Specifications Table
-- continued from previous page
Part number
F3S-A161P F3S-A321P F3S-A481P
F3S-A082P F3S-A162P F3S-A242P F3S-A322P F3S-A402P F3S-A482P
Ambient
light
intensity
Incan-
descent
lamps
3,000 lx max. (receiver surface light intensity)
y
Sunlight
10,000 lx max. (receiver surface light intensity)
Insulation resistance 20 M
Ω
min. at 500 VDC
Stabilization on
powerup
5 seconds
Dielectric strength
voltage
1,000 VAC 50/60 Hz for 1 min
Degree of protection IEC60529 IP64
Vibration resistance
Durability: 10 to 55 Hz, double-amplitude: 1.5 mm, X, Y and Z axes: For 2 hours
Operation limit: 10 to 55 Hz, double-amplitude: 0.7 mm, X, Y and Z directions: For 50 min. (See Note 3.)
Shock resistance
Durability: 300 m/s
2
[30 G], X, Y and Z directions: 3 times
Operation limit: 100 m/s
2
[10 G], X, Y and Z directions: 1,000 times (See Note 3.)
Cable (See Note 4.)
Emitter and receiver: 8 conductors (0.3 mm
2
x 4 conductors, 0.2 mm
2
x 4 conductors), external dimension: 6
mm in diameter with spiral shield, allowable bend radius R36 mm, attached cable: 400 mm length
Materials
Case: Aluminum
Front cover: PMMA (acrylic resin)
Cable: PVC
Accessories
Test rod, mounting brackets (top and bottom), mounting brackets (intermediate) for the F3S-A32 and F3S-A482
only, Instruction Manual
Applicable standard
prEN50100-1 TYPE 4 ESPE and prEN50100-2 TYPE 4 AOPD
Note: 1. The logic (ON/OFF) may differ from that normally used because a safety circuit is used. Be sure to check this carefully.
2. Lock-out: Output status OFF due to unrecoverable failure. OFF-hold: Output status OFF due to temporary failure.
3. In accordance with prEN50100-1
4. The optional extension cord provides the same cable specifications.
(Reference) Resistance: Power line and output line: 66.3
Ω
/Km
Sync line: 94.0
Ω
/Km
Use a cable of at least the same performance to extend the cable length. The total cable length must be 100 m or less.
n
2
1
No. of optical axes
Detection distance
Protective
height
E
m
itter
Re
ce
ive
r
Beam spacing
J
STANDARDS APPLICABLE TO THE USE OF F3S-A
US Standards
OSHA 29 CFR 1910.212
OSHA 29 CFR 1910.217
ANSI B11.1 to B11.19
ANSI/RIA 15.06
EN Standards
EN954-1 Category B, 1, 2, 3, 4