%
Weight
PCB terminal:
approx. 140 g
Screw terminal:
approx. 165 g