Inspecting with the Shape Search II Inspection Item
150
FQ2-S4 User’s Manual
Select the Results to Output
You can use multiple conditions to determine which results to output from all the objects detected with a
correlation at the candidate level or higher.
Only the results that meet all the specified conditions are output.
[Inspect]
−
[Inspection]
−
[Shape Search II]
−
[Modify]
−
[Details] Tab Page
−
[Meas.
Parameter]
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Shape Search II]
−
[Details] Tab Page
−
[Output
parameter]
1
Press [Extraction condition] and adjust the candi-
date level so that only objects higher than a certain
correlation are detected.
2
Set the conditions for outputting the detected ob-
jects.
(Extraction X/Y and Detection Count)
Extraction con-
dition
Range
Description
Candidate level 0 to 100
Defaults: Lower limit: 80, Upper limit: 100
Outputs only objects with a correlation that is higher
than the specified candidate level.
Extraction X
−
99999.9999 to 99999.9999
Defaults: Lower limit:
−
99,999.9999, Upper limit: 99,999.9999
Results are output only for objects with a measured X
coordinate that is within this range.
Extraction Y
−
99999.9999 to 99999.9999
Defaults: Lower limit:
−
99,999.9999, Upper limit: 99,999.9999
Results are output only for objects with a measured Y
coordinate that is within this range.
Detection
count
1 to 32
Default: 1
Sets the maximum number of detection results to out-
put.
The processing time changes if you change the candidate level.
Note
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......