81
F3SJ-A
User’s Manual
Ch
apt
e
r
3
Wi
ring
Wiring/Installation
E
Wiring Procedure
1.
Connect an emitter cable (F39-JC
-L, grey, sold separately) to the emitter's connection cable (grey).
2.
Connect a receiver cable (F39-JC
-D, black, sold separately) to the receiver's connection cable
(black).
3.
Connect the 0V line of the power supply directly to the protective earth (PE).
To ensure proper wiring, check that the color of the cable matches the color of the connector's resin cover (emitter: grey,
receiver: black). Failure to do so may result in damage to the F3SJ. Incorrect wiring can be prevented by matching the
colors.
Cable with connector on one end (F39-JC
A, sold separately)
Internal wiring diagram (F39-JC
A-L, F39-JC
A-D)
Set model name
For emitter
For receiver
L (mm)
F39-JC3A
F39-JC3A-L
Grey cable F39-JC3A-D
Black
cable 3000
F39-JC7A
F39-JC7A-L
F39-JC7A-D
7000
F39-JC10A
F39-JC10A-L
F39-JC10A-D
10000
F39-JC15A
F39-JC15A-L
F39-JC15A-D
15000
F39-JC20A
F39-JC20A-L
F39-JC20A-D
20000
15
39.5
L
8-wire (4-pair) (Cross section of conductor: 0.3mm
2
/insulator diameter: 1.15mm)
(Unit: mm)
Insulated vinyl round cable
6.6
M12 Waterproof connector
+24V DC
0V
N.C
+24V DC
0V
Female
White
Brown
Green
Grey
Pink
Blue
Red
Shield
Yellow
White
Brown
Green
Grey
Pink
Blue
Red
Yellow
Shield
Interlock selection input
Test input
Reset input
External device
monitoring input
Safety output 1
Safety output 2
Auxiliary output 1
Twisted pair wires are white and red, brown and blue, green and yellow, and grey and pink
Emitter
Receiver
Connected to connection cable and
Cable with connectors on both ends
Communication line (+)
Communication line (-)
Communication line (+)
Communication line (-)
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]