Setting the Retry Function
422
FQ2-S/CH User’s Manual
7-11Setting the Retry Function
FQ2-S4
FQ2-CH
Retry Function
This function repeats the Scan (with a single measurement trigger) until the overall judgment is OK.
The retry function has four modes: normal retry, exposure retry (*1), scene retry, and trigger retry.
*1:
The brightness (exposure) depends on the shutter speed and gain. When HDR is ON, the shutter speed and gain are automatically
adjusted for the optimum exposure. When HDR is OFF, the gain is fixed.
(Setup
Mode)
−
[Sensor settings]
−
[Retry details]
−
[Retry mode]
1
Select the retry mode.
Retry mode
Description
Normal retry
This function repeats the Scan at the specified interval and count until the overall judg-
ment is OK.
Sets the repeat count and imaging interval.
These settings are set from Retry settings of each Scenes.
Exposure retry
Scanning is repeated the specified number of times while varying the exposure (when
HDR is OFF, the shutter speed is varied) until the entire code is successfully scanned.
The brightness step (shutter speed step when HDR is OFF), increment count, and decre-
ment count are specified. The settings are configured in the retry settings of each scene.
Scene retry
This function repeats the scan at the specified count while switching the Scenes until the
overall judgment is OK.
[Auto] or [Fixed] is selected for the switch order.
[Auto]: Switches through the scenes in the order of highest frequency of use.
[Fixed]: Switches scenes in the set order.
Trigger retry
This function repeats the reading procedure until the overall judgment is OK when IN5
signal of parallel is ON.
To use trigger retry, the I/O input mode must be set to expanded mode.
None (Default)
Retry is not performed.
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......