Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
FQ2 User’s Manual
235
8
Co
ntro
llin
g Operatio
n an
d Ou
tp
utti
ng Da
ta
with a Parall
el Con
nection
• Create the ladder program to control the TRIG and IN5 input signals so that they do not turn ON while the BUSY
signal is ON. If not, a TRIG input error will occur and the ERROR signal will turn ON.
• Operation When the Sensor Power Supply Is Turned ON
The BUSY signal will operate as shown below when the Sensor’s power supply is turned ON.
Create the ladder program in the PLC or other external device so that the BUSY signal is ignored while it turns OFF,
ON, and OFF again for up to 5 s after the power supply is turned ON.
* Depends on the scene data.
Configuring the Operation
The following settings can be selected depending on the system configuration and application.
Setting the Measurement Trigger
The measurement trigger can be chosen from the following two types:
• One-shot measurement: One measurement is performed for each external trigger.
• Continuous measurement: Measurements are performed continuously.
You can mount a Parallel Interface Sensor Data Unit to enable using other signals and increase the number of sig-
nals that you can use with parallel communications.
And in addition to outputting OR judgement results, you can also use a Parallel Interface Sensor Data Unit to output
the judgement results of judgement conditions that you set for parallel output (called parallel judgement output) and
the results of measurement values and expressions for inspection items (called parallel data output).
8-2 Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit: p. 256
Type of change
Change
Reference
Changing the type of measurement trigger
Performing continuous measurements
Changing the output method of the judgement results
Obtaining individual judgement results
Adjust the judgement output timing
Changing the judgement output ON conditions
Changing the polarity of the BUSY output
Reversing the polarity of the BUSY signal
Changing the BUSY output condition
Adjusting the end timing of the BUSY signal
Changing the polarity of the output signals (OUT1 to
OUT3)
Reversing the output polarity of OUT1 to OUT3
Important
24
V
BUSY
O
N
OFF
0
V
1.5 s
3.5 s*
Sensor system is initializing
T
u
rns OFF
w
hen the
Sensor is ready for
operation.
Po
w
er s
u
pply
Note
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......