Solid State Relays
G3RV
3
■
Characteristics
■
Approved Standards
UL 508 (File No. E64562)
IEC/TUV (EN 62314)
Item
G3RV-SL700/500-A
G3RV-SL700/500-AL
G3RV-SL700/500-D
Operate time
1/2 of load power source cycle
+ 1 ms max.
1 ms max.
6 ms max.
Release time
40 ms max.
20 ms max.
60 ms max.
Output ON voltage drop
1.6 V rms max.
0.9 V max.
Leakage current
5 mA max. (at 200 VAC 50/60Hz)
10 µA max. (at 24VDC)
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric strength
AC2500V 50/60 Hz for 1 min between input and output
Vibration resistance
Malfunction: 10 to 55 to 10 Hz, 0.7-mm single amplitude
Shock resistance
300m/s
2
Ambient temperature
Storage:
−
30 to +100°C (with no icing or condensation)
Operating:
−
30 to +55°C (with no icing or condensation)
Ambient humidity
45 to 85%RH
Weight
Approx. 38 g
Pollution degree
2
Degree of protection according
to IEC 60529
IP20
Rated Impulse Withstand
Voltage
4.0kV / III
Load category
LC-A
DC-12
Overload Current Profile
1.5Ie 1.1Ue
5s ON, 10s OFF, 10cycles
Rated insulation Voltage
240V
Model
Input ratings
Contact ratings
G3RV-SL700/500-D Series
12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
24 VDC 3 A (Resistive Load) at 25°C
G3RV-SL700/500-A(L) Series
12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
240 VAC 2 A (Resistive Load) at 25°C
Input ratings
Contact ratings
12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
24 VDC 3 A (Resistive Load)
12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
240 VAC 2 A (Resistive Load)