background image

12

Slim Relay

 

G2RV

Precautions

Precautions for Connection

Do not move the screwdriver up, down, or from side to side while it 
is inserted in the hole. Doing so may cause damage to internal 
components (e.g., deformation of the clamp spring or cracks in the 
housing) or cause deterioration of insulation.

Do not insert the screwdriver at an angle. Doing so may break the 
side of socket and result in a short-circuit.

Do not insert two or more wires in the hole. Wires may come in 
contact with the spring causing a temperature rise or be subject to 
sparks.

Insert the screwdriver along the hole wall as shown below.

If lubricating liquid, such as oil, is present on the tip of screwdriver, 
the screwdriver may fall out resulting in injury to the operator.

Insert the screwdriver into the bottom of the hole. It may not be 
possible to connect cables properly if the screwdriver is inserted 
incorrectly.

General Precautions

Do not use the product if it has been dropped on the ground. 
Dropping the product may adversely affect performance.

Confirm that the socket is securely attached to the mounting track 
before wiring. If the socket is mounted insecurely it may fall and 
injure the operator.

Ensure that the socket is not charged during wiring and 
maintenance. Not doing so may result in electric shock.

Do not pour water or cleansing agents on the product. Doing so 
may result in electric shock.

Do not use the socket in locations subject to solvents or alkaline 
chemicals.

Do not use the socket in locations subject to ultraviolet light (e.g., 
direct sunlight). Doing so may result in markings fading, rust, 
corrosion, or resin deterioration.

Do not dispose the product in fire.

Removing from Mounting Rail

To remove the socket from the mounting rail, insert the tip of 
screwdriver in the fixture rail, and move it in the direction shown 
below.

 

Screwdriver

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. J11E-EN-02B

Содержание G2RV - 1

Страница 1: ... 4 Relay Pushbutton 0 Without pushbutton 5 Input Voltage Note LED indicator available on socket Ordering Information List of Models Relay and Socket Combinations 1 2 3 4 5 G2RV SL Classification Enclosure rating Input voltage Type of connection Contact form SPDT Plug in terminals General purpose Unsealed AC DC Screw terminals G2RV SL700 Push in terminals G2RV SL500 Input voltage Screw terminals Pu...

Страница 2: ... 500 VA 60 W Failure rate reference value 10mA at 5VDC P level Item 1 pole Contact resistance 100 mΩ max Operate set time 20 ms max Release time 40 ms max Max operating frequency Mechanical 18 000 operations hr Electrical 1 800 operations hr under rated load Insulation resistance 1 000 MΩ min at 500 VDC Dielectric strength 4 000 VAC 50 60 Hz for 1 min between coil and contacts 1 000 VAC 50 60 Hz f...

Страница 3: ...ions G2RV SL Series SPDT 12 to 48 VDC 24 to 230 VAC 250 VAC 6 A Resistive Load 30 VDC 6 A Resistive Load 400 VAC 2 A Resistive Load 6 000 Contact form Coil ratings Contact ratings Operations 1 pole 12 24 VDC 24 48 VAC DC 110 230 VAC 250 VAC 6 A Resistive Load 30 VDC 6 A Resistive Load 400 VAC 2 A Resistive Load 50 000 50 000 6 000 ...

Страница 4: ...ge VDC DC Breaking Current A Model number Operating time typical Release time typical G2RV SL7 5 DC12 5 7 ms 5 8 ms G2RV SL7 5 DC24 5 7 ms 6 9 ms G2RV SL7 5 AC DC24 5 7 ms 17 22 ms G2RV SL7 5 AC DC48 5 7 ms 22 30 ms G2RV SL7 5 AC110 12 15 ms 22 30 ms G2RV SL7 5 AC230 12 15 ms 22 30 ms Model number Description Connection P2RVC 8 O F PLC Output Interface for 8x G2RV SL700 series PNP type Ribbon cabl...

Страница 5: ... Cable length as indictad by model number length in centimeters Split into 4 sections Length 30 cm 40 Pole B A D C Control line AWG26 0 14 mm2 tin plated copper Diameter cable 10 6 mm one end splits into 4 sections A B C D Operating voltage 60 VDC Continuous current per signal wire 0 5 A Max total current 4 bytes each 1 0 A Test voltage 0 5 KV 50 Hz 1 min Operating temperature range 20 C to 50 C M...

Страница 6: ... VDC 21 VDC and 48 VDC List of Models Model number Cable length PLC type Configuration P2RV 200C SIM S7 300 2 0 m Siemens S7 300 4x1 Byte P2RV 250C SIM S7 300 2 5 m P2RV 300C SIM S7 300 3 0 m P2RV 500C SIM S7 300 5 0 m P2RV 200C SIM S7 400 2 0 m Siemens S7 400 4x1 Byte P2RV 250C SIM S7 400 2 5 m P2RV 300C SIM S7 400 3 0 m P2RV 500C SIM S7 400 5 0 m 1 2 3 4 5 6 G2RV Model number Replacement for G2R...

Страница 7: ...kers for G2RV Sockets Model number Poles Color P2RVM 020 2 Red R Blue S Black B P2RVM 030 3 P2RVM 040 4 P2RVM 100 10 P2RVM 200 20 Max current EN60947 7 1 section 8 3 3 1991 32A Max Voltage 400 VAC Max Voltage when cutting Cross bar without using separation plate or end bracket 250 VAC 1 2 P2RVM Model number Box quantity Color R99 15 for G2RV 1 piece 1 sheet 120 labels White Model number Box quanti...

Страница 8: ...lation between adjacent relays to achieve 400 V isolation 12 11 14 A1 A2 24 V DC Terminal Arrangement Internal Connections Top View 12 11 14 A1 A2 12 V DC Terminal Arrangement Internal Connections Top View 12 11 14 A1 A2 Other Coil Voltage Terminal Arrangement Internal Connections Top View Five M2 5 6 6 2 max 99 2 7 1 88 9 26 1 47 2 70 9 83 106 7 max 92 7 max 35 Input circuit ...

Страница 9: ...C Terminal Arrangement Internal Connections 12 11 14 A1 A2 Other Coil Voltage Terminal Arrangement Internal Connections Top View 6 2 max 99 2 88 9 7 1 24 6 46 69 8 82 9 106 7 max 97 4 max 35 Input circuit A2 A1 12 11 14 Terminal Arrangement Internal Connections Bottom View 30 5 max 3 5 0 5 2 4 1 8 5 2 max 5 04 5 04 3 22 33 max 16 2 Input circuit ...

Страница 10: ...n used as an exclusive tool Applicable Wires Applicable Wire Sizes G2RV SL700 Series Box clamp technology G2RV SL500 Series Push in technology Flat blade Parallel tip Flat blade Flared tip 2 5 dia 3 0 mm max Cannot be used Wire type Applicable wire size Stripping length Stranded without ferrules 0 5 2 5 mm2 7 mm Stranded with ferrules and plastic collar 0 5 2 5 mm2 7 mm Stranded with ferrules with...

Страница 11: ...d conductor into the connection hole No other tools are required Note In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire Screwdriver should be removed after fully insertion of the wire Removing Insert the specified screwdriver into the release hole Removing wire Removing screwdriver 7 mm Fig 1 Exposed Conductor Length 12 mm G2RV SL700 G2RV SL...

Страница 12: ...een dropped on the ground Dropping the product may adversely affect performance Confirm that the socket is securely attached to the mounting track before wiring If the socket is mounted insecurely it may fall and injure the operator Ensure that the socket is not charged during wiring and maintenance Not doing so may result in electric shock Do not pour water or cleansing agents on the product Doin...

Отзывы: