manualshive.com logo in svg
background image

1

READ AND UNDERSTAND THIS DOCUMENT

Please read and understand this document before using the products. Please consult your OMRON 
representative if you have any questions or comments.

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship 
for a period of one year (or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING 
NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE 
PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR 
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBL E FOR SPECIAL , INDIREC T, OR CONSEQUENTIA L 
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE 
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR 
STRICT LIABILITY. 

In no event shall responsibility of OMRON for any act exceed the individual price of the product on 
which liability is asserted. 

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS 
REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS 
WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO 
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED.  THEY ARE NOT 
DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED 
UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please 
refer to separate catalogs for OMRON’s safety rated products. 

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to 
the combination of products in the customer’s application or use of the product. 

At the custome r’s request , OMRON will provide applicabl e third party certificatio n document s 
identifying ratings and limitations of use that apply to the products. This information by itself is not 
sufficient for a complete determination of the suitability of the products in combination with the end 
product, machine, system, or other application or use. 

The following are some examples of applications for which particular attention must be given. This is 
not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that 
the uses listed may be suitable for the products: 

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions 
or uses not described in this document. 
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical 
equipment, amusement machines, vehicles, safety equipment, and installations subject to separate 
industry or government regulations. 
Systems, machines, and equipment that could present a risk to life or property. 

Please know and observe all prohibitions of use applicable to the products. NEVER USE THE 
PRODUCT S FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY 
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS 
THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR 
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

fz3_4ch_setup_E.book  Page 1  Friday, August 7, 2009  5:45 PM

Содержание FZ Series

Страница 1: ...ical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever nec...

Страница 2: ...ON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards cod...

Страница 3: ...ever disassemble apply pressure that would deform heat to 100 C or higher or incinerate the Controller Since this product emits a visible light that may have an adverse affect on the eyes do not stare...

Страница 4: ...50 C 122 F Provide a forced air fan cooling or air conditioning if the ambient temperature is near 50 C 122 F so that the ambient temperature never exceeds 50 C 122 F Do not install in this orientatio...

Страница 5: ...ediately after power is turned ON When using the RESET input to synchronize startup timing wait at least 15 second after the Controller s power supply is turned ON before turning ON the RESET signal M...

Страница 6: ...3 H900 10 FZ3 H905 10 Front view Touch pen standard accessory Right side view Controller Controller Monitor cable Recommended Model By OMRON Corporation S8VS 18024 Intelligent camera Automatic focus c...

Страница 7: ...cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 18024 Use the monitor to check images and display the condition...

Страница 8: ...232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available tr...

Страница 9: ...A max 1 1V max 5 ms max 0 7 ms max Input signals STEP0 ENCTRIG_Z0 STEP1 ENCTRIG_Z1 ENCTRIG_A0 to 1 ENCTRIG_B0 to 1 1 ON current ON voltage This refers to the current or voltage values needed to shift...

Страница 10: ...ltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay O...

Страница 11: ...2 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight i...

Страница 12: ...e Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controlle...

Страница 13: ...5 10 FZ3 700 10 FZ3 705 10 FZ3 H700 10 FZ3 H705 10 FZ3 900 10 FZ3 905 10 FZ3 H900 10 FZ3 H905 10 FZD 500 10 FZD 505 10 Box type FZ3 350 10 FZ3 355 10 FZ3 H350 10 FZ3 H355 10 FZ3 750 10 FZ3 755 10 FZ3...

Страница 14: ...ed When FZ S_ FZ SC_M FZ S_M is connected Approx 4 9 A max When FZ SF_ FZ SP_ is connected Approx 4 9 A max When FZ SLC___ FZ SZC___ is connected Approx 7 5 A max When FZD STC2M is connected Approx 4...

Отзывы: