Calibration
FQ2-S/CH User’s Manual
369
7
Conven
ien
t Fu
ncti
ons
7-2 Calibration
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
Calibration
Calibration is used to convert Camera coordinates into actual coordinates.
You can set calibration to output the detected position in the actual coordinates.
You can convert pixels to actual dimensions and then output them.
You can also compensate for offsets in the origin and coordinate system.
• Calibration Conversion Methods
There are the following three conversion methods for calibration.
Point specification: You can enter the actual pixel coordinates of any position.
Reference: You can measure a registered model and then enter the actual coordinates of the model.
Parameter: You can enter the calibration values directly.
30 mm
540 pixels = 30 mm
Example
Origin of actual coordinates
Origin of Camera coordinates
Example
Camera coordinates
0
X
Y
Origin of
Camera
coordinates
Positive
direction
for angles
Origin of actual
coordinates
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......