manualshive.com logo in svg
background image

G3PJ

4

Dimensions

(Unit: mm)

Solid State Relays

SSRs with Screw Terminals
G3PJ-215B
G3PJ-225B
G3PJ-515B
G3PJ-525B

Two, M4

68

4.2

6.3

Two, 
M3.5

Note:

 Without terminal cover.

24

13

±

0.2

Two,
4.6 dia.

100 max.

90

±

0.2

84

22.5 max.

4.6 

×

 5.6

Oval hole

Note:

 With terminal cover.

4.5

90

±

0.3

Three, 4.5 dia. 
or M4

Mounting Holes

13

±

0.3

(90)

(85)

(100)

1

2

A1

A2

(+)

(

)

G3PJ-5

@@

B

1

2

A1

A2

(+)

(

)

G3PJ-2

@@

B

Terminal Arrangement/Internal Circuit Diagram

Output side

ti

u

cri

r

e

g

gir

T

Input side

Input side

Output side

ti

u

cri

r

e

g

gir

T

ti

uc

ri

c t

up

nI

ti

uc

ri

c t

up

nI

2-M4

26.5 41.5

4.2

6.1

Note:

 Without terminal cover.

68

13

±0.2

100 max.

90

±

0.2

84

22.5 max.

4.6 

×

 5.6

Oval hole

Note:

 With terminal cover.

4.5

(98.5)

(85)

(100)

90

±

0.3

Three, 4.5 dia. 
or M4

Mounting Holes

13

±

0.3

Two,
4.6 dia.

Terminal Arrangement/Internal Circuit Diagram

1

2

A1

A2

G3PJ-5

@@

B-PU

1

2

A1

A2

(

)

(

+

)

(

)

(

+

)

G3PJ-2

@@

B-PU

Output side

Output side

Input side

Input side

Trigger circuit

Trigger circuit

Input circuit

Input circuit

SSRs with push-in plus 
technology
G3PJ-215B-PU
G3PJ-225B-PU
G3PJ-515B-PU
G3PJ-525B-PU

Содержание G3PJ Series

Страница 1: ...t have been certified for safety standards refer to your OMRON website Refer to Safety Precautions on page 5 Input terminal Output terminal Insulation method Operation indicator Rated input voltage Ze...

Страница 2: ...C 50 60 Hz 75 to 528 VAC 50 60 Hz Close mounting 15 A Separate mounting 23 A 150 A 60 Hz 1 cycle 1 350A2 s G3PJ 525B PU Close mounting 25 A Separate mounting 27 A 220 A 60 Hz 1 cycle 6 600A2 s Model I...

Страница 3: ...0 0 20 40 60 80 100 Ambient temperature C Load current A G3PJ 225B PU G3PJ 525B PU G3PJ 215B PU G3PJ 515B PU 30 20 0 20 40 60 80 100 Ambient temperature C 40 30 20 12 10 8 5 0 G3PJ 215B PU G3PJ 515B P...

Страница 4: ...c r i c r e g g i r T Input side Input side Output side t i u c r i c r e g g i r T t i u c r i c t u p n I t i u c r i c t u p n I 2 M4 26 5 41 5 4 2 6 1 Note Without terminal cover 68 13 0 2 100 ma...

Страница 5: ...during transportation or mounting Doing so may result in deterioration of performance malfunction or failure Operating and Storage Environments Do not use or store the G3PJ in the following locations...

Страница 6: ...pull on it with excessive force Doing so may cause the wire disconnection Do not insert more than one wire into each terminal insertion hole To prevent wiring materials from smoking or ignition use t...

Страница 7: ...it is too thin use a flat blade screwdriver in the same way as when connecting stranded wire Connecting Stranded Wires Use the following procedure to connect the wires to the terminal 1 Hold a flat bl...

Страница 8: ...nnected to the load power supply The input cable must be less than 3 m 2 The G3PJ with Rated Load Voltage of 100 to 480 VAC 5 B model A capacitor must be connected to the input power supply A capacito...

Страница 9: ...is measured at an ambient temperature of 40 C The G3PJ uses a semiconductor to switch the load This causes the temperature inside the control panel to increase due to heating resulting from the flow o...

Страница 10: ...MEMO 10...

Страница 11: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Страница 12: ...L 60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron c...

Отзывы: