12
Chapter
1
Ra
tings
F3SJ-A
User’s Manual
Overview and Specifications
Indicators
Emitter
Incident light level indicators (green LED x 2, orange LED x 3): ON based on the amount of
incident light
Error mode indicators (red LED x 3): Blink to indicate error details
Power indicator (green LED x 1): ON while power is ON
Interlock indicator (yellow LED x 1): ON when in interlock/Blinks when in lockout
External device monitoring indicator (muting input 1 indicator), Test indicator (muting input 2
indicator) (green LED x2): ON/Blink according to function
Receiver
Incident light level indicators (green LED x 2, orange LED x 3): ON based on the amount of
incident light
Error mode indicators (red LED x 3): Blink to indicate error details
OFF-statet indicator (red LED x 1): ON when safety outputs are OFF/ Blinks when in lockout
ON-state indicator (green LED x 1): ON when safety outputs are ON
Muting error indicator, Test indicator (green LED x 2): ON/Blink according to function
Mutual interference prevention function
Interference light avoidance algorithm
Series connection
Time division emission by series connection
- Number of connections: Up to 4 sets
- Total number of beams: Up to 400
- Maximum cable length between 2 sets of sensors: 15m
For total extension length (
cable extension length
)
Test function
- Self-test (After power ON, and during operation)
- External test (light emission stop function by test input)
Safety-related functions
- Start interlock, restart interlock (Not usable when muting function is used)
- External device monitoring
- Muting (Includes override functions. F39-CN6 key cap for muting is required)
Connection method
Connector method (M12, 8-pin)
Protection circuit
Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature
During operation: -10 to 55°C (without freezing), During storage: -30 to 70°C
Ambient humidity
During operation: 35 to 85%RH (no condensation), During storage: 35 to 95%RH
Ambient light intensity
Incandescent lamp: receiving-surface light intensity of 3,000 Ix max., Sunlight: receiving-
surface light intensity of 10,000 Ix max.
Insulation resistance
20M
Ω
or higher (500VDC)
Dielectric strength voltage
1, 000VAC, 50/60Hz, 1min
Degree of protection
IP65 (IEC60529)
Vibration resistance
Malfunction: 10 to 55Hz, Multiple amplitude of 0.7mm, 20 sweeps each in X, Y, and Z
directions
Shock resistance
Malfunction: 100m/s
2
, 1,000 times each in X, Y, and Z directions
Connection cable, Series connection
cable (F39-JJR15L, JJR3W)
Dia. 6 mm, 8-wire (0.15mm
2
x 8) with braided shield, Allowable bending radius R5mm
Extension cable (F39-JC
A,
JC
B,JC
C)
Dia. 6.6 mm, 8-wire (0.3mm
2
x 4P, conductor resistance 0.058 ohm/m), with braided shield,
Allowable bending radius of R36mm.
(To extend a cable, use an equivalent or higher-performance cable, and do not use the cable
in the same duct as that for high-voltage cables or power cables)
For details about extension lengths (cable extension length)
For details about twisted pair wire (single connector cable)
Material
Casing (including metal parts on both ends): Aluminum, zinc die-cast
Cap: ABS resin
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
F3SJ-A
P14
F3SJ-A
P20
F3SJ-A
P30
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles