F3UV
F3UV
5
J
MONITORS WITH FIBER
-
OPTIC CABLES
Amplifiers
Item
F3UV-XW11
F3UV-XW41
Power supply voltage
12 to 24 VDC
±
10%
Current consumption
75 mA max.
Outputs
Analog output
Current (4 to 20 mA) or voltage (1 to 5 V) (Monitoring mode or integral mode)
Outputs
Judgement output
NPN open collector output, 100 mA max.,
residual voltage 1 V max.
PNP open collector output, 100 mA max.,
residual voltage 2 V max.
Answer-back output
residual voltage 1 V max.
(Monitoring mode or integral mode)
residual voltage 2 V max.
(Monitoring mode or integral mode)
Inputs
Remote teaching input
ON: 0 V short-circuit (current 1 mA max.)
OFF: Open (open or 9 to 24 V)
ON: Power supply voltage short-circuit or 9 to
24 V (open-circuit current: 3 mA max.)
Reset input
OFF: Open (open or 9 to 24 V)
24 V (open-circuit current: 3 mA max.)
OFF: Open (open or 1.5 V max.)
Protective circuits
Reversed power supply polarity protection and output short-circuit protection
Response time (See Note 1)
500 ms max.
Sensitivity setting
Teaching function
Indicators
Power supply/Teaching indicator (green/red), Operation indicator (orange), 7-segment digital
percentage display (red), 7-segment digital threshold display (red)
Repetitive accuracy
±
2% Full Scale max.
Ambient operating illumination
(See Note 2)
Fluorescent light 1,000 lux max.
Temperature drift
±
0.1% of Full Scale /
°
C max.
Ambient temperature
Operating: --25
°
to 55
°
C (--13
°
to 131
°
F) with no icing or condensation
Storage: --40
°
to 70
°
C (--40
°
to 158
°
F) with no icing or condensation
Ambient humidity
Operating or storage: 35% to 85%
Insulation resistance
20 M
W
min. (at 500 VDC)
Dielectric strength
1,000 VAC 50/60 Hz between the leads and the case
Vibration resistance
10 to 150 Hz, 0.1-mm amplitude or 15 m/s
2
in X, Y, and Z directions each for 2 hours
Shock resistance
150 m/s
2
three times each in the X, Y, and Z directions
Degree of protection
Conforms to IEC 60529 standards IP30
Connection method
Pre-wired cable with a standard length of 2 m
Weight (packed)
Approx. 270 g (9.5 oz)
Material
ABS plastic
Accessories
Operation Manual
Note: 1.
The response time is the rise time or fall time of the output signal.
2.
The ambient operating illumination is the illumination that changes the analog 5% Full Scale at 200 lux; it is not the
operational limit.
3.
An analog output of up to 6 V (or 24 mA) can be output. The output is 1 V (or 4 mA) when there is no incident UV light.
4.
For a current output, full scale is 16 mA (4 to 20 mA). For a voltage output, full scale is 4 V (1 to 5 V).
5.
Definition of the luminous energy integral: The physical unit of the luminous energy integral is energy (J: joules) and this value
is calculated by multiplying the UV intensity (mV) by the time of exposure (s), but it is dimensionless when this sensor’s analog
output value (V) is used for the UV intensity. The integral is measured with an 11 ms sampling time.
Head Unit
Item
F3UV-HM
Incident light wavelength range
200 to 370 nm
Temperature drift
0.15%/
°
C max.
Ambient temperature
Operating or storage: --40
°
to 300
°
C (--40
°
to 572
°
F) with no icing or condensation
Ambient humidity
Operating or storage: 35% to 85% (with no icing or condensation)
Weight (packed)
Approx. 300 g (10.58 oz.)
Vibration resistance
10 to 55 Hz, 0.75-mm amplitude or 10 m/s
2
, approximately 1 G
Shock resistance
500 m/s
2
approximately 50 G
Material
Protective casing
Stainless steel (SUS303)
Material
Fluorescent fiber
path
Functional fluoroglass
Accessories
M8 nut and mounting bracket
Содержание F3UV Series
Страница 18: ...F3UV F3UV 18 J APPLICATION EXAMPLES...